Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: 6-1393215-7

Category:
 Discrete
   -> Solid State relays

Description: Relay PCB 12vdc

Company:

Datasheet: Download 6-1393215-7 datasheet     File size : 185 kB

Request For quote: Find where to buy 6-1393215-7



Datasheet text preview:
Card Relay E (KRE)

V23057

PCB relay for DC voltage, neutral, monostable
Features
q

Design
­ Flat or upright versions with 1 changeover contact or 1 make contact or 1 break contact Changeover contact assembly with single or double contacts For printed circuit assembling Immersion cleanable

Used as a switching element for electrical separation between low-power control circuits and power load circuits Clearance/creepage distances between winding and contact 4 mm (A/B version, make contact or changeover contact) or 8 mm (C/D version, make contact or break contact) Mechanical and electrical characteristics comply with the "Rules for electrical relays in power installations" (VDE 0435/9.72) Used for safe electrical insulation in the following applications ­ open and closed-loop control equipment for domestic use (VDE 0631) ­ electronic equipment for domestic use (VDE 0860) Suitable for fully automated processing

q

­ ­ ­

q

q

q

Approvals
VDE

Typical applications
q q q q

VDE SEV CSA UL

Mark of conformity 91.1 12262.04 File LR 89731 File E 48393

5146

Machine tool control Interface modules Timer relays Elevator controls

Siemens AG3

Card Relay E (KRE)

Dimensional drawing (in mm)
Flat version

ECR0975-B

Mounting hole layout
View on the terminals

Approx. 1:1 scale

Terminals in a 2.5 mm and 2.54 mm basic grid to EN 60097 and DIN 40803, fine

Terminal assignment
View on the terminals

Changeover contact Clearance/creepage dist. S 4 mm

Make contact Clearance/creepage dist. S 4 mm

Break contact Clearance/creepage dist.S 8 mm

Make contact Clearances/creepage dist. S 8 mm

4

Siemens AG

Card Relay E (KRE)

Dimensional drawing (in mm)
Upright version

ECR0975-A

Approx. 1:1 scale

Mounting hole layout
View on the terminals

Terminals in 2.5 mm and 2.54 mm basic grid to EN 60097 and DIN 40803, fine

Terminal assignment
View on the terminals

Changeover contact Clearance/creepage dist. S 4 mm

Make contact Clearance/creepage dist. S 4 mm

Break contact Clearance/creepage dist. S 8 mm

Make contact Clearance/creepage dist. S 8 mm

Siemens AG5

Card Relay E (KRE)

Contact data
Contact category III according to VDE 0435 Part 120/10.81 B Ordering code, block 3/ No. of contacts and type/ contact assembly Ordering code, block 3/ No. of contacts and type/ contact assembly Contact material Max. continuous current at max. ambient temperature Inrush current (max. 4 s for 10% duty cycle) Maximum switching voltage Maximum switching capacity AC voltage DC voltage Recommended for loads > Contact resistance (initial value)/measuring current/driver voltage Note: 1 mA, 6 V­ 100 m/100 mA/6 V A101 A102 A103
1 break

A201

A202 Single contacts

A203
1 break

A401

A402

A403
1 break

1 change. 1 make

1 change. 1 make

1 change. 1 make

B101
1 change.

­ ­ AgNi0,15 gold-flashed

­ ­

B201
1 change.

­ ­ AgNi20 8A 15 A 440 V~ 300 V­

­ ­

B401
1 change.

­ ­ AgCdO

­ ­

Double contacts

2000 VA See load limit curve 100 mA, 12 V~/V­ 100 m/100 mA/12 V 500 mA, 12 V~ 100 m/1A/24 V

Other contact materials and hard gold-plated contacts available on request

Load limit curve
for relays with single contacts

Load limit curve
for relays with double contacts

I = switching current U = switching voltage Curves: Safe shutdown, no stationary arc > 10 ms. Max. 12.5 operations/s.

Curve 1 ­­­­­­­ Curve 2 ­ ­ ­ ­ ­

Contact material silver, gold-flashed Contact material silver cadmium oxide

6

Siemens AG

Card Relay E (KRE)

Coil data
Nominal voltages Nominal power consumption, typ. Maximum pull-in power Minimum release voltage From 6 V­ to 60 V­ Special voltages on request 450 ... 500 mW 240 mW 10 % of nominal voltage

Coil versions
Nominal voltage Unom V­ 6 12 24 48 60 Operating voltage range at 20 °C Operate voltage UI V­ 4 .2 8.3 16.8 33.6 42.0 Max. voltage UII V­ 10.6 21.5 40.0 79.0 98.0 80 ± 330 ± 1200 ± 4700 ± 7200 ± Resistance at 20 °C 8 33 180 700 1080 001 002 006 013 023 Number of coil Ordering code, block 2

Other coil versions available on request Data for operating range and class of operative range according to DIN IEC 255 Part 1-00/VDE 435 Part 205 available on request

UI UII

= Operate voltage at 20 °C after pre-energizing with UI without contact current = Maximum continuous voltage at 20 °C for Tc max = 115 °C without contact loading kI

Operating voltage limits UI and UII depend on temperature and can be calculated by:

UI tamb = kI · UI 20 °C and UII tamb =kII· UII 20 °C tamb = UI tamb = UII tamb= kI a. kII = Tc max =
Ambient temperature Minimum voltage at ambient temperature tamb Maximum voltage at ambient temperature tamb Factors (dependent on temperature), see diagram Maximum coil temperature

kII

Ambient temperature tamb

Siemens AG7




Others parts begin by 60
60-1   60-2