Illuminated beacons and indicator banks
Characteristics
References : pages 5/39 and 5/40
Characteristics
Ambient air temperature Degree of protection Rated insulation voltage Consumption With steady or flashing circuit : operation : - 25...+ 70 °C With discharge circuit : storage : operation : - 10...+ 50 °C IP 42 conforming to IEC 529 Ui : 250 V With flashing circuit : (7 W bulb) - on c 24 V : 250 mA, - on c 230 V : 35 mA. With discharge circuit : (flashing lamp) - on a 24 V : 350 mA max. (switch-on : 720 mA), - on c 110/120 V : 100 mA, - on c 230 V : 80 mA. Audible elements : - a 12...48 V : 10...50 mA, - c 110...230 V : 3...7 mA. Illuminated units with steady or flashing circuit : BA 15d base fitting bulbs, minimum power 5 W, maximum power 7 W. Illuminated units with high intensity "flash" lamp (integral xenon tube) : 13.6 cds with clear lens. 90 db at 1 m, continuous or intermittent. Fundamental frequency : 3 kHz 1 terminal referenced "O" () common to all 5 possible stacked units, other terminals referenced 1 to 5, for use as required. Capacity : 2 x 2.5 mm2 max. Illuminated beacons and illuminated indicator banks are visual or audible signalling units used mainly to indicate machine operation sequences and to check status from a distance. They are visible through 360°. Example : start, stop machine, no material, call technical staff, fault indication, etc. i Illuminated beacon Pre-assembled with a single illuminating signalling unit : either steady, flashing or with high intensity xenon flash lamp : - optional accessory : anodised aluminium support tube ; 100 mm, 400 mm or 800 mm long, - optional accessory : support plate. i Illuminated indicator bank For assembly by the user, with up to 5 illuminated or 4 illuminated + 1 audible signalling units. It comprises : - a base, incorporating terminal block, cable clamp and support tube fixings, - 1 to 5 coloured lens units (green, red, orange, blue or clear) or 4 coloured lens units + 1 audible signalling units, - a top cover, where necessary, - optional accessory : anodised aluminium support tube ; 100 mm, 400 mm or 800 mm long, - optional accessory : support plate. The illuminated lens or audible signalling units stack vertically and are each locked by a single screw. Electrical connections between each unit are made automatically during assembly. i Fixing Base fitted directly onto panel by means of 2 screws. Fixed onto panel using support plate (4 fixing screws) and 100 mm, 400 mm or 800 mm anodised aluminium tube. i Cabling Internal connections are brought out to a terminal block, with protected screw and captive cable clamp terminals, incorporated in the base unit.
Bulb/lamp type
Audible signalling unit Terminal referencing Cabling
5
5/38
Te
Illuminated beacons and indicator banks
Complete units References
Characteristics : page 5/38
Illuminated beacons, direct or tube fixing
Description Complete assembly comprising : 1 cover 1 coloured lens unit 1 base unit X V A - L 3i Signal Steady light bulb not included (1) 230 V Colour Green Red Orange Blue Clear Flashing light bulb not included (1) c 24...230 V (± 10 %) Orange Blue Clear Discharge circuit for flashing light Integral high intensity xenon discharge tube X V A - L 4i a 24 V Blue Clear Discharge circuit for flashing light Integral high intensity xenon discharge tube c 110/120 V 50/60 Hz Green Red Orange Blue Clear Discharge circuit for flashing light Integral high intensity xenon discharge tube c 230 V (± 10 %) 50 Hz Green Red Orange Blue XVA-L66C024 XVA-L67C024 XVA-L63B120 XVA-L64B120 XVA-L65B120 XVA-L66B120 XVA-L67B120 XVA-L63A220 XVA-L64A220 XVA-L65A220 XVA-L66A220 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 0.210 Green Red Orange XVA-L45 XVA-L46 XVA-L47 XVA-L63C024 XVA-L64C024 XVA-L65C024 0.200 0.200 0.200 0.210 0.210 0.210 Green Red Reference XVA-L33 XVA-L34 XVA-L35 XVA-L36 XVA-L37 XVA-L43 XVA-L44 Weight kg 0.200 0.200 0.200 0.200 0.200 0.200 0.200
5
Clear XVA-L67A220 (1) Bulb type for use with direct supply : BA 15d base fitting incandescent, see page 5/41. Illuminated beacons without xenon flashing light XVA-L3i , XVA-L4i i Panel cut-out For direct fixing of illuminated beacons or indicator banks
with xenon flashing light XVA-L6i i i i i i
For tube fixing of illuminated beacons or indicator banks, using support plates
4xØ5 ou M5 (1)
(1) 2xØ4 ou M4
181
54
107
42
54
=
42 Ø68
=
=
42 Ø68
=
(1) Ø 25 max.
