Details, datasheet, quote on part number:UWR-12/750-D48A
 
 
Part:UWR-12/750-D48A
Category:Power Management => DC-DC Converters
Description:12V 6-10W, Single Output DC/DC Converter
Company:Datel, Inc.
Datasheet:Download UWR-12/750-D48A datasheet   File size : 132 kB
Request For quote:  Find where to buy UWR-12/750-D48A
 



Datasheet text preview:
®
®
INNOVATION and EXCELLENCE
Single Output
A-Series, UWR Models
A-SERIES
High-Reliability, 2" x 1" 6-10 Watt, DC/DC Converters
Features
Low Cost! Highly reliable! Proven SMT-on-pcb construction Designed to meet UL1950 and EN60950 Qual tested; HALT tested; EMC tested Small packages, 2" x 1" x 0.375" Standard pinouts 5, 5.2, 12 or 15 Volt outputs Choice of 3 wide-range inputs: 4.7-7.25 Volts 9-18 Volts 18-75 Volts Fully isolated, 1500Vdc guaranteed ­40 to +100°C operation 5-side metal shielded cases with non-conductive baseplates Modifications and customs for OEM's
Placing reliability and cost considerations above all others, DATEL's new A-Series DC/DC Converters combine straightforward circuit topologies, the newest components, proven SMT-on-pcb construction, and highly repeatable automatic assembly techniques. Considering the critical low-cost and long-termreliability requirements of today's telecom, datacom and computer/networking applications, the A-Series may well be the most cost-effective DC/DC's available today. The single-output, 6-10 Watt Models of the A-Series deliver both high power densities and impressive MTBF's. Their superior durability is substantiated by a rigorous in-house qualification program including HALT (Highly Accelerated Life Testing). The goal of HALT is not to simulate field conditions but to expose devices to multiple excessive stresses with the intention of precipitating any potential electrical, mechanical or process weaknesses. Packaged in 2" x 1" x 0.375" shielded metal cases with non-conductive coatings, these fully isolated (1500Vdc guaranteed) DC/DC's offer excellent line/load regulation, full I/O protection, thermal shutdown, and industry-standard pinouts. Output voltages include 5, 5.2, 12 and 15 Volts. Input voltage ranges are either 4.7-7.25V ("D5A" models), 9-18V ("D12A" models) or 18-75V ("D48A" models). All A-Series UWR models are fully EMI characterized and UL1950, CSA950 and IEC950 safety approved. A-Series DC/DC's are extremely reliable, easy-to-use, cost-effective power conver ters. Use them to improve the reliability of existing equipment or to develop new systems that exceed design objectives.
+VIN (1)
+VOUT (3)
COMMON (5)
­VIN (2)
PWM CONTROLLER
OPTO ISOLATION
REFERENCE & ERROR AMP
Figure 1. Simplified Schematic
DATEL, Inc., Mansfield, MA 02048 (USA) · Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 · Email: sales@datel.com · Internet: www.datel.com
A Series
6 - 1 0 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S
Performance Specifications and Ordering Guide
Output Model
UWR-5/1600-D5A UWR-5/1800-D48A UWR-5/2000-D12A UWR-5/2000-D24E UWR-5/2000-D48E UWR-5.2/1500-D5A UWR-12/665-D5A UWR-12/750-D48A UWR-12/830-D12A UWR-15/530-D5A UWR-15/600-D48A UWR-15/665-D12A
Input Max.
100 100 75 75 75 100 100 100 100 100 100 100
VOUT * (Volts)
5 5 5 5 5 5.2 12 12 12 15 15 15
IOUT (mA)
1600 1800 2000 2000 2000 1500 665 750 830 530 600 665
R/N (mVp-p) Typ.
50 75 50 50 50 50 75 75 75 50 75 75
Regulation (Max.) Line Load
±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
VIN Nom. (Volts)
5 48 12 24 48 5 5 48 12 5 48 12
Range (Volts)
4.7-7.25 18-75 9-18 18-36 36-72 4.7-7.25 4.7-7.25 18-75 9-18 4.7-7.25 18-75 9-18
IIN (mA)
20/2105 10/240 15/1029 10/490 10/248 20/2053 25/2046 10/230 35/988 40/2065 10/233 35/978
Efficiency Min. Typ.
74% 78% 79.5% 83% 82% 74% 75% 81.5% 81% 75% 81.5% 82% 76% 81% 81% 85% 84% 76% 78% 82.5% 84% 77% 84% 85%
Package (Case, Pinout)
C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11 C2, P11
Typical at TA = +25°C under nominal line voltage and full-load conditions unless otherwise noted. Ripple/Noise (R/N) measured over a 20MHz bandwidth. 10% to 100% load. Nominal line voltage, no-load/full-load conditions. See Technical Notes for an explanation of trading off input voltage ranges for higher full-power operating temperature.
* Contact DATEL for availablility of 3.3V outputs.
