Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:UWR-12/420-D24
 
 
Part:UWR-12/420-D24
Category:Power Management => DC-DC Converters
Description:12V Miniature, 5W, DC/DC Converter
Company:Datel, Inc.
Datasheet:Download UWR-12/420-D24 datasheet   File size : 93 kB
Request For quote:  Find where to buy UWR-12/420-D24
 



Datasheet text preview:
®
®
INNOVATION and EXCELLENCE
Single Output
UWR Models
Miniature, 1" x 1" 5 Watt, DC/DC Converters
Features
s s s s
Small size, 1" x 1" x 0.45" Full 5 Watts output power No external components required Drop-in replacements for many standard, 2" x 1" DC/DC's Wide input voltage ranges: 18-36V or 36-72V 5, 12, or 15V outputs Guaranteed efficiencies to 80% Fully regulated and isolated (1000Vdc guaranteed) Output overvoltage protection and current limiting ­25 to +95oC operating temperature Shielded cases (5 sides) UL 1950, CSA 22.2 No. 234, IEC 950 Modifications and customs for OEM's
s
s s s
s
s s s s
The migration to distributed power is accelerating. The critical need for accurate voltages, tight regulation and rapid transient response is propelling the move to power processing at the "point-of-use" with low-power DC/DC converters physically located right at their loads. DATEL's miniature, full featured, 5 Watt UWR Models were specifically designed for today's demanding distributed power architectures in aerospace, marine, telecom and computer applications. The converters' low cost, small size (1" x 1" x 0.45") and full 5 Watt output capability give system architects unprecedented design and layout flexibility. Occupying less than 0.5in3 total volume, these extremely compact, fully regulated and isolated (1000Vdc guaranteed) modules are available with either 5, 12 or 15 Volt outputs. Input voltage ranges are either 18-36 Volts ("D24" models) or 36-72 Volts ("D48" models). Although their overall size is 50-75% smaller than many similarly rated power modules, these 1" x 1" UWR Models are exact, drop-in, pin-for-pin replacements for many standard 2" x 1" and 2" x 2", 5 Watt modules. They achieve their small size and low cost by exploiting a novel feedback approach that does not depend upon traditional optocoupler techniques. All models are 5-side shielded and have a non-conductive baseplate that permits pccard runs to be placed beneath the package. Units are assembled using high-speed automated SMT techniques and are fully encapsulated with thermally conductive potting compound. Every unit is electrically tested before and after encapsulation, 100% burnedin under full load, hi-pot tested, and final-electrical tested prior to shipment. Every unit meets DATEL's traditional high standards for quality and long-term reliability.
+VIN
*
PWM +VOUT
COMMON
­VIN
* "D24" models only Figure 1. Simplified Schematic
DATEL, Inc., Mansfield, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: sales@datel.com · Internet: www.datel.com
XW R Series
M I N I AT U R E ,
5 WAT T
DC/DC
CONVERTERS
Performance Specifications and Ordering Guide
Output Model
UWR-5/1000-D24 UWR-5/1000-D48 UWR-12/420-D24 UWR-12/420-D48 UWR-15/335-D24 UWR-15/335-D48
Input Regulation (Max.) Load Line
±2% ±2% ±2% ±2% ±2% ±2% ±2% ±2% ±2% ±2% ±2% ±2%
VOUT (Volts)
5 5 12 12 15 15
IOUT (mA, Max.)
1000 1000 420 420 335 335
Ripple/Noise (mVp-p, Max.)
120 120 150 150 150 150
VIN Nom. (Volts)
24 48 24 48 24 48
Range (Volts)
18-36 36-72 18-36 36-72 18-36 36-72
IIN (mA, Max.)
25/282 25/141 25/265 25/133 25/264 25/132
Efficiency (Min.)
75% 75% 80% 80% 80% 80%
Package (Case, Pinout)
C7, P3 C7, P3 C7, P3 C7, P3 C7, P3 C7, P3
Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted. Ripple/Noise (R/N) measured over a 20MHz bandwidth. 20% to 100% load. Nominal line voltage, no-load/full-load conditions.
