Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:R26-202-RNLG
 
 
Part:R26-202-RNLG
Description:Regulator Electronic 1/4"
Company:
Datasheet:Download R26-202-RNLG datasheet   File size : 40 kB
Request For quote:  Find where to buy R26-202-RNLG
 



Datasheet text preview:
Pneu-Stat
Electronic Pressure Regulator
q Fully programmable pressure regulation up to 8 bar q Can be used with any standard industrial PLC q Rapid acting - 8 bar step change in one second q Tough, accurate and reliable
Technical Data
Supply: Clean dry air (filtered to 5µ non-condensing, oil free). Up to 10 bar Output: 0-8 bar (user adjustable down to 0-4 bar). At zero control signal, 600l/min forward at 4 bar 300 l/min relief at 4 bar Operating Temperature Range: ­10 to +60°C. Response time into a 1 litre load
8 bar 8 bar
Ordering Information
The standard stock range is: 0-8 bar, 0-10V., G1/4. Customer calibration to other ranges and control signals is a simple adjustment. Alternative versions available ex-works are as follows:Range: Port: Control Signal: 0-10V 0-5V 4-20mA R26-200-RNLG R26-201-RNLG R26-202-RNLG R26-300-RNLG R26-301-RNLG R26-302-RNLG G1/4 0-8 bar G3/8
Accuracy
Out
< 2% error
¨
1 second
¨
0
100% Control Signal
9/94
8.6.132.01
Pneu-Stat Electronic Pressure Regulator Operation
The operational requirements are as indicated:-
Installation Construction
Enclosure: Case manufactured from zinc and reinforced plastic, finished with a black epoxy paint finish. Environmental protection rating IP65 The Pneu-Stat can be mounted in any orientation, a mounting bracket is provided. G1/4, G3/8 Front and rear facing Ports G1/4 30 mm square connector to DIN 43650. Orientable in four ways at 90°. Mating connector supplied. Span and zero - external Range select switches - internal 800g.
Mounting:
Pneumatic connections: Electrical connections:
Controls: Weight:
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under `Technical Data'. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
9/94
8.6.132.02