Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:VH
 
 
Part:VH
Category:Discrete => Solid State relays
Description:
Company:Fujitsu Microelectronics, Inc.
Datasheet:Download VH datasheet   File size : 89 kB
Request For quote:  Find where to buy VH
 



Datasheet text preview:
POWER RELAY
1 POLE--16 A
(CADMIUM FREE CONTACTS TYPE)
VH SERIES
s FEATURES
q q q
q
q q
UL, CSA recognized TV-10 rated 1 Form A (SPST-NO) contact Heavy duty 16 A small power relay with tab-terminals (#250) High inrush current and high surge voltage --Inrush Current 55 A --Surge Strength 7,000 V Small package meets high density mounting requirement Environmentally friendly cadmium free contact type is available
NO
V H ­ 12 (a) (*) (b)
s ORDERING INFORMATION
[Example]
DE
TF SI
(a) (b)
Series Name Nominal Voltage
VH : VH Series
Refer to the COIL DATA CHART
Actual marking omits the hyphen (-) of (*)
NE GN W S
Contact rating TV-10 120 VAC 1 HP 125 VAC/250 VAC 16 A 125 VAC resistive Pilot duty A 150
OR
s SAFETY STANDARD AND FILE NUMBERS
UL508, 873 (File No. E56140,E108658) C22.2 No. 1, No. 14 (File No. LR35579) Please note that UL/CSA rating may differ from the standard rating. Please request when the approval markings are required on the cover.
Type Nominal voltage
VH
5 to 60 VDC
1
VH SERIES
s SPECIFICATIONS
Item Contact Arrangement Material Style Resistance (initial) Ratings (resistive) Maximum Carrying Current 1 form A (SPST-NO) Silver-alloy Single Maximum 30 m (at 1 A 6 VDC) 16 A 250 VAC 20 A 4,000 VA 380 VAC 16 A 100 mA 5 VDC VH
Coil
NO
Minimum Switching Surge Strength Mechanical Electrical
Maximum Switching Power Maximum Switching Voltage Maximum Switching Current Load*1
Nominal Power (at 20°C)
Operate Power (at 20°C) Operating Temperature Time Value
Operate (at nominal voltage)
Release (at nominal voltage) Insulation Resistance (at 500 VDC)
between open contacts 1,000 VAC 1 minute Dielectric Strength between coil and contacts 4,000 VAC 1 minute
DE
Endurance Endurance
TF SI
0.9 to 1.0 W 0.45 to 0.5 W ­30°C to +70°C (no frost)
Maximum 15 ms
Maximum 5 ms
Minimum 1,000 M
Life
Other
Vibration Resistance Shock Resistance Unit Mass
Misoperation
Misoperation
NE GN W S
7,000 V (at 1.2 × 50 µs) 5× 106 105 operations minimum 2× operations minimum (contact rating) 10 to 55 Hz (double amplitude of 3 mm) 10 to 55 Hz (double amplitude of 3 mm) 200 m/s2 (11 ±1 ms) 1,000 m/s2 ( 6 ±1 ms) Approximately 35 g
OR
*1
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels.
2
VH SERIES
s COIL DATA CHART
MODEL VH- 5 VH- 6 VH- 9 VH-12 VH-18 VH-24 VH-48 VH-60 Nominal voltage 5 VDC 6 VDC 9 VDC 12 VDC 18 VDC 24 VDC Coil resistance (±10%) 28 40 90 160 360 640 2,300 3,600 Must operate voltage 3.5 VDC 4.2 VDC 6.3 VDC 8.4 VDC 12.6 VDC 16.8 VDC 33.6 VDC 42.0 VDC Must release voltage 0.25 VDC 0.3 VDC 0.45 VDC 0.6 VDC 0.9 VDC 1.2 VDC 2.4 VDC 3.0 VDC Nominal power 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 0.9 W 1.0 W 1.0 W
Note: All values in the table are measured at 20°C
s CHARACTERISTIC DATA
NO
48 VDC 60 VDC
DE
TF SI
NE GN W S
OR
3