Part: 73-560-0095
Category:
Description: Psu 600w 4 O/p
Company:
Datasheet: Download 73-560-0095 datasheet File size : 843 kB
Request For quote: Find where to buy 73-560-0095
Datasheet text preview:
MVP Series
400 - 1000 Watts
SPECIAL FEATURES
· Current share on all main outputs with ratings of 10 A or greater · Remote sense on all outputs with ratings greater than 2 A · Overload protection on all outputs · Voltage adjustment on all outputs · Margining on all single output modules · Input-OK-signal and status indicator LED · Global DC OK signal and status indicator LED · Global and individual module inhibits/enable · 1 year warranty · Forced air cooling, field replaceable fan · Isolated 5 V bias voltage · Power factor correction · IEC EN61000-3-2 harmonic distortion compliance · CISPR 22, EN55022 Curve B conducted / radiated EMI · IEC 801 immunity standards · European CE Mark requirements · Optional VME timing and system DC OK module · Low leakage option for medical applications
MP4........400 W total
MP6........600 W total
E N V I R O N M E N TA L
Operating temperature: -20°C to 50°C (start @ 0°C) (derate each output linearly to 50% at 70°C) (-20°C to 40°C max. with rear air option) Shock/Vibration: Mil-Hdbk 810E Humidity: 95% non-condensing Storage temperature: -40°C to +85°C Temperature coefficient: 0.02% per °C Cooling: Internal DC fan (Field replaceable) (P/N 73-688-0001)
MP8........800 W total
SAFETY
UL CSA IEC VDE BABT CB CE UL1950 E133211 CSA22.2 No. 234 Level 5 LR53982 IEC950, Class 1 EN60950 11774-3336-xxxx Compliance to EN 60950, BS 7002 Certificate and report Mark
MP1........1000 W total
80
USA: 1-888-41-ASTEC
Europe (UK): 01384-842211
Asia (HK): 852-2437-9662
ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426
ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355
ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
E L E C T R I C A L S P E C I F I C AT I O N S Input
Input voltage...85-264 VAC 120-350 VDC Frequency ......47-440 Hz Inrush current.......40 A peak max. Efficiency........70-80% typ. @ full case load Power factor ...0.99 typ. meets EN61000-3-2 Turn-on time ...AC on 1.5 sec typ., Inhibit / Enable 150 ms typ. EMI filter standard .........CISPR 22 EN55022 Level "B" EMI filter (low leakage option)...CISPR 22 EN55022 Level "A" Leakage current standard ......2.0 mA max. @ 240 VAC Leakage current (low leakage option)......300 µA max. @ 240 VAC Radiated EMI .......CISPR 22 EN55022 Level "B" Holdover storage...........20 ms minimum (independent of input VAC) AC OK...>5 ms early warning min. before outputs loose regulation Full cycle ride thru (50 Hz) Harmonic distortion .......Meets EN61000-3-2 Isolation..........Meets EN60950 Global Inhibit/Enable .....TTL, Logic "1" and Logic "0" Input fuse (internal) .......MP4: 10 A MP6: 15 A MP8: 20 A MP1: 20 A Warranty.........1 year
Output
Adjustment range ..........±10% min. all outputs Margining .......±4-6% nom.1 Overall reg......0.4% or 20 mV max. (36 W modules 4% max.) Ripple....RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz Dynamic response ........5 ms warning (AC OK signal) before shutdown Remote sense ......Up to 0.5 V total drop Single wire parallel........Current share to within 2% of total rated current 2 DC OK...-2% to -8% of nominal for any monitored output 2 Minimum load.......Not required on single or triple output modules. 10% required on main of dual output modules 3 (Consult factory if pre-loaded required) Housekeeping Bias voltage ...5 VDC @250 mA max. present whenever AC input is applied Module inhibit.......TTL, isolated, singles and dual (both outputs) only Switching frequency......250 kHz Output/Output isolation ..........>1 Megohm
Notes: 1 Single output modules only. 2 Single and main of dual output modules only. 3 Contact factory for optional preload if required.
Power Fax: 760-930-0881
Doc No: 1058 · REV 1.6.99
81
Common Examples and Specifications
Slot #1 Slot #2 Slot #3
Case Size (inches): 4 = 2.5 x 5 x 10, 5 available slots, 400 W max. 6 = 2.5 x 5 x 11, 5 available slots, 600 W max. 8 = 2.5 x 7 x 10, 6 available slots, 800 W max. 1 = 2.5 x 8 x 11, 7 available slots, 1000 W max. (MP8 & MP1 Only) Slot #6
Option Code: 0 = no options 1 = rear air exhaust 3 = global enable 5 = option package (options 1 & 3) M =low leakage N = low leakage plus option 1 P = low leakage plus option 3 R = low leakage plus option 5 (MP1 Only) Slot #7
Slot #4
Slot #5
MP
-
-
-
-
-
-
-
-XXX
Use Only for Modified Standard Contact Astec.
