POWER RELAY
1 POLE--5 A (MEDIUM LOAD CONTROL)
VE SERIES
s FEATURES
q q q
q q q
q
UL, CSA, VDE recognized 1 form A (SPST-NO) or 1 form C (SPDT) contact Low cost, miniature relay with big performance in small package --Surge strength: 4,000 V or 6,000 V Slim type--meets high density mounting requirement Wide operating range Easy circuit design with completely separated terminal arrangement (coil and contact terminals) Plastic sealed type
s ORDERING INFORMATION
[Example]
(a) (b) (c) (d) ( e) (f )
V E ­ 12 (a) (*) (b)
H (c)
M (d)
S (e)
E ­ K ­ HV ­ VD (f ) (g) (h) (i)
VE : VE Series Refer to the COIL DATA CHART H : Heavy duty type Nil : 1 form C (SPDT) M : 1 form A (SPST-NO) Nil : Standard type S : High sensitivity type Nil : Gold overlay silver-nickel (N.C.: 3 A, N.O.: 5 A) E : Silver-nickel (N.C.: 3 A, N.O.: 5 A) 5 : Silver cadmium oxide (N.C.: 5 A, N.O.: 5 A) K : Plastic sealed type Nil : Standard type (4,000 V) HV: High dielectric strength type (6,000 V) VD: UL, CSA, VDE approved type
Series Name Nominal Voltage Contact Rating Contact Arrangement Coil Type Contact Material (Rating)
(g) (h) (i)
Enclosure Surge Strength Standard
Note: Actual marking omits the hyphen (-) of (*)
1
VE SERIES
s SAFETY STANDARD AND FILE NUMBERS
UL508 (File No. E56140) C22.2 No. 14 (File No. LR35579) VDE 0435 (File No. 11039-4940-1011) Please note that UL/CSA ratings may differ from the standard ratings.
Type VE-H Nominal voltage 5 to 48 VDC Contact rating Normally open: 1/14 HP 125 VAC/250 VAC 5 A 30 VDC/250 VAC, resistive Pilot duty D300 Normally close: 1/14 HP 125 VAC/250 VAC 3 A 30 VDC/250 VAC, resistive Pilot duty D150 1/12 HP 125 VAC/250 VAC 5 A 30 VDC/250 VAC, resistive Pilot duty D300 Normally open: 1/10 HP 125 VAC/250 VAC 5 A 30 VDC/250 VAC, resistive Pilot duty D300 Normally close: 1/14 HP 125 VAC/250 VAC 5 A 30 VDC/250 VAC, resistive
VE-HM
5 to 48 VDC
VE-H5 VE-HM5
5 to 48 VDC
2
VE SERIES
s SPECIFICATIONS
Item Contact Arrangement Material Style Resistance (initial) (at 1 A 6 VDC) Rating (resistive) Maximum Carrying Current Maximum Switching Power Maximum Switching Voltage Maximum Switching Current Minimum Switching Load*1 Coil Nominal Power (at 20°C) Operate Power (at 20°C) Operating Temperature Time Value Operate (at nominal voltage) Release (at nominal voltage) Insulation Resistance (at 500 VDC) between open contacts VE-( ) HME-K VE-( ) HM-K VE-( ) HE-K VE-( ) H-K VE-( ) HM5-K 1 form A (SPST-NO) VE-( ) H5-K 1 form C (SPDT)
1 form A (SPST-NO) 1 form C (SPDT)
Gold overlay silver nickel, silver nickel Silver-cadmium oxide alloy Single Maximum 70 m (VE-HM, H) Maximum 100 m (VE-HME, HE) 5 A 250 VAC 7A 1,250 VA 1,250 VA (N.O.) 750 VA (N.C.) 1,250 VA 5 A 250 VAC (N.O.) 3 A 250 VAC (N.C.) Maximum 200 m 5 A 250 VAC
250 VAC, 150 VDC 5A 5 A (N.O.) 3 A (N.C.) 5A
10 mA, 5 VDC (VE-HM, H), 100 mA 5 VDC (VE-HME, HE, HM5, H5) Standard type: 0.36 W. High sensitivity type: 0.25 W Standard type: 0.177 W. High sensitivity type: 0.13 W Standard: ­40°C to +85°C. High sensitivity: ­40°C to +90°C (no frost) Maximum 10 ms Maximum 5 ms Minimum 1,000 M 1,000 VAC 1 minute 750 VAC 1 minute 1,000 VAC 1 minute 750 VAC 1 minute 2,000 VAC 1 minute Standard type: 4,000 V (at 2 x 10 µs) High dielectric strength type: 6,000 V (at 2 × 10 µs) 1 × 107 operations minimum Standard Type: 1 × 105 ops. min. High sensitivity type: 5 x 104 ops. min. 10 to 55 Hz (double amplitude of 3.3 mm) 10 to 55 Hz (double amplitude of 3.3 mm) 100 m/s2 (11 ±1 ms) 500 m/s2 (6 ±1 ms) Approximately 8 g
Dielectric Strength between coil and contacts Surge Strength Life Mechanical Electrical (at Rating) Other Vibration Resistance Shock Resistance Weight
Misoperation Endurance Misoperation Endurance
*1 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.