Datasheet text preview:
*(1/,1; TM,, GS9035A
S er ial Digital Reclocker
DATA SHEET FE ATURE S · adjustment-free operation · auto-rate selection for 5 SMPTE data rates: 143, 177, 270, 360, 540Mb/s · data rate indication output · serial data output mute when PLL is not locked · immune to harmonic locking · operation independent of SAV/EAV sync signals · low jitter, low power · single external VCO resistor for operation with five input data rates · large input jitter tolerance: typically 0.45 UI beyond loop bandwidth · power savings mode (output serial clock disable) · system friendly: serial clock remains active when data outputs muted · robust lock detect APP LI CATI O N S The GS9035A is used for Clock and Data recovery, and Jitter elimination for all high speed serial digital interface applications involving SMPTE 259M and other data standards. D E S C R I P TI O N The GS9035A is a high performance clock and data recovery IC designed for serial digital data. The GS9035A receives either single-ended or differential PECL data and outputs differential PECL clock and retimed data signals. The GS9035A can operate in either auto or manual rate selection mode. In auto mode the GS9035A is ideal for multi-rate serial data protocols such as SMPTE 259M. In this mode the GS9035A automatically detects and locks onto the incoming data signal. For single rate data systems, the GS9035A can be configured to operate in manual mode. In both modes, the GS9035A requires only one external resistor to set the VCO centre frequency and provides adjustment-free operation. The GS9035A has dedicated pins to indicate LOCK and data rate. In addition, an internal muting function forces the serial data outputs to a static state when input data is not present or when the PLL is not locked. The serial clock outputs can also be disabled resulting in a 10% power savings. The GS9035A is packaged in a 28 pin PLCC and operates from a single +5 or -5 volt power supply. ORDERING O RDE RI N G INFORMATION
PART NUMBER PACKAGE TEMPERATURE
GS9035A
GS9035ACPJ GS9035ACTJ
28 pin PLCC 28 pin PLCC Tape
0°C to 70°C 0°C to 70°C
COSC
CARRIER DETECT PHASELOCK HARMONIC LOGIC
LOCK
SDO FREQUENCY ACQUISITION
2
SDO PHASE DETECTOR CLK_EN SCO SCO DIVISION 3 BIT COUNTER SMPTE AUTO/MAN
DDI/DDI
CHARGE PUMP
VCO
DECODER
SSO SS1 SS2
LF+ LFS LF-
CBG
RVCO
BLOCK DIAGRAM B LO C K
Revision Date: May 2003 GENNUM CORPORATION P.O. Box 489, Stn. A, Burlington, Ontario, Canada L7R 3Y3 Tel. +1 (905) 632-2996 Fax. +1 (905) 632-5946 E-mail: info@gennum.com www.gennum.com Document No. 522 - 41 - 07
ABS O LUTE MAXIMUM RATINGS
PARAMETER VALUE
Supply Voltage (VS) Input Voltage Range (any input) Operating Temperature Range Storage Temperature Range Lead Temperature (soldering, 10 sec)
5.5V VCC + 0.5 to VEE - 0.5V 0°C TA 70°C -65°C TS 150°C 260°C
GS9035A
DC ELECTRICAL CHARACTERISTICS
VCC = 5.0V, VEE = 0V, TA = 0° ­ 70°C unless otherwise stated, RLF = 1.8K, CLF1 = 15nF, CLF2 = 3.3pF.
PARAMETER
CONDITION
MIN
TYPICAL
1
MA X
UNITS
NOTES
TEST LEVEL
Supply Voltage Supply Current CLK_EN = 0 CLK_EN = 1 DDI/DDI Common Mode Input Voltage Range DDI/DDI Differential Input Drive AUTO/MAN, SMPTE High Low CLK_EN Input Voltage High Low LOCK Output Low Voltage SS{2:0} Output Voltage
4.75 VEE + (VDIFF/2) 200 2.0 2.5 4.4
5.00 90 105 0.4 to 4.6 800 0.25 4.8
5.25 110 120 VCC - (VDIFF/2) 2000 0.8 0.8 0.4 -
V mA mA V mV V 2
3 3 3 3 3 3
V
3
OH = 500µA HIGH, OH = -180µA, Auto Mode
LOW, OL = 600µA, Auto Mode
V V
3
1 1
-
0.3
0.4
SS{2:0} Input Voltage
HIGH, Manual Mode LOW, ManualMode
2 -
26
0.8 55
V
3
CLK_EN Source Current
Low, VIL = 0V
µA
1
NOTES 1. TYPICAL - measured on EB-RD35A board. 2. VDIFF is the differential input signal swing. 3. LOCK is an open collector output and requires an external pull-up resistor. 4. Pins SS[2:0] are outputs in AUTO mode and inputs in MANUAL mode.
TEST LEVELS 1. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges. 2. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges using correlated test. 3. Production test at room temperature and nominal supply voltage. 4. QA sample test. 5. Calculated result based on Level 1,2, or 3. 6. Not tested. Guaranteed by design simulations. 7. Not tested. Based on characterization of nominal parts.
2 of 14
GENNUM CORPORATION 522 - 41 - 07
AC ELECTRICAL CHARACTERISTICS
VCC = 5.0V, VEE = 0V, TA = 0° ­ 70°C unless otherwise stated, RLF = 1.8K, CLF1 = 15nF, CLF2 = 3.3pF 1
PARAMETER
CONDITION
M IN
TYPICAL
MAX
UNITS
NOTES
TEST LEVEL
Serial Data Rate Intrinsic Jitter Psuedorandom (223 - 1) Intrinsic Jitter Pathological (SDI checkfield) Input Jitter Tolerance
SDI 270Mb/s 540Mb/s 270Mb/s 360Mb/s 540Mb/s 270Mb/s 540Mb/s
143 0.40 0.35 0.5 -200
185 164 462 308 260 0.56 0.43 1 1 4 10 1 0 800 300
540 See Figure 6
Mb/s ps p-p 2
3 4
GS9035A
See Figure 7
ps p-p
2
3
2 200 1000 400
UI p-p
3
9
Lock Time Synchronous Switch
tSWITCH 10ms
µs ms ms ms µs ps mV p-p ps
4
7
Lock Time Asynchronous Switch SDO MUTE Time SDO to SCO Synchronization SDO, SCO Output Signal Swing SDO, SCO Rise and Fall Times
Loop Bandwidth = 6MHz at 540 Mb/s
5 6
7 7 7 1 7
75 DC load 20% - 80%
600 200
NOTES 1. TYPICAL - measured on EB-RD35A board, TA = 25°C. 2. Characterized 6 sigma rms. 3. IJT measured with sinusoidal modulation beyond Loop Bandwidth (at 6.5MHz). 4. Synchronous switching refers to switching the input data from one source to another source which is at the same data rate (ie: line 10 switching for component NTSC). 5. Asynchronous switching refers to switching the input data from one source to another source which is at a different data rate. 6. SDO MUTE Time refers to the response of the SDO output from valid re-clocked input data to mute mode when the input signal is removed. TEST LEVEL 1. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges. 2. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges using correlated test. 3. Production test at room temperature and nominal supply voltage. 4. QA sample test. 5. Calculated result based on Level 1,2, or 3. 6. Not tested. Guaranteed by design simulations. 7. Not tested. Based on characterization of nominal parts. 8. Not tested. Based on existing design/characterization data of similar product. 9. Indirect test
3 of 14