Small relay D2
V23042
PCB relay for DC voltage, polarized, monostable or bistable
F eatur es
q
Universally applicable in the most varied circuit functions in the field of telecommunications and small signal technology Versatile design as it can be delivered with different power consumptions (PN = 150 to 250 mW) as well as with reversed coil polarity High reliability due to slide-free operation of the middle spring High-voltage resistance according to FCC Part 68
Approx. 1.5 x original size
q
q
ECR0983-1
q
Typical applications
q
Versions
Relay types: monostable with 1 winding or bistable with 2 windings or bistable with 1 winding With 2 changeover contacts With double contacts For printed circuit assembling Immersion cleanable
Standard telecommunication relay for public and private networks and terminal equipment Interface relay for microcomputer systems Storage element for input and output equipment (bistable version) M easurement and control Autom obile technology Entertainment electronics Signalling systems M edical equipment
q q
q q q q q
Approvals
UL
File E 48393
CSA
File LR 50227-7
Siemens AG
3
Small relay D2
Dimension drawing (in mm)
Mounting hole layout
Vie w on the terminals
Monostable and bistable, 1 winding
Bistable, 2 windings
Ba sic grid 2.54 mm according to EN 60097 and DIN 40803 , fine
Basic grid 2.54 mm according to EN 60097 and DIN 40803, fine
Terminal assignment
Vie w on the terminals
Monostable and bistable, 1 winding
V2 30 42-A2III V2 30 42-C2III
Monostable and bistable, 1 winding
V230 42-A3III V230 42-C3III
Bistable, 2 windings
V23042-B2III
The switch position illustrated shows the release condition. If a positive potential is applied to terminal 1, the relay adopts the operating position.
Th e switch position illustrated shows the release condition. If a positive potential is applied to terminal 16, the relay adopts the operating position.
The switch position illustrated shows the release condition. If a positive potential is applied to terminal 1 or 15, the relay adopts the operating position.
4
Siemens AG
Small relay D2
Contact data
Ordering code block 3 Number of contact and type Contact assembly Contact material Max. continuous current at max. ambient temperature Maximum switching current Maximum switching voltage Maximum switching voltage according to VDE 0110, insulation group A Maximum switching capacity D C voltage AC voltage Recom mended for load voltages greater than Thermoelectric potential Contact resistance (initial value) / measuring current / driver voltage B101 2 changeover contacts Double contacts Gold-plated silver against palladium silver 2A 5A 250 V 220 V~ 150 V 125 V~ 50 ... 150 W, see load limit curve 250 VA 100 µV 10 µV 50 m / 10 mA / 20 mV Gold-plated palladium silver against palladium silver B201
Load limit curve
Curve II -B101/B201
Curve I -B101
Curve I -B201
I = switching current U = switching voltage = recommended application field
Definition of the load limit curve I: Definition of the load limit curve II: Quenching of the arc before the transit time In 1000 operations, no arc with a burning time of > 10 ms may occur
Siemens AG