Details, datasheet, quote on part number:25CPV240
| |
| Part: | 25CPV240 |
| Category: | Discrete => Solid State relays |
| Description: | Phase Controlled0.04-25 Amps RMS180-280 Volts RMS0-5 Control - Volts DC |
| Company: | Crydom Corporation |
| Datasheet: | Download 25CPV240 datasheet File size : 35 kB |
| Request For quote: | Find where to buy 25CPV240
|
| |
Datasheet text preview:
Series CPV
Phase Control Modules
· 120 & 240 Vac Models · 0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary function modules provide control of the phased turn-on of a solid state relay, in response to the application of a 0-5 Vdc control signal. They must be used with Crydom Series 1 (-10) random turn-on solid state relays. Consult factory about use with 480 Vac loads. For a complete set (control module and solid state relay) order 10CPV120, 25CPV120, etc. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.
MODEL NUMBERS
120 Vac 240 Vac
10CPV120 10CPV240
25CPV120 25CPV240
40CPV120 50CPV240 75CPV240 90CPV240
R E L A Y OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range [Arms] Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case [RJC] ¡C/W Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time [msec] Max. Turn-Off Time Power Factor (Min.) with Max. Load
90-140 (120 Vac Models) 180-280 (240 Vac Models) .04-10 .04-25 .04-50 .04-75 .04-90
400 (120 Vac models) 600 (240 Vac models) 120 1.6 1.48 60 10.0 500 0.02
1/ 2
250 1.6 1.02 260 10.0 500 0.02
1/ 2
625 1.6 0.63 1620 10.0 500 0.02
1/ 2
1000 1.6 0.31 4150 10.0 500 0.02
1/ 2
1200 1.6 0.28 6000 10.0 500 0.02
1/ 2
cycle 0.5
cycle 0.5
cycle 0.5
cycle 0.5
cycle 0.5
C O N T R O L M O D U L E INPUT SPECIFICATIONS
Logic Supply Range (Terminal 3A) Typical Supply Current Control Voltage Range (Terminal 3B) Nominal Control Input Impedance Min. Turn-Off Voltage
D C CONTROL
3.5-10Vdc 1.6mA @ 5Vdc 0-5 Vdc 1500 Ohms 1.0
C O N T R O L M O D U L E OUTPUT (Terminal 4B Ð I n p u t t o Relay)
Max. Off-State Operating Voltage Max. Load Current (Sink) Max. On-State Voltage @ 3mA Max. Off-State Leakage @ 10Vdc
36 Vdc 3.0 mA 0.5 Vdc 1.0 µAdc
© 2001 CRYDOM CORP, Specifications subject to change without notice.
G E N E R A L NOTES
All parameters at 25¼C unless otherwise specified. Off-State dv/dt test method per
EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required (Relay Only),
see Series 1 data sheet. FastFax Document No. 203 SERIES CPV Rev. 012402 PAGE 1 OF 2
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
Series CPV
Phase Control Modules
G E N E R A L SPECIFICATIONS
Dielectric Strength, Signal to Load Dielectric Strength, Signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range
M E C H A N I C A L SPECIFICATIONS Weight: (typical)
4000 Vrms 4000 Vrms -30 to 80¼C -40 to 125¼C 3.0 oz. (43g) Thermally Conductive Epoxy
Encapsulation:
A V A I L A B L E OPTIONS CPV120 Control Module Only (120 Vac line) CPV2 4 0 Control Module Only (120 Vac line)
MOUNTING HOLE/SLOT 0.17 (4.3) DIA.
1.10 (27.9) .50 (12.7)
.270 (2) (6.9)
FASTON TERMINAL .250 X .032 4 PLCS.
DERATING CURVES Ð See Series 1
1.87 (47.5) 2.30 (58.4) 1.70 (43.2)
1A 1B Positive Supply (+) (5Vdc) Control Voltage (+) (0 to 5Vdc) Common (Ð) Line
2B 2A
.270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2)
4A 4B
--
CONTROL MODULE
3B 3A
+
1.00 (25.4) 1.80 (45.7)
All dimensions are in inches (millimeters)
Load
OUTPUT
1
Ð10 RELAY
2
4
INPUT
3
Notes
1. Following pins may be interchanged: 1A & 1B, 2A & 2B. 2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B. 3. The line and load may be interchanged.
© 2001 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 203 SERIES CPV Rev. 012402 PAGE 2 OF 2
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
|
|