Details, datasheet, quote on part number:PKF4910AR1A
 
 
Part:PKF4910AR1A
Category:Power Management => DC-DC Converters
Description:DC/DC Converter
Company:Ericsson Microelectronics
Datasheet:Download PKF4910AR1A datasheet   File size : 276 kB
Request For quote:  Find where to buy PKF4910AR1A
 



Datasheet text preview:
PKF 4910A I
DC/DC power modules 3.3 V / 3A / 9.9 W
· SMD and through-hole versions with ultra low component height 8.0 mm (0.315 in.) · 78% efficiency · 1,500 Vdc isolation voltage · Switching frequency syncronization · MTTF >10 million hours at +50°C case temperature · Low EMI
The MacroDensTM 9.9W PKF 4910A I true component level on-board DC/DC power modules are intended as distributed power sources in decentralized ­ 48 and ­ 60V DC power systems. They are optimized for an operational ambient temperature range in compliance with present and future application needs, including non temperature controlled environments.
The mechanical design offers the choice of surface mount or through-hole versions, delivered in readyto-use tubes, trays or tape & reel package, and compatibility with semi and fully aqueous cleaning processes. For mechanical and other information please refer to the PKF series General information data sheet.
E
Absolute Maximum Ratings
Characteristics TC TS VI V ISO Etr VRC Vadj Case temperature at full output power Storage temperature Continuous input voltage1) min ­45 ­55 ­0.5 1,500 0.01 ­5 ­5 +16 +40 max +100 +125 +75 Unit °C °C V dc V dc Ws V dc V dc
Isolation voltage (input to output test voltage) Transient input energy Remote control voltage pin 11 ref. to pin 17 Output adjust voltage pin 8 ref. to pin 17
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified m a n n e r.
Input TC Characteristics VI V Ioff VIon CI PIi PRC Input voltage range1)2) Conditions min 38 30.0 34.5 36.0 1.4 IO = 0, TC = ­30...+ 95 °C TC = ­ 3 0 ...+ 95 ° C , RC connected to pin 17 ( V I = 53V) ( V I = 66V) ( V I = 53V) ( V I = 66V) 25 40 310 310 typ max 72 36.0 38.0 Unit V V V mF mW
2)
Notes:
1)
Turn-off input voltage See typical characteristics Turn-on input voltage Input capacitance Input idling power Input stand-by power
See typical characteristics
The input voltage range 38...72 Vdc meets the European Telecom Standard prETS 300 132-2 Nominal input voltage range in 48V and 60 Vdc power systems, ­40.5...­57. 0V and ­50.0...­72.0V respectively. Absolute max continuous input voltage is 75 Vdc. The power modules will operate down to £35V, when VI decreases, but will turn on at VI £36V, when VI increases (see also Operating information).
mW
Connections
Pin 1 2 3-6 7 8 9 10 11 12­16 17 18 Designation Out 1 Rtn NC Sync Vadj NOR TOA RC NC ­IMn +In Function Output 1(+). Output return. Not connected. Galvanically Isolated from input pins. Synchronization input Output voltage adjust. Connection of Nominal Output voltage Resistor. Turn-on/off input voltage adjust. Remote control and turn-on/off input voltage adjust. Not connected. Galvanically isolated from input pins. Negative input. Positive input.
18 17 16 15 14 13 12 11 10
1
2
3
4
5
6
7
8
9
2
EN/LZT 146 86 R1A © Ericsson Microelectronics AB, December 2001
Safety
The PKF 4910A I DC/DC power module is designed in accordance with EN 60 950, Safety of information technology equipment including electrical business equipment. The PKF power modules are recognized by UL and meet the applicable requirements in UL 1950 Safety of information technology equipment, the applicable Canadian safety requirements and UL 1012 Standard for power supplies. The DC/DC power module shall be installed in an end-use equipment and considerations should be given to measuring the case temperature to comply with TC max when in operation. Abnormal component tests are conducted with the input protected by an external 15 A fuse. The need for repeating these tests in the enduse appliance shall be considered if installed in a circuit having higher rated devices. When the supply to the DC/DC power module meets all the requirements for SELV (<60Vdc), the output is considered to remain within SELV limits (level 3). The isolation is an operational insulation in accordance with EN 60 950. The DC/DC power module is intended to be supplied by isolated secondary circuitry and shall be installed in compliance with the requirements of the ultimate application. If they are connected to a 60 V DC system reinforced insulation must be provided in the power supply that isolates the input from the mains. Single fault testing in the power supply must be performed in combination with the DC/DC power module to demonstrate that the output meets the requirement for SELV. One pole of the input and one pole of the output is to be grounded or both are to be kept floating. The terminal pins are only intended for connection to mating connectors of internal wiring inside the end-use equipment. These DC/DC power modules may be used in telephone equipment in accordance with paragraph 34 A.1 of UL 1459 (Standard for Telephone Equipment, second edition). The galvanic isolation is verified in an electric strength test. Test voltage (VISO) between input and output is 1,500 Vdc for 60 s. In production the test duration may be decreased to 1 s. The capacitor between input and output has a value of 1 nF and the leakage current is less than 1µA @ 53 Vdc. The case is designed in non-conductive epoxy. Its flammability rating meets UL 94V-0. The oxygen index is 34%.
Electrical Data
Fundamental circuit diagram, Single output
Transient input voltage
Single voltage pulse at +25°C ambient temperature.
EN/LZT 146 86 R1A © Ericsson Microelectronics AB, December 2001
3