Part: EL-1-12BIT
Category:
Description: Logger Data Panel Mount
Company:
Datasheet: Download EL-1-12BIT datasheet File size : 254 kB
Request For quote: Find where to buy EL-1-12BIT
Datasheet text preview:
®
EL-1-12BIT
WINDOWSTM Compatible Data Logger
EL-1-12BIT is an easy to use display module capable of measuring, recording, displaying and controlling temperature (Pt 100), voltage and current. With 12 bit A/D resolution, a memory for 8000 readings and a battery life of up to 3 years, EL-1-12BIT can operate as a 'stand alone' logger or be permanently connected to a system. The EL-1-12BIT serial link is addressable and up to 8 loggers can be connected to one serial port. The PC software operates under Windows and does not require specialist skill to operate. Data output is in text format and can be easily integrated into most popular spreadsheets. Graphical output is possible under EL-WIN. Consult the EasyLog software manual for further details.
Battery Powered Multi-function Non-volatile Data Storage Panel Mounting Easy to Use
High Resolution Read-out
°C
CONTROL SOFTWARE
Stock Number - EL-WIN
Easy to install and use, the control software will run under Windows 95 or 3.1 and enable the user to control one or more EasyLogs, operating them as a complete system. Supplied on a 3½" disk with a manual and serial link. Data Logger
Stock Number
-200 to +200°C 0.1°C ±0.5°C -200 to +200 °F 0.1°F ±1°F -200 to +850°C 1°C ±1°C -328°F to +1562°F 1°F ±2°F 0 to ±200mV 100µV 0 to ±2V 1mV ±0.05% 0 to ±20V 10mV 4 to 20mA 16µA ±0.1% 3.6V ½AA lithium (up to 3 years life) ** 8 Pin Mini DIN Screw terminal Up to 8000 samples** 1 sample per 5 seconds to 1 per 12 hours.
Specification
Temperature - Low Range * Temperature - High Range * Voltage - D.C. Current - D.C. Battery Serial link Sensor connection Memory Sample rate * Sensor dependent Input Impedance
Range
Resolution
Accuracy
EL-1-12BIT
ACCESSORIES - CABLES
Stock Number - EasyLink
Extension cable to 'daisy chain' more than one EasyLog. One extension will be needed for each extra EL-1-12BIT module that is attached to the chain.
SENSOR SOURCING GUIDE
Sensor
Temperature (Pt100) Humidity (%RH)
**Depending on sample rate 200mV Range 2V, 20V Range 4-20mA Range >1G 0.5M 10
Stock Number
PT-TYPE PROBE RH PROBE
DIMENSIONS All dimensions in mm (inches)
58.0 (2.28) 55.0 (2.16) 46.5(1.76)
1.5 1.6 (0.05) (0.06)
16.0 (0.63)
30.0 (1.18)
25.0 (0.98)
44.0 (1.73)
a
Ø2.50 (0.10)
1.1 (0.044)
17.8 (0.70)
9.0 (0.35)
6.1 (0.24)
12.8 (0.50)
2.00 (0.08)
64.5 (2.54) 46.5 (1.83) 1.0 (0.04)
Panel cut-out 62 x 32 (2.44 x 1.26)
2.50 (0.09)
5.2 (0.20) 31.8 (1.25)
34.5 (1.36)
18.0 (0.69)
LASCAR ELECTRONICS LTD. MODULE HOUSE, WHITEPARISH, WILTSHIRE. SP5 2SJ UK TEL: ++44 (1794) 884567 FAX: ++44 (1794) 884616
LASCAR ELECTRONICS INC. PO BOX 8204, SAVANNAH, GA 31412 USA TEL: ++1 (912) 234 2048
FAX: ++1 (912) 234 2049
Lk1: Lk2 & Lk3:
LINK FUNCTIONS
When daisy-chaining EasyLog Modules, remove the Lk1 jumpers from all modules except one. Fit these jumpers as shown in the table below. Measurement Range Jumper 200mV 2V 20V 4-20mA Temperature (Low Range) Temperature (High Range) Link Setting Lk 2 o p e n , Lk 3 O p e n Lk2 c l o s e d , Lk 3 o p e n Lk2 c l o s e d , Lk 3 o p e n Lk 2 o p e n , Lk 3 c l o s e d Lk 2 o p e n , Lk 3 o p e n Lk 2 o p e n , Lk 3 o p e n
