Details, datasheet, quote on part number:UWR-12/250Series
| |
Datasheet text preview:
®
®
w w w .d a te l.c o m
INNOVATION and EXCELLENCE
Single Output
UWR Models
Low-Cost, DIP-Packaged 3 Watt, DC/DC Converters
Features
s
Low cost! Automated, SMT-on-pcb construction Industry-standard package and pinout 1.25" x 0.8" x 0.45" DIP form factor No external components required 5, 12 or 15 Volt outputs Choice of 3 ultra-wide input ranges: 4.5 - 9 Volts 9 - 18 Volts 18 - 72 Volts Guaranteed efficiencies to 76% Fully isolated, 1000Vdc guaranteed 25 to +75°C operation with no derating UL 1950, CSA 22.2 No. 234 and IEC 950 EMI/EMC characterized Modifications and customs for OEM's
n n n n n n
n n n n n n
The 3 Watt, single-output, UWR Models of DATEL's XWR Series DC/DC converters deliver impressive levels of cost-effectiveness in an industry-standard package and pinout. These highly-efficient (as high as 76% guaranteed), fully isolated (1000Vdc minimum), DIP-packaged power converters provide true component-like convenience and flexibility to designers of modern distributed power systems. Exploiting high-frequency (170-200kHz), flyback topologies and contemporary, highly automated, SMT assembly techniques, UWR Model DC/DC's have enough space to include input (pi type) and output filters within their package. Requiring no external components, these converters offer true "plug-and-play" convenience. They operate over the full 25 to +75°C temperature range with no output power derating. Output voltages are either 5, 12 or 15 Volts. Input voltage ranges are either 4.5-9V ("D5" models), 9-18V ("D12" models) or an ultra-wide 18-72V ("D48" models). Transient response time is a quick 200µsec. These extremely rugged modules are fully encapsulated with a thermally conductive potting compound. They are moisture and vibration resistant and have established a reputation for outstanding MTBF. For telecommunication, computer and other EMIsensitive applications, these DIP-packaged DC/DC converters offer full EMI/EMC characterization data. DATEL's UWR Model 3W DC/DC's are ideal replacements for other more costly, less reliable power converters as well as excellent choices for new design-ins in systems demanding small size, low cost and high reliability.
+VIN
+VOUT
COMMON
VIN
PWM CONTROLLER
OPTO ISOLATION
REFERENCE & ERROR AMP
Figure 1. Simplified Schematic
DATEL, Inc., 11 Cabot Boulevard, Mansfield, MA 02048 (U.S.A.) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: datellit@mcimail.com
XWR Series
3W,
SINGLE
OUTPUT
DC/DC
CONVERTERS
Performance Specifications and Ordering Guide
Output Model
UWR-5/500-D5 UWR-5/500-D12 UWR-5/500-D48 UWR-12/250-D5 UWR-12/250-D12 UWR-12/250-D48 UWR-15/200-D5 UWR-15/200-D12 UWR-15/200-D48
Input Regulation (Max.) Line Load
±0.2% ±0.2% ±0.2% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
VOUT (Volts)
5 5 5 12 12 12 15 15 15
IOUT (mA, Max.)
500 500 500 250 250 250 200 200 200
R/N (mVp-p) Typ. Max.
75 75 75 75 75 75 75 75 75 120 120 120 150 150 150 150 150 150
VIN Nom. (Volts)
5 12 48 5 12 48 5 12 48
Range (Volts)
4.5-9 9-18 18-72 4.5-9 9-18 18-72 4.5-9 9-18 18-72
IIN (mA)
18/694 25/282 6/65 30/800 25/340 11/78 30/811 25/340 11/78
Efficiency Min. Typ.
70% 70% 75% 72% 72% 76% 72% 72% 76% 72% 72% 77% 75% 74% 80% 74% 76% 78%
Package (Case, Pinout)
C1, P1 C1, P1 C1, P1 C1, P1 C1, P1 C1, P1 C1, P1 C1, P1 C1, P1
Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted. Ripple/Noise (R/N) measured over a 20MHz bandwidth. 10% to 100% load. Nominal line voltage, no-load/full-load conditions.
