Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:NTD2405
 
 
Part:NTD2405
Category:Discrete => Solid State relays
Description:Zero Cross0.15-5 Amps RMS24-280 Volts RMS4-15 Control - Volts DC
Company:Crydom Corporation
Datasheet:Download NTD2405 datasheet   File size : 57 kB
Request For quote:  Find where to buy NTD2405
 



Datasheet text preview:
Series NTD/NTA
10-25Amp · 120/240 Vac · AC OUTPUT · Panel Mount · Zero Voltage or Random Turn-On Switching · Wide Control Voltage Range · DC Control, AC Control
The Series NTD is available featuring zero-voltage or random switching and a broadened operating range (24280Vac). This wide range permits optimum performance at both 120Vac and 240Vac line voltages. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability.
DC Control (NTD)
AC Control (NTA) NTA2410 24-280 0.15-10 600 120 1.6 1.48 60 10 200 10 ms 40 ms 0.5 NTA2425 24-280 0.15-25 600 250 1.6 1.02 260 10 200 10 ms 40 ms 0.5
O U T P U T SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] Load Current Range
NTD2405 24-280 0.15-5 600 40 1.6 4.5 7.0 .01 200 1/2 Cycle 1/2 Cycle 0.5
NTD2410 24-280 0.15-10 600 120 1.6 1.48 60 10 200 1/2 Cycle 1/2 Cycle 0.5
NTD2425 24-280 0.15-25 600 250 1.6 1.02 260 10 200 1/2 Cycle 1/2 Cycle 0.5
[Arms]
Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (R JC [°C/W] ) Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mA] Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] Max. Turn-On Time Max. Turn-Off Time Power Factor (Min.) with Max. Load
I N P U T SPECIFICATIONS
Control Voltage Range Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current @ 5 Vdc (@ 120 Vrms for NTA)
4-15 Vdc 4.0 Vdc 1.0 Vdc 300 ohms 13 mAdc
3-32 Vdc 3.0 Vdc 1.0 Vdc See note | 10 mAdc
3-32 Vdc 3.0 Vdc 1.0 Vdc See note | 10 mAdc
90-140 Vrms 90-140 Vrms 90 Vrms 10 Vrms 10.6 kOhm 10 mArms 90 Vrms 10 Vrms 10.6 kOhm 10 mArms
GENERAL NOTES
© 2002 CRYDOM CORP, Specifications subject to change without notice.
|
All parameters at 25°C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 2. Turn-On time for random turn-on versions is 0.02 msec. (DC control models) Input circuitry incorporates active current limiter. 24 Vac Control Version Available (use suffix E)
FastFax Document No. 176 SERIES NTD/NTA Rev. 041702 PAGE 1 OF 2
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
Series NTD/NTA
10-25Amp · 120/240 Vac · AC OUTPUT
G E N E R A L SPECIFICATIONS Dielectric Strength 50/60Hz, Input/Output/Base Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range M E C H A N I C A L SPECIFICATIONS Weight: (typical) Encapsulation: Terminals: 3750 Vrms 109 Ohm 10 pF -40 to 80°C -40 to 125°C
3.0 oz. (86.5g) Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING HOLE/SLOT 0.17 (4.3) DIA.
1.10 (27.9) .45 (11.4)
8-32 TERMINAL (2 PLACES )
MOUNTING HOLE/SLOT 0.17 (4.3) DIA.
1.10 (27.9) .45 (11.4)
FASTON TERMINAL .250 X .032 (4 PLCS.) .87 REF. (22.2)
All dimensions are in inches (millimeters)
1
1.87 (47.5)
OUTPUT
2
SOLID-STATE RELAY
-4
INPUT
+
3
2.30 (58.4) 1.70 (43.2)
1
1.87 (47.5)
OUTPUT
2
2.30 (58.4) 1.70 (43.2)
SOLID-STATE RELAY
-4
INPUT
+
3
Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) Terminal Hardware Furnished: 4 Screws and 4 Saddle Clamps
BASE PLATE .125 (3.2)
1.00 (25.4) 1.80 (45.7)
6-32 TERMINAL (2 PLACES)
.78 (19.8) .90 (22.9)
1.00 (25.4) 1.80 (45.7)
.78 (19.8) 1.25 (31.8)
Crydom Heat Sinks offer excellent thermal management and are per fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details.
AVAILABLE OPTIONS -10 Random Turn-On Phase Controllable Example: NTD2425-10 F Faston Terminals .250 x .032 Faston Terminals (Shown above) Example: NTD2425F 24 Vac Control Example: NTA2425E
E
C U R R E N T DERATING CURVES
5A
6
Base Plate Temp [°C]
10A
12
10°C/W 7°C/W 5°C/W NO HEATSINK 3°C/W
25A
30
1°C/W
95
Base Plate Temp [°C]
9°C/W
5°C/W
Base Plate Temp [°C]
5
Power Dissipation
110
110
25
Power Dissipation
3°C/W 2°C/W
100
Power Dissipation
4 3 2 120 1 115
8
NO HEATSINK
20 15 10
NO HEATSINK
115
110
4
120
5 0 1 2 3 4 5 10 20 40 60 80 2 4 6 8 10 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C] Load Current [Arms] Max Ambient Temp. [°C]
120 5 10 15 20 25 20 40 60 80
0
Load Current [Arms] Max Ambient Temp. [°C]
APPROVALS UL E116950 CSA PENDING TUV PENDING
FastFax Document No. 176 SERIES NTD/NTA Rev. 041702 PAGE 2 OF 2
© 2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 · FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506