2 or 3 Digit Code See Output Currents Next Page
Use " -- " for Standard Remote Sense Use " / " After any module using Remote Sense with o-ring diode (redundancy)
Notes: 1 Omit digits that do not apply. 2 Specify modules from lowest number of outputs to highest.(Single/Dual/Triple) 3 If number of outputs are equal, specify modules from highest to lowest power increments. If power increments are equal, specify in decending alphabetical order (1A, B, C...). 4 Always start with Slot 1. 5 All MVP model configurations created using this selection guide are standard MVP products with standard availability and lead times.
Parallel Code:
MP4 & MP6
available slots
MP8
available slots
MP1
available slots Standard Parallel Codes* 0 = no parallel 1=1&2 2=2&3 3=3&4 4=4&5 5=3&4&5 6=5&6 7=4&5&6 8=6&7 9 = 3 & 4, 6 & 7 *For custom parallel configurations, contact Astec. 7 6 54 3 2 1
Ordering Example:
2.5" x 5" x 11" (5 slots available) Slot 3 Output 2: 12 V @ 17 A Slot 5 Output 5: 12 V @ 1 A Output 6: 12 V @ 1 A Output 7: 5 V @ 2 A
MP6-
2F/1L-4LE-LLE-0M
Low Leakage No Paralleling
Slots 1 & 2 Slot 4 Output 1: 5.2 V @ 60 A Output 3: 12 V @ 10 A Output 4: 5 V @ 10 A
COMMON EXAMPLES OF MODEL NUMBERS
SINGLE OUTPUTS
Total Power 360 W 400 W 600 W 600 W 600 W 800 W 800 W 1000 W Output (Volts/Amps) 2 / 180 5 / 80 2 / 275 5 / 120 48 / 12.5 5 / 160 48 / 16.6 5 / 200 Size (inches) 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 8 x 11 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 8 x 11 Model Number
MP4-3A-2A-30 MP4-3E-00 MP6-3A-3A-1A-90 MP6-3E-00 MP6-3W-00 MP8-3E-2E-30 MP8-3W-1W-30 MP1-3E-3E-30
Slot 1
MULTIPLE OUTPUTS
Total Power 400 W 400 W 400 W 400 W 600 W 600 W 600 W 800 W 800 W 800 W 800 W 1000 W Output 1 (Volts/Amps) 5 / 60 24 / 15 5 / 60 5 / 35 3 / 60 5 / 120 12 / 30 36 / 16.6 5 / 120 15 / 20 2 / 180 3.3 / 120 Output 2 (Volts/Amps) 3.3 / 35 12 / 17 12 / 17 12 / 10 5 / 60 12 / 17 5 / 35 24 / 4 3.3 / 35 5 / 35 5 / 60 5 / 120 Output 3 (Volts/Amps) 12 / 1 5 / 35 12 / 10 3.3 / 10 12 / 10 12 / 10 -- 5 / 10 12 / 17 15 / 14 -- -- Output 4 (Volts/Amps) 12 / 1 -- 5 / 10 12 / 1 12 / 4 5 / 10 -- 12 / 10 12 / 10 24 / 8.5 -- -- Output 5 (Volts/Amps) 12 / 1 -- -- 12 / 1 -- -- -- 12 / 4 12 / 4 15 / 8 -- -- Output 6 (Volts/Amps) -- -- -- 5/2 -- -- -- -- -- 5 / 10 -- -- Size (inches) 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 10 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 5 x 11 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 7 x 10 2.5 x 8 x 11 Model Number
MP4-2E-1D-LLL-00 MP4-2Q-1L-1E-00 MP4-2E-1L-4LE-00 MP4-1E-4LD-LLE-00 MP6-2C-2E-4LL-00 MP6-3E-1L-4LE-00 MP6-2L-1E-00 MP8-3U-4QE-4LL-00 MP8-3E-1D-1L-4LL-00 MP8-2N-1E-1N-1Q-4NE-00 MP8-3A-2A-2E-30 MP1-3D-3E-00
82
USA: 1-888-41-ASTEC
Europe (UK): 01384-842211
Asia (HK): 852-2437-9662
ASTEC ASIA 6F., China Dyeing Works Building 382-392 Castle Peak Road Tsuen Wan, N.T., Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426
ASTEC EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 01384-842211 Facsimile: 01384-843355
ASTEC AMERICA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
OUTPUT CURRENTS
Voltage Voltage Code 1 2V 2.2 V 3V 3.3 V 5V 5.2 V 5.5 V 6.0 V 8.0 V 10 V 11 V 12V 14 V 15 V 18 V 20 V 24 V 28 V 30 V 33 V 36 V 42 V 48 V 54 V 60 V Non-std 2.4V - 27V 3.6V - 4.5V 6.6V - 7.2V 8.8V - 9.0V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 35A 35 A 35A 35 A 35A 35 A 34 A 23 A 20 A 18 A 17 A 17A 12.5 A 14 A 11 A 10.5 A 8.5 A 6.7 A 6.5 A 6.2 A 5.8 A 4.2 A 4.0 A 3.7 A 3.5 A 135 35 20 18 Single Output Module Code 2 60 A 60 A 60 A 60 A 60 A 60 A 58 A 42 A 36 A 32 A 31 A 30 A 21 A 20 A 19 A 18 A 15 A 12.8 A 12 A 10.9 A 10 A 7.5 A 7.5 A 6.0 A 6.0 A 60 60 36 32 3 120 A 120 A 120 A 120 A 120 A 115 A 109 A 78 A 68 A 60 A 54.5 A 50 A 40.5 A 39 A 33.3 A 30 A 23.5 A 21.4 A 20 A 18.2 A 16.6 A 12.5 A 12.5 A 11 A 10 A 120 120 68 60 V1 -- -- -- -- 10 A -- -- -- -- -- -- 10 A 9A 8A -- -- 4A 3A -- -- -- -- -- -- -- -- -- 10 10 Dual Output V2 10 A 10 A 10 A 10 A 10 A 10 A 10 A 10 A -- -- -- 4A 4A 4A -- -- 2A 2A 1.5 A 1.5 A 1.5 A -- -- -- -- 10 10 4 4 V1 -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Triple Output V2 -- -- -- -- -- -- -- -- 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- -- -- -- -- V3 2A 2A 2A 2A 2A 2A 2A 2A 1A 1A 1A 1A 1A 1A 0.5 A 0.5 A 0.5 A 0.5 A -- -- -- -- -- -- -- 2 2 1 1
Notes: 1 Takes up one slot. 2 Takes up two slots. 3 Takes up three slots.