Te
5/39
Illuminated beacons and indicator banks
Adaptable sub-assemblies References
Characteristics : page 5/38
Illuminated indicator banks (up to 5 units), direct or tube fixing
Description Illuminated lens units Not interchangeable with illuminated beacons Signal Steady light bulb not included (1) 230 V Colour Green Red Orange Blue Clear Yellow Green Red Orange Blue Clear Green Red Orange Blue Clear Green Red Orange Blue Clear Green Red Orange Blue Clear Supply voltage Reference XVA-C33 XVA-C34 XVA-C35 XVA-C36 XVA-C37 XVA-C38 XVA-C43 XVA-C44 XVA-C45 XVA-C46 XVA-C47 XVA-C63C0241 XVA-C64C0241 XVA-C65C0241 XVA-C66C0241 XVA-C67C0241 XVA-C63B120 XVA-C64B120 XVA-C65B120 XVA-C66B120 XVA-C67B120 XVA-C63A220 XVA-C64A220 XVA-C65A220 XVA-C66A220 XVA-C67A220 Reference Weight kg 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.080 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 Weight kg
XVA-C34
XVA-C37
Flashing light bulb not included (1) c 24 to 230 V (± 10 %) High intensity xenon flashing light (Maximum of 1 unit per indicator bank, mounted at top) With discharge circuit Integral tube a 24 V (2) With discharge circuit Integral tube
XVA-C33
XVA-C35
c 110/120 V 50/60 Hz With discharge circuit Integral tube c 230 V (± 10 %) 50 Hz Signal
Description
+
XVA-C21
5
Illuminated indicator banks without xenon flashing light
Continuous a 12...48 V (2) XVA-C911 0.120 Intermittent a 12...48 V (2) XVA-C921 0.120 Continuous c 110...230 V XVA-C93 0.120 Intermittent c 110...230 V XVA-C94 0.120 Base unit + cover For bank without xenon flashing light XVA-C21 0.135 Base unit only For bank with xenon flashing light XVA-C07 0.120 Note : Illuminated indicator banks are supplied as sub-assemblies (for customer assembly). Each unit is packed individually and marked with its respective reference. Maximum number of units per bank : 5 illuminated units or 4 illuminated units + 1 audible unit (mounted at top). For accessories and spare parts see page 5/41. (1) Bulb type for use with direct supply : BA 15d base fitting incandescent, see page 5/41. (2) "" line to common terminal (PLC solid state PNP type output). For "+" line to common terminal (NPN), please consult your Regional customer centre. Audible signalling unit (90 db at 1 m) Illuminated indicator banks without xenon flashing light Number of illuminated or b audible signalling units (2) 1 107 2 159 3 211 4 263 5 315 (1) XVA-C21 (2) XVA-C3i , C4i or C9i i i Illuminated indicator banks with xenon flashing light (3) Number of illuminated or b audible signalling units (2) 0 181 1 233 2 285 3 337 4 389 (1) XVA-C07 (2) XVA-C3i , C4i or C9i i i ( 3 ) X V A - C 6i i i i i
with xenon flashing light
(3) (1) b
b
(2)
(2)
(1) = 42 Ø68 = =
(1) 42 Ø68 =
5/40