PART NUMBER STRUCTURE
M E C H A N I C A L S P E C I F I C AT I O N S
U W R - 1 5 / 335 - D 2 4
Output Configuration: U = Unipolar Input Voltage Range: D24 = 18-36 Volts (24V nominal) D48 = 36-72 Volts (48V nominal) Maximum Output Current in mA
0.45 (11.43) 1.00 (25.40) METAL CASE
Wide Range Input
Case C7
INSULATED BASE
Nominal Output Voltage 5, 12 or 15 Volts
0.20 MIN. (5.08)
0.040 ±0.002 DIA. (1.016 ±0.051) 0.800 (20.32) 0.10 (2.54)
0.100 (2.54) 1
3 0.400 (10.16) 4 2 5 1.00 0.800 (20.32) (25.40)
T E M P E R AT U R E D E R AT I N G
5 4.5 4
0.200 (5.08)
6 BOTTOM VIEW 0.200 (5.08) 0.10 (2.54)
Output Power (Watts)
3.5 3 2.5 2 1.5 1 0.5 0 ­25 0 35 40 45 50 55 60 65 70 75 80 85 90 95
I/O Connections Pin 1 2 3 4 5 6 Function P3 +Input ­Input +Output No Pin No Pin Common
Notes:
For "D24" models, the case is connected to pin 2 (­VIN). For "D48" models, the case is connected to pin 1 (+VIN).
Ambient Temperature (°C)
2
M I N I AT U R E ,
5 WAT T
DC/DC
CONVERTERS
UWR Models
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range: "D24" Models "D48" Models Input Current Input Filter Type Reverse-Polarity Protection VOUT Accuracy (50% load): 5V Outputs 12/15V Outputs Temperature Coefficient Ripple/Noise (20MHz BW) Line Regulation Load Regulation Efficiency Isolation Voltage Current Limiting Overvoltage Protection Transient Response (50% load step) Switching Frequency Operating Temperature (Ambient): Without Derating With Derating Storage Temperature Dimensions Shielding Case Connection: "D24" Models "D48" Models Case Material 18-36 Volts (24V nominal) 36-72 Volts (48V nominal) See Ordering Guide LC on "D24" models C on "D48" models Yes (Instantaneous, 6A maximum)
A b s o l u t e Maximum Ratings Input Voltage: "D24" Models "D48" Models Input Reverse-Polarity Protection Output Overvoltage Protection: 5V Outputs 12V Outputs 15V Outputs Output Current 40 Volts 80 Volts Current must be < 6A. Brief duration only. Fusing recommended. 6.8 Volts, limited duration 15 Volts, limited duration 18 Volts, limited duration Current limited. Max. current and short-circuit duration are model dependent. ­55 to +125°C +300°C
Output
±1.5%, maximum ±1%, maximum ±0.02% per °C See Ordering Guide See Ordering Guide See Ordering Guide See Ordering Guide 1000Vdc, minimum Auto-recovery
Storage Temperature Lead Temperature (soldering, 10 sec.)
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Perfor mance/Functional Specifications Table is not implied.
TECHNICAL NOTES
Zener/transorb clamp
Dynamic Characteristics
500µsec max. to ±2% of final value 170kHz (±10kHz)
Floating Outputs Since these are isolated DC/DC converters, their outputs are "floating." Users may ground either the Common (pin 6) for normal usage or the positive side (+Output, pin 3) to effectively reverse the output polarity. Filtering and Noise Reduction All UWR 5 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by installing low-ESR, tantalum or electrolytic capacitors across the input and/or output terminals. The capacitors should be located as close to the power converters as possible. Typical values are listed below. In many applications, using values greater than those listed will yield better results. To Reduce Input Ripple "D24" Models "D48" Models To Reduce Output Ripple 5V Outputs 12/15V Outputs 20µF, 50V 10µF, 100V 47µF, 10V, Low ESR 33µF, 20V, Low ESR
Environmental
­25 to +60°C to +95°C (See Derating Curve) ­55 to +125°C
Physical
1" x 1" x 0.45" (25.4 x 25.4 x 11.4mm) 5-sided Pin 2 (­VIN) Pin 1 (+VIN) Corrosion resistant steel with non-conductive,epoxy-based, black enamel finish and plastic baseplate Brass, solder coated
Pin Material
These power converters require a minimum 20% loading to maintain specified regulation. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. Application-specific input/output filtering can be recommended and perhaps added internally upon request. Contact DATEL Applications Engineering for details. Units can be screened or modified for higher guaranteed isolation voltages. Contact DATEL Applications Engineering for details. Units can be warranted or screened for lower-temperature operation. Contact DATEL Applications Engineering for details.
In critical, space-sensitive applications, DATEL may be able to tailor the internal input/output filtering of these units to meet your specific requirements. Contact our Applications Engineering Group for additional details. Input Fusing Cer tain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. For DATEL UWR 5 Watt DC/DC Converters, you should use slow-blow type fuses with values no greater than 0.5A.
3