Details, datasheet, quote on part number:HX9100
| |
Datasheet text preview:
Military & Space Products
Advance Information
64 X 64 CROSSBAR
FEATURES
· Fabricated with RICMOSTM IV Silicon on Insulator (SOI)0.8 µm Process (Leff = 0.65 µm) · CMOS Compatible I/O · Single 5V + 10% Power Supply · Full Complement of Screening Flows · Supports System Speeds Beyond 100 MHz · Skew <2 ns
HX9100
· Total Dose Hardness of 1x106 rad(SiO2) · Dose Rate Upset Hardness 1x1011 rad(Si)/sec (5V) · Dose Rate Survivability 1x1012 rad(Si)/sec · SEU Immunity <1x10-11 Errors/Bit-Day · Neutron Fluence Hardness to 1x1014/cm2 · No Latchup
GENERAL DESCRIPTION
The HX9100 is a radiation hardened 64 x 64 crossbar switch that allows connecting any of 64 output channels to any of 64 input channels. Switching is controlled by a set of Connection Registers whose value can be set or read out by using the control lines. There is an installed Connection Register for each output channel which determines which input channel is connected through the crossbar switch matrix to that output channel. There is also a Setup Connection Register for each output channel that may be used to setup the next connection to be made for that simultaneously into the Installed Connection Registers into change the routing through the crossbar switch matrix. This two-stage design allows a number of Setup Connection Registers to be changed sequentially and then moved simultaneously to the Installed Connection Registers so all of the new connections are made at the same time. If no change has been made to the Setup Connection Register for a channel, there is no change in the connection of that output channel when the Setup Connection Register contents are transferred to the Installed Connection Registers. Data_ In and Data_Out channels are each divided into a set of 21 three wire ports, each port consisting of a Clock channel, a Data channel and a Sync channel. One designated "extra" input channel and output channel are not considered part of any port. There is also a set of 21 twobit Pipeline Registers, one for each output port, which optionally allows resynchronizing the Data and Sync channels of a port to the Clock channel for that port. When pipelining is activated, using the Pipeline control line, the contents of the Data and Sync lines are latched in the Pipeline Register on the negative-going transition of the Clock channel for that port. When pipelining is not activated, the Clock, Data and Sync channels are passed directly to the Data_Out lines without being latched.
Functional Diagram
64 Input Channels
64 Output Channels Pipeline Circuit
21 Input Ports of 3 Channels Each
· · ·
64 x 64 Crossbar Switch Matrix
· · ·
Pipeline Circuit Pipeline Circuit
21 Output Ports of 3 Channels Each Extra Output Channel
Extra Input Channel Pipeline 64 x 6
Address Setup/install_ n Chip_ Select_ n Write_ Enable_ n Output Enable_n
6
Installed Connection Registers
6
4 64 x 6 Setup Connection Registers 6
Control_ Data
6
Reset_ n
HX9100
256-LEAD FLAT PACK PACKAGE
INDEX CORNER AND TERMINAL NO. 1 ID AREA 256
HD/HE D/E e1 4 PLACES
A A1
193
Dimensions in inches min max 0.130 0.160 A 0.130 A1 0.024 0.040 A2 0.005 0.009 b 0.004 0.008 c D/E 1.445 1.455 0.020 BSC e 1.260 BSC e1 HD/HE2.365 2.395 0.325 L 256 N
1 L 4 PLACES
192
e N-4 PLACES 64 NON-CONDUCTIVE TIE BAR: 4 PLACES 65 128 129
OPTIONAL CAPACITOR SITE: 8 PLACES
b N PLACES
c A2
ORDERING INFORMATION (1) H
SOURCE H=HONEYWELL
X
PROCESS X=SOI
9100
PART NUMBER
S
SCREEN LEVEL V=QML Class V Q=QML Class Q S=Level S B=Level B E=Engr Device (2)
H
TOTAL DOSE HARDNESS F=3x105 rad(SiO2) H=1x106 rad(SiO2) N=No Level Guaranteed
(1) Orders may be faxed to 612-954-2051. Please contact our Customer Logistics Department at 612-954-2888 for further information. (2) Engineering Device description: Parameters are tested from -55 to 125°C, 24 hr burn-in, no radiation guaranteed. Contact Factory with other needs.
To learn more about Honeywell Solid State Electronics Center, visit our web site at http://www.ssec.honeywell.com
Honeywell reserves the right to make changes to any products or technology herein to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others.
Helping You Control Your World
900173 3/96
|
|