Part: EK09
Category: Others
Description: Evaluation Kit For To-3 And Mo-127 Packages
Company: Apex Microtechnology Corporation
Datasheet: Download EK09 datasheet File size : 74 kB
Request For quote: Find where to buy EK09
Datasheet text preview:
EVALUATION KIT FOR TO-3 AND MO-127 PACKAGES
EK09
MICROTECHNOLOGY
HTTP://WWW.APEXMICROTECH.COM
(800) 546-APEX
(800) 546-2739
INTRODUCTION
This kit provides a solid mechanical platform with good shielding and grounding to breadboard eight pin TO-3 packages or the MO127 package with 0.060" pins. This kit is not intended as an alternate for kits dedicated to specific amplifiers. See www.apexmicrotech.com for availability of dedicated kits. Construction will involve surface mounting and 3D techniques. Holes are provided to mount standard banana and BNC connectors for I/O. See the Apex Accessories Information data sheet for a selection of flat-back heatsinks and thermal washers for these packages. Note that HS11 is compatible with EK09 and all three sockets can be used if desired. If the EK09 is to be used as an MO-127 platform only, HS18 rated at 1° C/W is a cost effective alternative to HS11 if internal power dissipation permits. Lower cost alternatives for two package TO-3 applications are HS02 and HS14. For single package TO-3 applications the HS13 is also suitable. The six chip capacitors provided can be used as the critical first step in power supply bypass for dual supplies for all three sockets. These capacitors are rated at 200V.
ASSEMBLY
Let us define the side of the top board with solder pads for each pin (roughly triangular on the TO-3 sockets) as the component side, where all the support components will determine circuit function and will be inside the finished box. The other side of this board is hereby dubbed the amplifier side. Insert cage jacks from the amplifier side and solder. Consider one of these techniques: 1) Place cage jacks in holes, cover with one of the 6" copper sides, flip over and solder, or 2) place cage jacks on pins of the amplifier, insert and solder. If done carefully, technique 2 can be used for the MO-127 package with 0.040" leads. Starting with one short and one long side, locate a vertical square corner in your work area (a large heatsink standing on end works fine) and solder the two together. Repeat for the other two sides, and finally solder the two pairs together. With the component side up , place rectangle of sides on top and tack two opposite corners. When satisfied with alignment, solder the box together then add connectors and components as desired. Note that copper on the inside and on the top of the box will all be tied to ground. Copper on the four outer sides of the box will be floating unless you tie them down. Soldering a stranded #10 to #16 ground wire from the immediate area of the socket(s) to the ground connector of the power supply(ies) is good construction practice. If the circuit is not a bridge, run this same size wire from the socket area to the output return connector. This will avoid high currents in the ground plane which may destroy signal integrity or even an amplifier. This is a good time to think about star grounding where each ground connection has a dedicated path to the center of the star such that currents in any path are not capable of inducing voltage in any other path. Note that the layout makes it easy to locate the star center nearly coincident with the socket center. Auxiliary circuits may be mounted inside the box in 3-D fashion supported on ground connections or on daughter boards as convenient. Other style connectors, switches or indicators can easily be added by simply drilling the appropriate holes and mounting them.
PARTS LIST
Part # PB99-P2 PB99- P6 PB99-P7 MS02 MS04 OX7R105KWN Description Quantity top 1 side 2 side 2 cage jacks for one TO-3 socket 2 cage jacks for one MO-127 socket 1 1µF Cap 1825B105K201N,Novacap 6
BEFORE YOU GET STARTED
· Attempt to visualize the finished circuit mechanically and in terms of where the high currents flow. · Use proper ESD precautions. · Verify heatsink is adequate · Use thermal grease or Apex thermal washer. · Do not make or break any connection on a hot circuit. · Start with lowest rated voltages. · Checking for oscillations with an oscilloscope is a must.
APEX MICROTECHNOLOGY CORPORATION · TELEPHONE (520) 690-8600 · FAX (520) 888-3329 · ORDERS (520) 690-8601 · EMAIL prodlit@apexmicrotech.com
EK09
FIGURE 1. COMPONENTS INCLUDED IN EK09.
6"
EVALUATION KIT FOR TO-3 / MO-127 PACKAGES
1.75"
1.75"
1
1
5"
Component side
2 MS02,16 CAGE JACKS FOR TWO TO-3 SOCKETS MS04,12 CAGE JACKS FOR ONE MO-127 SOCKET OX7R105KWN, 6 CAPACITORS, 1µF, 200V
1 1
Amplifier side
APEX MICROTECHNOLOGY CORPORATION · 5980 NORTH SHANNON ROAD · TUCSON, ARIZONA 85741 · USA · APPLICATIONS HOTLINE: 1 (800) 546-2739
EVALUATION KIT FOR TO-3 / MO-127 PACKAGES
EK09
.
FIGURE 2. EXTERNAL WITH HEATSINK (HEATSINK, AMPLIFIER, CONNECTORS AND SWITCHES NOT SUPPLIED).
FIGURE 3. INSIDE OF ASSEMBLED BOX. HOLES FOR COMPONENTS ON LONG SIDE WERE USER DRILLED.
APEX MICROTECHNOLOGY CORPORATION · TELEPHONE (520) 690-8600 · FAX (520) 888-3329 · ORDERS (520) 690-8601 · EMAIL prodlit@apexmicrotech.com
EK09
EVALUATION KIT FOR TO-3 / MO-127 PACKAGES
FIGURE 4. SOCKET DETAIL SHOWS THE CENTER OF THE STAR GROUND SYSTEM IS RIGHT IN THE CENTER OF THE SOCKET.
This data sheet has been carefully CORPORATION · to be NORTH SHANNON ROAD assumed for possible inaccuracies or USA · APPLICATIONS HOTLINE: 1 (800) 546-2739 APEX MICROTECHNOLOGY checked and is believed 5980reliable, however, no responsibility·isTUCSON, ARIZONA 85741 · omissions. All specifications are subject to change without notice. EK09U REV. C FEBRUARY 2001 © 2001 Apex Microtechnology Corp.
Others parts begin by ek