PART NUMBER STRUCTURE
MechC nicaNSpecifications I F I C A T I O N S M E aH A l I C A L S P E C
U W R - 5 / 500 - D 4 8
Output Configuration: U = Unipolar Wide Range Input Nominal Output Voltage: 5, 12 or 15 Volts Input Voltage Range: D5 = 4.5-9 Volts (5V nominal) D12 = 9-18 Volts (12V nominal) D48 = 18-72 Volts (48V nominal) Maximum Output Current in mA
0.100 (2.54) 0.45 (11.43) 1.25 (31.75) STANDOFFS 0.025 (0.64)
Case C1
0.020 ±0.002 DIA. (0.508 ±0.051) 0.600 (15.24) 0.200 (5.08) 0.18 (4.57) 0.15 MIN (3.81)
34
7
8 0.600 (15.24) 0.80 (20.32)
12
5
6
BOTTOM VIEW PLASTIC CASE WITH AN INSULATED BASE 0.10 (2.54)
I/O Connectiions Pin 1 2 3 4 5 6 7 8 Function P1 +Input +Input Input Input Common +Output Common +Output
2
3W,
SINGLE
OUTPUT
DC/DC
CONVERTERS
UWR Models
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range: "D5" Models "D12" Models "D48" Models Input Current Input Filter Type Reverse-Polarity Protection VOUT Accuracy (50% load) Temperature Coefficient Ripple/Noise (20MHz BW) Line/Load Regulation Efficiency Isolation Voltage Current Limiting: "D5" Models "D12" and "D48" Models Transient Response (50% load step) Switching Frequency: "D5" Models "D12" and "D48" Models Operating Temperature (Ambient, no derating) Storage Temperature Dimensions Case Material Pin Material Weight 4.5-9 Volts (5V nominal) 9-18 Volts (12V nominal) 18-72 Volts (48V nominal) See Ordering Guide Pi Yes (Instantaneous, 2A maximum) Input Voltage: "D5" Models "D12" Models "D48" Models
A b s o l u t e Maximum Ratings
12 Volts 20 Volts 80 Volts Current must be <2A. Brief duration only. Fusing recommended. None Current limited. Max. current and short-circuit duration are model dependent. "D12" and "D48" models can withstand sustained output short circuits. 40 to +100°C + 3 0 0° C
Input Reverse-Polarity Protection Output Overvoltage Protection Output Current
Output
±1%, maximum ±0.02% per °C See Ordering Guide See Ordering Guide See Ordering Guide 1000Vdc, minimum Power-limiting technique, auto-recovery Hiccup technique, auto-recovery
Storage Temperature Lead Temperature (soldering, 10 sec.)
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied.
Dynamic Characteristics
200µsec to ±1% of final value
TECHNICAL NOTES
Floating Outputs
200kHz 170kHz
Environmental
25 to +75°C 40 to +100°C
Since these are isolated DC/DC converters, their outputs are "floating." Users may ground either the Common (pins 5 and 7) for normal usage or the positive side (+Output, pins 6 and 8) to effectively reverse the output polarity. Filtering and Noise Reduction All UWR 3 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by installing electrolytic capacitors across the input terminals and/or low-ESR tantalum or electrolytic capacitors across the output terminals. The caps should be located as close to the power converters as possible. Typical values are listed in the tables below. In many applications, using values greater than those listed will yield better results. To Reduce Input Ripple "D5" Models "D12" Models "D48" Models To Reduce Output Ripple 5V Output 12/15V Outputs 47µF, 15V 10µF, 35V 4.7µF, 100V 47µF, 10V, Low ESR 22µF, 20V, Low ESR
Physical
1.25" x 0.8" x 0.45" (31.8 x 20.3 x 11.4mm) Diallyl phthalate, UL94V-0-rated Brass, solder coated 0.5 ounces (14.2 grams)
These power converters require a minimum 10% loading to maintain specified regulation. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. Application-specific internal input/output filtering can be recommended and perhaps added internally upon request. Contact DATEL Applications Engineering for details. Devices can be screened or modified for higher guaranteed isolation voltages. Contact DATEL Applications Engineering for details. Devices can be warranted or screened for lower-temperature operation. Contact DATEL Applications Engineering for details. See DATEL's new UST 3W Models for guaranteed operation to 40°C.
In critical, space-sensitive applications, DATEL may be able to tailor the internal input/output filtering of these units to meet your specific requirements. Contact our Applications Engineering Group for additional details.