PIN FUNCTIONS
TxD, RxD: SW: AV+: V-, V+: HA, LA V IN-, V IN+: Iin, Iout:
No pins fitted. Input and output connections for Infra-Red communications, e.g.: connect to a PANEL -IR module. Switch input, nor mally pulled high. Connect momentarily to V- to take a reading in One-Shot Rear Pin Header mode or to start logging when configured for Push-to -Start in EL -WIN. Test pin. Do Not Use. Exter nal power supply connections. Read Important Note below prior to use. RxD TxD Exter nal supply voltage range 3 to 3.6Vdc. Exter nal power supply must be floating with AV+ SW respect to the signal to be measured. V+ VNor mally at V-, these pins go high when their respective alar m levels have been reached LA HA or exceeded. VIN+ VINMeasurement Inputs, extension of screw ter minal block connections. Iout RS Iin Cur rent Loop connection, extension of screw ter minal block connections. Always remove the Lithium batter y from the module BEFORE connecting an exter nal power supply to the module. Failure to do so may cause the batter y to explode.
IMPORTANT NOTE-
BATTERY REPLACEMENT
MANUFACTURER MAXELL SAFT SONNENSCHEIN TADIRAN
Only use ½AA 3.6V lithium. The list below is not exhaustive. Check with supplier that the batter y you are ordering is 'press fit' and is not fitted with solder tags. Take care to connect cor rectly. DO NOT PRESS ON LCD WHEN INSERTING BATTERY. PART NUMBER ER 3S TC LS3 SL-750/S ½AA/S MANUFACTURER'S ORDER CODE n/a n/a 1107 501 100 1551-02-210-000
WARNING: Handle lithium batteries carefully - observe warnings on battery casing. Dispose of in accordance with local regulations.
APPLICATIONS
NOTE -It is possible to measure parameters other than those outlined below. Use an appropriate sensor and conditioning circuit to convert the parameter to be measured into a linear voltage or current and apply this signal to a suitably scaled EL-1-12BIT module. Measurement signals must always be isolated from the communications signals.
TEMPERATURE
red white
VOLTAGE
Vin- (R) Vin+ (W) Iout (W) Iin (R) 200mV DC connection (Lk2 and Lk3 open)
CURRENT
Vin- (R) Vin+ (W) Iout (W) Iin (R) 4-20mA Indication Use 4-20mA indication range (default calibration 0-1000) (Lk2 open, Lk3 closed) Vin- (R) Vin+ (W) Iout (W) Iin (R)
Vin- (R) Vin+ (W) Iout (W) Iin (R)
2-wire Pt100 connection (Lk2 and Lk3 open)
red
white white
Vin- (R) Vin+ (W) Iout (W) Iin (R)
Vin- (R) Vin+ (W) Iout (W) Iin (R) 2V DC connection (Lk2 closed, Lk3 open)
1R
3-wire Pt100 connection (Lk2 and Lk3 open)
200mA DC connection Use 200mV range with annunciators set to mA. Module will require calibration. (Lk2 and Lk3 open) Vin- (R) Vin+ (W) Iout (W) Iin (R)
red red
white white
Vin- (R) Vin+ (W) Iout (W) Iin (R)
Vin- (R) Vin+ (W) Iout (W) Iin (R) 20V DC connection (Lk2 closed, Lk3 open)
R
4-wire Pt100 connection (Lk2 and Lk3 open)
For higher ranges, use 200mV range and R= 0.2 I where I = 2A or 20A fsd. Module will require calibration. (Lk2 and Lk3 open)
Specifications liable to change without prior warning
EL-1-12BIT
Issue 2
March/1999
M.C.
Applies to EL-1-12BIT/2
Others parts begin by el
EL-1 EL-2 EL-3 EL-4 EL-5 EL-6 EL-7 EL-8 EL-9 EL-10 EL-11 EL-12 EL-13 EL-14 EL-15 EL-16 EL-17 EL-18
|
|
|