Part: IRF3709Z
Category:
Description: 30V Single N-channel HexFET Power MOSFET in a TO-220AB Package
Company: International Rectifier Corp.
Datasheet: Download IRF3709Z datasheet File size : 120 kB
Request For quote: Find where to buy IRF3709Z
Datasheet text preview:
Applications l High Frequency Synchronous Buck Converters for Computer Processor Power
HEXFET® Power MOSFET
IRF3709Z IRF3709ZS IRF3709ZL
Qg
17nC
PD - 95835
VDSS RDS(on) max
30V 6.3m:
Benefits l Low RDS(on) at 4.5V VGS l Low Gate Charge l Fully Characterized Avalanche Voltage and Current
TO-220AB IRF3709Z
D2Pak IRF3709ZS
TO-262 IRF3709ZL
Absolute Maximum Ratings
Parameter
VDS V GS ID @ TC = 25°C ID @ TC = 100°C I DM PD @TC = 25°C PD @TC = 100°C TJ TS T G Drain-to-Source Voltage Gate-to-Source Voltage Continuous Drain Current, VGS @ 10V Continuous Drain Current, VGS @ 10V Pulsed Drain Current
Max.
30 ± 20 87 62
Units
V A
c
h h
350 79 40 0.53 -55 to + 175 300 (1.6mm from case) 10 lbfyin (1.1Nym) W/°C °C W
Maximum Power Dissipation Maximum Power Dissipation Linear Derating Factor Operating Junction and Storage Temperature Range Soldering Temperature, for 10 seconds Mounting Torque, 6-32 or M3 screw
Thermal Resistance
Parameter
RJC RJA Junction-to-Case
i
Typ.
Max.
1.89 40
Units
°C/W
Junction-to-Ambient (PCB Mount)
g
Notes through are on page 12
www.irf.com
1
1/16/04
IRF3709Z/S/L
Static @ TJ = 25°C (unless otherwise specified)
Parameter
BVDSS VDSS/TJ RDS(on) VGS(th) VGS(th)/TJ IDSS IGSS gfs Qg Qgs1 Qgs2 Qgd Qgodr Qsw Qoss td(on) tr td(off) tf Ciss Coss Crss Drain-to-Source Breakdown Voltage Breakdown Voltage Temp. Coefficient Static Drain-to-Source On-Resistance Gate Threshold Voltage Gate Threshold Voltage Coefficient Drain-to-Source Leakage Current Gate-to-Source Forward Leakage Gate-to-Source Reverse Leakage Forward Transconductance Total Gate Charge Pre-Vth Gate-to-Source Charge Post-Vth Gate-to-Source Charge Gate-to-Drain Charge Gate Charge Overdrive Switch Charge (Qgs2 + Qgd) Output Charge Turn-On Delay Time Rise Time Turn-Off Delay Time Fall Time Input Capacitance Output Capacitance Reverse Transfer Capacitance
Min. Typ. Max. Units
30 1.35 88 0.021 5.0 6.2 -5.5 17 4.4 1.7 6.0 4.9 7.7 11 13 41 16 4.7 2130 450 220 6.3 7.8 2.25 1.0 150 100 -100 26 pF VGS = 0V VDS = 15V ns nC nC VDS = 15V VGS = 4.5V ID = 17A S nA V mV / °C µA V
Conditions
VGS = 0V, ID = 250µA
mV/°C Reference to 25°C, ID = 1mA m VGS = 10V, ID = 21A VGS = 4.5V, ID = 17A
e e
VDS = VGS, ID = 250µA VDS = 24V, VGS = 0V VDS = 24V, VGS = 0V, TJ = 125°C VGS = 20V VGS = -20V VDS = 15V, ID = 17A
See Fig. 14a&b VDS = 16V, VGS = 0V VDD = 15V, VGS = 4.5V ID = 17A Clamped Inductive Load
e
= 1.0MHz
Avalanche Characteristics
EAS IAR EAR Parameter Single Pulse Avalanche Energyd Avalanche Currentà Repetitive Avalanche Energy Typ. Max. 60 17 7.9 Units mJ A mJ
16 6.2
Diode Characteristics
Parameter
IS ISM VSD t rr Qrr Continuous Source Current (Body Diode) Pulsed Source Current (Body Diode)Ã Diode Forward Voltage Reverse Recovery Time Reverse Recovery Charge
Min. Typ. Max. Units
87
h
Conditions
MOSFET symbol
D
A 350 1.0 24 9.3 V ns nC
showing the integral reverse
G S
p-n junction diode. TJ = 25°C, IS = 17A, VGS = 0V TJ = 25°C, IF = 17A, VDD = 15V di/dt = 100A/µs
e
e
2
www.irf.com
IRF3709Z/S/L
1000
T OP VGS 10V 9.0V 7.0V 5.0V 4.5V 4.0V 3.5V 3.0V
1000
T OP VGS 10V 9.0V 7.0V 5.0V 4.5V 4.0V 3.5V 3.0V
ID, Drain-to-Source Current (A)
BOTTOM
ID, Drain-to-Source Current (A)
100
BOTTOM
100
3.0V
10
3.0V
60µs PULSE WIDTH
10 0.1 1 Tj = 25°C 1 100 0.1 1 10
60µs PULSE WIDTH
Tj = 175°C 10 100
V DS, Drain-to-Source Voltage (V)
V DS, Drain-to-Source Voltage (V)
Fig 1. Typical Output Characteristics
Fig 2. Typical Output Characteristics
1000
RDS(on) , Drain-to-Source On Resistance (Normalized)
2.0
ID, Drain-to-Source Current ()
ID = 42A VGS = 10V
100
T J = 175°C
1.5
10
1.0
1
T J = 25°C VDS = 15V 60µs PULSE WIDTH 0 1 2 3 4 5 6 7 8
0.1
0.5 -60 -40 -20 0 20 40 60 80 100 120 140 160 180
VGS, Gate-to-Source Voltage (V)
T J , Junction Temperature (°C)
Fig 3. Typical Transfer Characteristics
Fig 4. Normalized On-Resistance vs. Temperature
www.irf.com
3
Others parts begin by ir
IR-1 IR-2 IR-3 IR-4 IR-5 IR-6 IR-7 IR-8 IR-9 IR-10 IR-11 IR-12 IR-13 IR-14 IR-15 IR-16 IR-17 IR-18 IR-19 IR-20 IR-21 IR-22 IR-23 IR-24 IR-25 IR-26 IR-27 IR-28 IR-29 IR-30 IR-31
|
|
|