Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:06LTM0075A
 
 
Part:06LTM0075A
Description:Transducer Disp
Company:
Datasheet:Download 06LTM0075A datasheet   File size : 29 kB
Request For quote:  Find where to buy 06LTM0075A
 



Datasheet text preview:
MODELS LT/MLT ·
TECHNICAL SPECIFICATIONS
MODELS

LINEAR POSITION TRANSDUCER

LT

MLT

DIPTEONS** S O M I NSION

MECHANICAL
Total Mechanical Travel Starting Force Shock Vibration Life 1.05 to 10.05 in. (min) 26.7 to 255.3 mm (min) .55 to 6.05 in. (min) 13.9 to 153.7 mm (min)

1.0 oz (max) 50 g 11 ms half sine 20 g rms 5 Hz to 2 KHz (MLT only) One billion dither operations

· Other resistance values · Independent Linearity to ± .1% Travels > 1 inch* · Water resistant seal*** · Three pin connector for MLT
DIMENSIONS
.50 Dia. (12.7) Housing length (Electrical travel + 1.50 in.) 1.00 (Retracted) (25.4) .125 Dia. (3.1)

ELECTRICAL
Theoretical Electrical Travel (in 1" increments) Independent Linearity Total Resistance Resistance Tolerance Operating Temperature Resolution Insulation Resistance Dielectric Strength Power Rating Recommended Wiper Current 0.25 Watt/in. electrical travel <1µA
.375 Dia. (9.53) 3 - Conductor cable #26 AWG (65/44) 12" (305) long min. (Color coded per schematic) xx.xx = inches (xx.xx) = mm (Black) Ground .187 Dia. (4.76) .50 (12.7) .75 Retracted (19.05) (Red) V-in Shaft Extended

1 to 10 in. (25.4 to 254.0mm) ±1.0% 1000 /in. electrical trave ±20%

1/2 to 6 in. (12.7 to 152.4mm)

#4-40 UNC-2A Thd x .50 in. long #28 jacketed cable 6" long, min. (Color coded per schematic) xx.xx = inches (xx.xx) = mm

1500 /in. electrical travel

(Black) Ground

(Red) V-in Shaft Extended

-40° to 80°C (-40° to 176°F) Infinite 1000 M @ 500 Vdc 500 M @ 500 Vdc 1000 V rms 0.20 Watt/in. electrical travel

(Brown) V-out Connect to high impedance circuit

SCHEMATIC DIAGRAM

Housing length [Electrical travel +1.2" (30.48)]

.063 (1.6) .125 Dia. (3.1)

#4-40 UNF-2B

(Orange) V-out Connect to high impedance circuit

SCHEMATIC DIAGRAM
.17 (4.3) .125 (3.17) .25 (6.35) Wiper M6 x 3 Thread #4-40 UNF-2B .625 (15.87) .37 (9.4)

Extended (Red)

Retracted (Black)

Optional MLT connector

Metric Shaft Adapter

.32 (8.0) .75 (19.0)

*5-95% of Theoretical Electrical Travel **Minimum quantities may be required. ***LT only, 12 oz. (340 g) max. starting force NOTE: Do not test using an Ohmeter on Rx 1 scale or other current devices. Excessive wiper current can cause output error or damage. Zero side load is recommended to achieve maximum life.

MLT Mating Connector

s
1-800-333-DATA
23