CDP1822, CDP1822C
256-Word x 4-Bit LSI Static RAM
Description
The CDP1822 and CDP1822C are 256-word by 4-bit static random-access memories designed for use in memory systems where high speed, low operating current, and simplicity in use are desirable. The CDP1822 features high speed and a wide operating voltage range. Both types have separate data inputs and outputs and utilize single power supplies of 4V to 6.5V for the CDP1822C and 4V to 10.5V for the CDP1822. Two Chip-Select inputs are provided to simplify system expansion. An Output Disable control provides Wire-OR capability and is also useful in common Input/Output systems. The Output Disable input allows these RAMs to be used in common data Input/Output systems by forcing the output into a high-impedance state during a write operation independent of the Chip-Select input condition. The output assumes a high-impedance state when the Output Disable is at high level or when the chip is deselected by CS1 and/or CS2. The high noise immunity of the CMOS technology is preserved in this design. For TTL interfacing at 5V operation, excellent system noise margin is preserved by using an external pull-up resistor at each input.
March 1997
Features
· Low Operating Current - VDD = 5V, Cycle Time 1µs . . . . . . . . . . . . . . . . . . 8mA · Industry Standard Pinout · Two Chip-Select Inputs-Simple Memory Expansion · Memory Retention for Standby Battery Voltage of 2V Minimum · Output-Disable for Common I/O Systems · Three-State Data Output for Bus-Oriented Systems · Separate Data Inputs and Outputs
Ordering Information
5V CDP1822CE 10V CDP1822E PACKAGE PDIP Burn-In SBDIP Burn-In -40oC to +85oC TEMP. RANGE -40oC to +85oC PKG. NO.
E22.4 E22.4 D22.4A D22.4A
CDP1822CEX CDP1822EX CDP1822CD CDP1822CDX CDP1822D -
Pinout
CDP1822, CDP1822C (PDIP, SBDIP) TOP VIEW
A3 1 A2 2 A1 3 A0 4 A5 5 A6 6 A7 7 VSS 8 DI1 9 DO1 10 DI2 1 1 22 VDD 21 A4 20 R/ W 19 CS1 18 O. D. 17 CS2 16 DO4 15 DI4 14 DO3 13 DI3 12 DO2
OPERATIONAL MODES INPUTS CHIP SELECT 1 (CS1) 0 0 0 CHIP SELECT 2 (CS2) 1 1 1 OUTPUT READ/ DISABLE WRITE (OD) (R/W) 0 0 1 1 0 0
M O DE R ead Write Write
OUTPUT Read Data In High Impedance High Impedance High Impedance High Impedance
Standby
1
X
X
X
Standby
X
0
X
X
Output Disable NOTE:
X
X
1
X
Logic 1 = High, Logic 0 = Low, X = Don't Care.
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a trademark of Intersil Americas Inc. Copyright © Intersil Americas Inc. 2001. All Rights Reserved
File Number
1074.2
11
CDP1822, CDP1822C
Absolute Maximum Ratings
DC Supply Voltage Range, (V DD) (All Voltages Referenced to VSS Terminal) CDP1822 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +11V CDP1822C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +7V Input Voltage Range, All Inputs . . . . . . . . . . . . . -0.5V to VDD +0.5V DC Input Current, Any One Input . . . . . . . . . . . . . . . . . . . . . . . . ±10mA
Thermal Information
Thermal Resistance (Typical) JA ( oC/W) JC (oC/W) PDIP Package . . . . . . . . . . . . . . . . . . . 75 N/A SBDIP Package. . . . . . . . . . . . . . . . . . 80 21 Maximum Operating Temperature Range (TA) Package Type D . . . . . . . . . . . . . . . . . . . . . . . . .-55oC to +125oC Package Type E . . . . . . . . . . . . . . . . . . . . . . . . . .-40oC to +85oC Maximum Junction Temperature Ceramic Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175oC Plastic Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150oC Storage Temperature Range (TSTG) . . . . . . . . . . .-65oC to +150oC TA = -40oC to +60oC (Package Type E) . . . . . . . . . . . . . . 500mW TA = +60oC to +85oC (Package Type E) . . . . . Der ate Linearly at . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12mW/oC to 200mW Lead Temperature (During Soldering) . . . . . . . . . . . . . . . . . . 300oC
Recommended Operating Conditions At TA = Full Package Temperature Range. For maximum reliability, operating conditions
should be selected so that operation is always within the following ranges: LIMITS CDP1822 PA RAME TER DC Operating Voltage Range Input Voltage Range SYMBOL MIN 4 VSS M AX 10.5 VDD MIN 4 VSS CDP1822C M AX 6.5 V DD UNITS V V
Static Electrical Specifications
At TA = -40oC to +85oC, Except as Noted CONDITIONS CDP1822 LIMITS CDP1822C (NOTE 1) TYP 4 -2 0 5 -
PARAMETER Quiescent Device Current Output Low (Sink) Current Output High (Source) Current Output Voltage Low-Level Output Voltage High-Level Input Low Voltage
SYMBOL IDD
VO (V) -
VIN (V) 0, 5 0, 10 0, 5 0, 10 0, 5 0, 10 0, 5 0, 10 0, 5 0, 10 0, 5 0, 10
VDD (V) 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10
MIN 2 4.5 -1 -2.2 4.9 9.9 3.5 7 -
(NOTE 1) TYP 4 9 -2 -4.4 0 0 5 10 -
M AX 500 1000 0.1 0.1 1.5 3 ±5 ±10
MIN 2 -1 4.9 3.5 -
M AX 500 0.1 1.5 ±5 -
UNITS µA µA mA mA mA mA V V V V V V V V µA µA
IOL
0.4 0.5
IOH
4.6 9.5
V OL
-
VOH
-
VIL
0.5, 4.5 0.5, 9.5
Input High Voltage
V IH
0.5, 9.5 0.5, 9.5
Input Leakage Current
IIN
-
12
CDP1822, CDP1822C
Static Electrical Specifications
At TA = -40oC to +85oC, Except as Noted (Continued) CONDITIONS CDP1822 VO (V) IOUT 0, 5 0, 10 C IN COUT VIN (V) 0, 5 0, 10 0, 5 0, 10 VDD (V) 5 10 5 10 (NOTE 1) TYP 4 8 5 10 LIMITS CDP1822C (NOTE 1) TYP 4 5 10
PARAMETE R Operating Current (Note 2) Three-S tate Output Leakage Current Input Capacitance Output Capacitance NOTES :
