Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:74136
 
 
Part:74136
Description:
Company:Fairchild Semiconductor
Datasheet:Download 74136 datasheet   File size : 45 kB
Request For quote:  Find where to buy 74136
 



Datasheet text preview:
DM74LS136 Quad 2-Input Exclusive-OR Gate with Open-Collector Outputs

October 1988 Revised March 2000

DM74LS136 Quad 2-Input Exclusive-OR Gate with Open-Collector Outputs
General Description
This device contains four independent gates, each of which performs the logic exclusive-OR function.

Ordering Code:
Order Number DM74LS136M DM74LS136N Package Number M14A N14A Package Description 14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150 Narrow 14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide

Devices also available in Tape and Reel. Specify by appending the suffix letter "X" to the ordering code.

Connection Diagram

Truth Table
Inputs A L L H H
H = HIGH Voltage Level L = LOW Voltage Level

Output B L H L H Z L H H L

© 2000 Fairchild Semiconductor Corporation

DS009819

www.fairchildsemi.com

DM74LS136

Absolute Maximum Ratings(Note 1)
Supply Voltage Input Voltage Operating Free Air Temperature Range Storage Temperature Range 7V 7V 0°C to +70°C -65°C to +150°C
Note 1: The "Absolute Maximum Ratings" are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum ratings. The "Recommended Operating Conditions" table will define the conditions for actual device operation.

Recommended Operating Conditions
Symbol VCC VIH VIL IOL TA Supply Voltage HIGH Level Input Voltage LOW Level Input Voltage LOW Level Output Current Free Air Operating Temperature 0 Parameter Min 4.75 2 0.8 8 70 Nom 5 Max 5.25 Units V V V mA °C

Electrical Characteristics
Over recommended operating free air temperature range (unless otherwise noted) Symbol VI IC E X VOL Parameter Input Clamp Voltage HIGH Level Output Current LOW Level Output Voltage II IIH IIL ICC Input Current @ Max Input Voltage HIGH Level Input Current LOW Level Input Current Supply Current Conditions VCC = Min, II = -18 mA VCC = Min, VO = 5.5V VCC = Min, IOL = Max VIH = Min IOL = 4 mA, VCC = Min VCC = Max, VI = 7V VCC = Max, VI = 2.7V VCC = Max, VI = 0.4V VCC = Max 0.35 0.25 Min Typ (Note 2) Max -1.5 100 0.5 0 .4 0.2 40 -0.6 10 mA µA mA mA Units V µA V

Note 2: All typicals are at VCC = 5V, TA = 25°C. Note 3: Not more than one output should be shorted at a time, and the duration should not exceed one second.

Switching Characteristics
at VCC = 5V and TA = 25°C RL = 2 k Symbol Parameter Min tPLH tPHL Propagation Delay Time LOW-to-HIGH Level Output Propagation Delay Time HIGH-to-LOW Level Output CL = 15 pF Max 23 23 ns ns Units

www.fairchildsemi.com

2

DM74LS136

Physical Dimensions inches (millimeters) unless otherwise noted

14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-120, 0.150 Narrow Package Number M14A

3

www.fairchildsemi.com

DM74LS136 Quad 2-Input Exclusive-OR Gate with Open-Collector Outputs

Physical Dimensions inches (millimeters) unless otherwise noted (Continued)

14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300 Wide Package Number N14A

Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and Fairchild reserves the right at any time without notice to change said circuitry and specifications. LIFE SUPPORT POLICY FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. www.fairchildsemi.com 4 2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.fairchildsemi.com