POWER RELAY
1 POLE--3A to 5 A (CADMIUM FREE CONTACTS TYPE)
VG SERIES
s FEATURES
q q q
q q
q q
UL, CSA recognized, TV-5 rated 1 form A (SPST-NO) or 1 form C (SPDT) contact Reliable, low power consumption miniature power relay --Surge strength 7,000 V Slim type--meets high density mounting requirement Easy circuit design with completely separated terminal arrangement (coil and contact terminals) Plastic sealed type backfilled with nitrogen available Environmentally friendly cadmium free contact type is available
s ORDERING INFORMATION
[Example]
(a) (b) (c)
V G 12 (a) (*) (b)
Series Name
Nominal Voltage Contact Rating
(d) ( e) (f )
Contact Arrangement Coil Type
Contact Material (Rating)
DI SC ON TIN UE D
H (c) M (d) S (e) E K UL (f ) (g) (h)
VG: VG Series Refer to the COIL DATA CHART Nil : 3 A H : 5A T : 5 A (only TV-5) Nil : 1 form C (SPDT) M : 1 form A (SPST-NO) Nil : Standard type S : High sensitivity type (only 3 A type available) Nil : Gold overlay silver-nickel (3 A, 5 A) Nil : Silver alloy (only TV-5) E : Silver-nickel (3 A, 5 A) Nil : Flux free type C : Plastic sealed type (with tape) K : Plastic sealed type UL : UL, CSA approved type
(g)
Enclosure
(h)
Standard
Note: Actual marking omits the hyphen (-) of (*)
1
VG SERIES
s SAFETY STANDARD AND FILE NUMBERS
UL508, 873 (File No. E56140) C22.2 No. 1, No. 14 (File No. LR35579) Please note that UL/CSA ratings may differ from the standard ratings.
Type TV-Rating VG-TM Nominal voltage 5 to 48 VDC Contact rating TV-5 120 VAC 1/8 HP 120 VAC/240 VAC 5 A 24 VDC/240 VAC resistive (*) Pilot duty C 150 1/8 HP 120 VAC/240 VAC 5 A 24 VDC/120 VAC resistive Pilot duty C 150 1/10 HP 120 VAC/240 VAC 3 A 30 VDC/120 VAC resistive Pilot duty D 150
General
VG-H
5 to 48 VDC
*
Only UL approval
DI SC ON TIN UE D
VG 5 to 48 VDC
2
VG SERIES
s SPECIFICATIONS
Standard Type Item TV-5 Type VG-( ) TM Contact Arrangement Material Style Resistance (initial) (at 1 A 6 VDC) Rating (resistive) Maximum Carrying Current Maximum Switching Power 1 form A (SPST-NO) Silver alloy Single Maximum 200 m Maximum 70 m (VG-H,VG), Max. 100 m (VG-HE, E) 5 A 120 VAC 5 A 24 VDC 5A 3 A 120 VAC 3 A 30 VDC 5 A Type VG-( ) H VG-( ) HE 3 A Type VG VG-E High Sensitive Type 3 A Type VG-S VG-SE
1 form A (SPST-NO) or 1 form C (SPDT) Gold overlay silver alloy (VG-H, VG), silver alloy (VG-HE,E)
Coil
Time Value
Insulation
Life
Other
DI SC ON TIN UE D
1,000 VA, 150 W 500 VA, 90 W Maximum Switching Voltage Maximum Switching Current Minimum Switching Load*1 250 VAC, 150 VDC 5A 3A 10 mA 5 VDC (VG-H,VG), 100 mA 5 VDC (VG-TM,VG-HE, E) Nominal Power (at 20°C) 0.36 to 0.4 W Operate Power (at 20°C) Operating Temperature 0.18 to 0.2 W 40°C to +70°C (no frost) Operate (at nominal voltage) Maximum 10 ms Maximum 5 ms Release (at nominal voltage) Resistance (at 500 VDC) Minimum 1,000 M Dielectric Strength between open contacts 900 VAC 1 minute 750 VAC 1 minute between coil and contacts 4,000 VAC 1 minute Surge Strength 7,000 V (at 1.2 × 50 µs) Mechanical Electrical 1 × 107 operations minimum 1 × 105 operations minimum (at contact rating) 10 to 55 Hz (double amplitude of 1.5 mm) 100 m/s2 (11 ±1 ms) 1,000 m/s2 (6 ±1 ms) Approximately 12 g Vibration Resistance Shock Resistance Weight Misoperation Endurance Misoperation Endurance 10 to 55 Hz (double amplitude of 1.5 mm)
0.21 to 0.26 W
0.102 to 0.13 W
40°C to +85°C (no frost)
*1
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.