SYMBOL IDD1
MIN -
M AX 8 16 ±5 ±10 7.5 15
MIN -
M AX 8 ±5 7.5 15
UNITS mA mA µA µA pF pF
1. Typical values are for TA = +25oC and nominal VDD. 2. Outputs open circuited; Cycle time = 1µs.
Dynamic Electrical Specifications At TA + -40 to +85oC, VDD ±5%, Input t R, t F = 20ns, VIH = 0.7 VDD, VIL = 0.3 VDD ,
CL = 100 pF TEST CONDITIONS CD1822 VDD (V) (NOTE 1) MIN (NOTE 2) TYP (NOTE 1) MIN LIMITS CDP1822C (NOTE 2) TYP
PARAMETER Read Cycle Times (Figure 1) Read Cycle tRC
M AX
M AX
UNITS
5 10
450 250 20 20 20 20 20 20
250 150 250 150 250 150 -
450 250 450 250 450 250 200 110 -
450 20 20 20 -
250 250 250 -
450 450 450 200 -
ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
A ccess from Address
tAA
5 10
Output Valid from Chip-Select 1
tDOA1
5 10
Output Valid from Chip-Select 2
tDOA2
5 10
Output Valid from Output Disable tDOA3
5 10
Output Hold from Chip-Select 1
tDOH1
5 10
Output Hold from Chip-Select 2
tDOH2
5 10
Output Hold from Output Disable tDOH3
5 10
13
CDP1822, CDP1822C
Dynamic Electrical Specifications At TA + -40 to +85oC, VDD ±5%, Input t R, t F = 20ns, VIH = 0.7 VDD, VIL = 0.3 VDD ,
CL = 100 pF (Continued) TEST CONDITIONS CD1822 VDD (V) (NOTE 1) MIN (NOTE 2) TYP (NOTE 1) MIN LIMITS CDP1822C (NOTE 2) TYP
PA RAME TER NOTES :
M AX
M AX
UNITS
1. Time required by a limit device to allow for indicated function. 2. Typical values are for TA = 25oC and nominal V DD.
t RC A0 - A7
CHIP-SELECT 1
tDOA1
tDOH1
CHIP-SELECT 2
tDOA2
t DO H2
OUTPUT DISABLE
tDOA3
tDOH3
READ/WRI TE tAA
DATA OUT
HIGH IMPEDANCE
DATA OUT VALID
HIGH IMPEDANCE
FIGURE 1. READ CYCLE TIMING WAVEFORMS
Dynamic Electrical Specifications At TA + -40 to +85oC, VDD ±5%, Input t R, t F = 20ns, VIH = 0.7 VDD, VIL = 0.3 VDD ,
CL = 100 pF. TEST CONDITIONS VDD (V) (NOTE 1) MIN LIMITS CD1822 (NOTE 2) TYP (NOTE 1) MIN CDP1822C (NOTE 2) TYP
PARAMETER Read Cycle Times (Figure 2) Write Cycle tWC
M AX
M AX
UNITS
5 10
500 300 200 110 50 40 250 150
-
-
500 200 50 250 -
-
-
ns ns ns ns ns ns ns ns
A ddress Setup
tAS
5 10
Write Recovery
tWR
5 10
Write Width
tWRW
5 10
14
CDP1822, CDP1822C
Dynamic Electrical Specifications At TA + -40 to +85oC, VDD ±5%, Input t R, t F = 20ns, VIH = 0.7 VDD, VIL = 0.3 VDD ,
CL = 100 pF. (Continued) TEST CONDITIONS VDD (V) tDS 5 10 Data Hold tDH 5 10 Chip-Select 1 Setup tCS1S 5 10 Chip-Select 2 Setup tCS2S 5 10 Chip-Select 1 Hold tCS1H 5 10 Chip-Select 2 Hold tCS2H 5 10 Output Disable Set-Up tODS 5 10 NOTES : 1. Time required by a limit device to allow for indicated function. 2. Typical values are for TA = 25oC and nominal V DD. (NOTE 1) MIN 250 150 50 40 200 110 200 110 0 0 0 0 200 110 LIMITS CD1822 (NOTE 2) TYP (NOTE 1) MIN 250 50 200 200 0 0 0 0 200 CDP1822C (NOTE 2) TYP -
PARAMETER Input Data Setup Time
M AX -
M AX -
UNITS ns ns ns ns ns ns ns ns ns ns ns ns ns ns
15