S i n g l e Output Example 5 V @ 60 A
D u a l Output Example 1 12 V @ 10 A; 5 V @ 10 A
Module Code (always 4) Voltage Code
T r i p l e Output Example 1 12 V @ 1 A; 20 V @ 0.5 A; 5V@2A
Module Code
Voltage Code
2E
4LE
Notes: 1. Total Loading not to exceed 144 W.
LPE
Voltage Code2
Notes: 1. Total Loading not to exceed 36 W. 2. No Module Code required.
PFC INPUT
J1 CONTROL CONNECTOR
Pin No. J1-1 J1-2 J1-3 J1-4 J1-5 J1-6 J1-7 J1-8 J1-9 J1-10 Function Input AC OK - "Emitter" Input AC OK - "Collector" Global DC OK - "Emitter" Global DC OK - "Collector" Spare Global Inhibit/Optional Enable Logic "0" Global Inhibit/Optional Enable Logic "1" Global Inhibit/Optional Enable Return SELV 5V Housekeeping SELV 5V Housekeeping Return
DC/DC CONV ERTER OU TPU T MODU LES
CONTROL SIGNAL INFORMATION, J1 CONTROL CONNECTOR
Pin No. 1 2 3 4 5 6 7 8 9 10 Function + Remote Sense Remote Margin / V. Program Margin High - Remote Sense / Margin Low Spare Module, Isolated Inhibit Module Inhibit return Current Share (SWP) + Remote Sense V2 - Remote Sense V2 single or dual o/p main single o/p single o/p single or dual o/p main single or dual o/p single or dual o/p single or dual o/p main dual o/p, single is spare dual o/p, single is spare
Power Fax: 760-930-0881
Doc No: 1058 · REV 1.6.99
83
MVP Series
400 - 1000 Watts
D R AW I N G S · M V P S E R I E S M P 4 ( 4 0 0 W AT T S M A X ) A N D M P 6 ( 6 0 0 W AT T S M A X )
5-Inch Case Size: MP4: 2.5" x 5" x 10" (63.5mm x 127mm x 254mm) 5-Inch Case Size: MP6: 2.5" x 5" x 11" (63.5mm x 127mm x 279.4mm) Weight: MP4 Case: 2.6 lbs. · MP6 Case: 3.2 lbs. · 36 W Triple: 0.5 lb. 210 W Single: 0.6 lb. · 360 W Single 1.0 lb. · 600 W Single: 2.0 lbs. 144 W Dual: 0.6 lb.
NOTES
1. Input: Barrier type. Three No. 6-32 B.H. screws (0.375" centers). Max torque: 6 in-lbs. (0.67 N-m). 2. Control connectors: (J1 and J2) 10 position housing, gold plated contacts. Mates with Molex 90142-0010 housing with 90119-2110 crimp contacts (Molex C - Grid III Series) or AMP Model number 87977-3 with 87309-8 pins. Connector kit includes mating connector and 10 pins, Astec part #70-841-004. 3. Chassis material: aluminum with chemical film coating. (Conductive) 4. All dimensions are in millimeters and inches and are typical. 5. Customer mounting -3 sides M4, bottom also includes 8-32 mounting holes. Max. penetration is 0.150" (3.8mm). Max. torque: 5in-lbs. 6. Output module connections: All single O/P modules are M4 x 8mm screws. Max. torque: 10in-lbs. Dual O/P module is M3 x 8mm screws. Max. torque: 5 in-lbs. Triple O/P module is .045" square pins on .156" centers. (Mates with Molex 09-50-8063 or equivalent.)
84
USA: 1-888-41-ASTEC
Europe (UK): 01384-842211
Asia (HK): 852-2437-9662
Others parts begin by 73