Part: LBB127
Category: Discrete -> Solid State relays
Description: Dual Pole Optomos Relay
Company: Clare, Inc.
Datasheet: Download LBB127 datasheet File size : 87 kB
Request For quote: Find where to buy LBB127
Datasheet text preview:
LBB127
DUAL POLE OptoMOS® Relay
Load Voltage Load Current Max RON
LBB127 250 200 10
Units V mA
Description LBB127 is a 250V, 200mA, 10 2-Form-B relay. It features a superior combination of on-resistance and peak load current handling capability.
Features · Small 8 Pin DIP Package · Low Drive Power Requirements (TTL/CMOS Compatible) · No Moving Parts · High Reliability · Arc-Free With No Snubbing Circuits · 3750VRMS Input/Output Isolation · FCC Compatible · VDE Compatible · No EMI/RFI Generation · Machine Insertable, Wave Solderable · Surface Mount and Tape & Reel Versions Available
Approvals · UL Recognized: File Number E76270 · CSA Certified: File Number LR 43639-10 · BSI Certified to: · BS EN 60950:1992 (BS7002:1992) Certificate #: 7344 · BS EN 41003:1993 Certificate #: 7344
Applications · Telecommunications · Telecom Switching · Tip/Ring Circuits · Modem Switching (Laptop, Notebook, Pocket Size) · Hookswitch · Dial Pulsing · Ground Start · Ringer Injection · Instrumentation · Multiplexers · Data Acquisition · Electronic Switching · I/O Subsystems · Meters (Watt-Hour, Water, Gas) · Medical Equipment--Patient/Equipment Isolation · Security · Aerospace · Industrial Controls
Ordering Information Part # LBB127 LBB127P LBB127PTR LBB127S LBB127STR Description 8 Pin DIP (50/ Tube) 8 Pin Flatpack (50/ Tube) 8 Pin Flatpack (1000/ Reel) 8 Pin Surface Mount (50/ Tube) 8 Pin Surface Mount (1000/ Reel)
Pin Configuration
LBB127 Pinout
AC/DC Configuration + Control - Switch #1 Control - Switch #1 + Control - Switch #2 Control - Switch #2 1 2 3 4 8 7 6 5 Load - Switch #1 Load - Switch #1 Load - Switch #2 Load - Switch #2
Switching Characteristics of Normally Closed (Form B) Devices
10ms CONTROL
+90% +10% TOFF
+
90% TON
DS-LBB127-R3
www.clare.com
1
LBB127
Absolute Maximum Ratings (@ 25° C)
Parameter Input Power Dissipation Input Control Current Peak (10ms) Reverse Input Voltage Total Power Dissipation Isolation Voltage Input to Output Operational Temperature Storage Temperature Soldering Temperature DIP Package Flatpack/Surface Mount Package (10 Seconds Max.)
1 2
Min 3750 -40 -40 -
Typ Max Units - 1501 mW 50 mA 1 A 5 V - 8002 mW VRMS +85 °C +125 °C +260 +220 °C °C
Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability.
Derate Linearly 1.33 mw/°C Derate Linearly 6.67 mw/°C
Electrical Characteristics
Parameter Output Characteristics @ 25°C Load Voltage (Peak) Load Current* (Continuous) AC/DC Configuration Peak Load Current On-Resistance AC/DC Configuration Off-State Leakage Current Switching Speeds Turn-On Turn-Off Output Capacitance Input Characteristics @ 25°C Input Control Current Input Dropout Current Input Voltage Drop Reverse Input Voltage Reverse Input Current Common Characteristics @ 25°C Input to Output Capacitance Input to Output Isolation Conditions 10ms IL=200mA VL=250V IF=5mA,VL=10V IF=5mA,VL=10V 50V; f=1MHz IL=200mA IF=5mA VR=5V Symbol VL IL IL RON TON TOFF IF IF VF VR IR CI/O VI/O Min 5 0.4 0.9 3750 Typ 8 50 0.7 1.2 3 Max 250 200 400 10 1 5 5 50 1.4 5 10 Units V mA mA µA ms ms pF mA mA V V µA pF VRMS
*Note: If both poles operate simulataneously load current must be derated so as not to exceed the package power dissipation value.
2
www.clare.com
Rev. 3
LBB127
PERFORMANCE DATA*
35 30 Device Count (N) 25 20 15 10 5 0
LBB127 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25°C) IF = 5mADC
25 20 15 10
LBB127 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25°C) (Load Current = 200mADC; IF = 5mADC)
#
LBB127 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25°C) IF = 5mADC
Device Count (N)
Device Count (N) 5.325 5.495 5.665 5.835 6.005 6.175
# # ! !" !& ! !$ !!
5 0
1.17
1.19
1.21
1.23
1.25
LED Forward Voltage Drop (V)
On-Resistance ()
LBB127 Typical IF for Switch Operation (N=50 Ambient Temperature = 25°C) (Load Current = 200mADC)
25 20 15 10 5 0 1.4 1.8 2.2 2.6 3.0 3.4 LED Current (mA) 25 20 15 10 5 0
LBB127 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25°C) (Load Current = 200mADC)
25 20 15 10
LBB127 Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 200mADC; IF = 5mADC)
Device Count (N)
Device Count (N)
Device Count (N) 1.0 1.4 1.8 2.2 2.6 3.0
5 0 0.03 0.05 0.07 0.09 0.11 0.13
LED Current (mA)
Turn-On (ms)
25 20 15 10 5 0
LBB127 Typical Turn-Off Time (N=50 Ambient Temperature = 25°C) (Load Current = 200mADC; IF = 5mA)
250
Load Current (mA)
LBB127 Typical Load Current vs. Temperature
0.045 0.040 0.035 Leakage (µA) 0.030 0.025 0.020 0.015 0.010 0.005 0
LBB127 Typical Leakage vs. Temperature (Measured across Pins 5 & 6 or 7 & 8)
Device Count (N)
100 150 50 0 0 -40 -20 0 20 40 60 80 100 120
0.45
0.75
1.05
1.35
1.60
1.95
-40
-20
0
20
40
60
80
100
Turn-Off (ms)
Temperature (°C)
Temperature (°C)
3 400 350 200 250 100 150 50 0 0
LBB127 Typical Blocking Voltage vs. Temperature IF = 5mADC
LBB127 Typical Turn-On vs. Temperature (Load Current = 200mADC)
0.12 0.10 0.08 0.06 0.04 0.02 5mA 0 -40 -20 0 20 40 60 80 100 -40 Turn-Off (ms) Turn-On (ms) 2.500 2.000 1.500
LBB127 Typical Turn-Off vs. Temperature (Load Current = 200mA)
5mA
Blocking Voltage (VRMS)
10mA 1.000
20mA
0.500
-40
-20
0
20
40
60
80
100
0 Temperature (°C)
-20
0
20
40
60
80
100
Temperature (°C)
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department.
Rev. 3
www.clare.com
3
Others parts begin by lb
LB-1 LB-2 LB-3 LB-4 LB-5 LB-6
|
|
|