PA R T N U M B E R S T R U C T U R E
M E C H A N I C A L S P E C I F I C AT I O N S
U WR - 5 / 1800 - D48 A
Output Configuration: U = Unipolar Wide Range Input Nominal Output Voltage: 5, 5.2, 12 or 15 Volts A-Series High Reliability Input Voltage Range: D5 = 4.7-7.25 Volts (5V nominal) D12 = 9-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 18-75/36-72 Volts (48V nominal) Maximum Output Current in mA
1
1.00 (25.40) 0.375 (9.53)
2.00 (50.80) METAL CASE
Case C2
INSULATED BASE 0.20 MIN (5.08) 0.800 (20.32)
0.040 ±0.002 DIA. (1.016 ±0.051) 0.60 (15.24)
3 4
0.100 (2.54)
0.800 (20.32) 0.400 (10.16)
2 5 0.200 (5.08) BOTTOM VIEW 0.10 (2.54)
T E M P E R AT U R E D E R AT I N G
10 9 8 A, C D, E B C A
DIMENSIONS ARE IN INCHES (MM)
D
Output Power (Watts)
7 6
E
I/O Connections
5 4 3 2 1 0 ­40 0 40 45 50 55 60 65 70 75 80 85 90 95 100 UWR-5/1600-D5A UWR-5/1800-D48A UWR-5/2000-D12A UWR-5/2000-D24E UWR-5/2000-D48E UWR-5.2/1500-D5A UWR-12/665-D5A UWR-12/750-D48A UWR-12/830-D12A UWR-15/530-D5A UWR-15/600-D48A UWR-15/665-D12A B D C A A B B E C B E C
Pin 1 2 3 4 5
Function P11 +Input ­Input +Output No Pin Common
Notes:
For "D5A, D12A and D24E" models, the case is connected to pin 2 (­VIN). For "D48A and D48E" models, the case is connected to pin 1 (+VIN).
Ambient Temperature (°C)
2
6 - 1 0 W, S I N G L E O U T P U T D C / D C C O N V E RT E R S
UWR Models
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and full-load conditions, unless noted.
Input
Input Voltage Range: D5A Models D12A Models D24E Models D48A Models D48E Models Input Current Input Filter Type Overvoltage Shutdown: D5A Models D12A Models D24E Models D48A and D48E Models Reverse-Polarity Protection VOUT Accuracy (50% load) Temperature Coefficient Ripple/Noise (20MHz BW) Line/Load Regulation Efficiency Isolation Voltage Isolation Capacitance Current Limiting Overvoltage Protection Transient Response (50% load step) Switching Frequency Operating Temperature (Ambient): Without Derating With Derating Storage Temperature Dimensions Shielding Case Connection: D5A, D12A and D24E Models D48A and D48E Models Case Material 4.7-7.25 Volts (5V nominal) 9-18 Volts (12V nominal) 18-36Volts (24V nominal 18-75 Volts (48V nominal) 36-72 Volts (48V nominal) See Ordering Guide Pi None 20 Volts 40 Volts 76 Volts Yes (Instantaneous, 6A maximum)
Absolute Maximum Ratings
Input Voltage: D5A Models D12A Models D24E Models D48A and D48E Models Input Reverse-Polarity Protection Output Overvoltage Protection 5/5.2V Outputs 12V Outputs 15V Outputs Output Current
10 Volts 22 Volts 44 Volts 80 Volts Current must be <6A. Brief duration only. Fusing recommended. 6.8 Volts, limited duration 15 Volts, limited duration 18 Volts, limited duration Current limited. Max. current and short-circuit duration model dependent. ­40 to +105°C +300°C
Output
±1%, maximum ±0.02% per °C See Ordering Guide See Ordering Guide See Ordering Guide 1500Vdc, guaranteed 250pF Auto-recovery Zener/transorb clamp, magnetic feedback
Storage Temperature Lead Temperature (soldering, 10 sec.)
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied.
TECHNICAL NOTES
Floating Outputs Since these are isolated DC/DC converters, their outputs are "floating." Designers will usually use the output Common (pin 5) as the ground/return of the load circuit. You can, however, use the +Output (pin 3) as ground/return to effectively reverse the output polarity. Filtering and Noise Reduction All A-Series UWR 6-10 Watt DC/DC Converters achieve their rated ripple and noise specifications without the use of external input/output capacitors. In critical applications, input/output ripple and noise may be further reduced by installing electrolytic capacitors across the input terminals and/or low-ESR tantalum or electrolytic capacitors across the output terminals. The caps should be located as close to the power converters as possible. Typical values are listed in the tables below. In many applications, using values greater than those listed will yield better results. To Reduce Input Ripple D5A Models D12A and D24E Models D48A and D48E Models To Reduce Output Ripple 5/5.2V Outputs 12/15V Outputs 47µF, 10V 20µF, 50V 10µF, 100V 47µF, 10V, Low ESR 22µF, 20V, Low ESR
Dynamic Characteristics
200µsec max. to ±1.5% of final value 165kHz (±15kHz)
Environmental
­40 to +60/65/70°C (Model dependent) to +100°C (See Derating Curves) ­40 to +105°C
Physical
2" x 1" x 0.375" (51 x 25 x 9.5mm) 5-sided Pin 2 (­VIN) Pin 1 (+VIN) Corrosion resistant steel with non-conductive, epoxy-based, black enamel finish and plastic baseplate Brass, solder coated 1.3 ounces (37 grams)
Pin Material Weight
These power converters require a minimum 10% loading to maintain specified regulation. Operation under no-load conditions will not damage these devices; however they may not meet all listed specifications. Application-specific input/output filtering can be recommended and perhaps added internally upon request. Contact DATEL Applications Engineering for details. Devices can be screened or modified for higher guaranteed isolation voltages. Contact DATEL Applications Engineering for details. Except for 3.3V devices which have no protection.
In critical, space-sensitive applications, DATEL may be able to tailor the internal input/output filtering of these units to meet your specific requirements. Contact our Applications Engineering Group for additional details.
3