Radiation Hardened CMOS Dual SPDT Analog Switch
Intersil's Satellite Applications Flow TM (SAF) devices are fully tested and guaranteed to 100kRAD total dose. This QML Class T device is processed to a standard flow intended to meet the cost and shorter lead-time needs of large volume satellite manufacturers, while maintaining a high level of reliability. The HS-390RH-T analog switch is a monolithic device fabricated using Radiation Hardened CMOS technology and the Intersil dielectric isolation process for latch-up free operation. Improved total dose hardness is obtained by layout (thin oxide tabs extending to a channel stop) and processing (hardened gate oxide). These switches offer lowresistance switching performance for analog voltages up to the supply rails. "ON" resistance is low and stays reasonably constant over the full range of operating voltage and current. "ON" resistance also stays reasonably constant when exposed to radiation, being typically 30 pre-rad and 35 post 100kRAD(Si). Break-before-make switching is controlled by 5V digital inputs.
Features
· QM L Class T, Per MIL-PRF-38535 · Radiation Performance - Gamma Dose () 1 x 105 RAD(Si) - No Latch-Up, Dielectrically Isolated Device Islands · Pin for Pin Compatible with Intersil HI-390 Series Analog Switches · Analog Signal Range 15V · Low Leakage . . . . . . . . . . . . . . . . 100nA (Max, Post Rad) · Low rON . . . . . . . . . . . . . . . . . . . . . . 60 (Max, Post Rad) · Low Operating Power. . . . . . . . . . 100µA (Max, Post Rad)
Pinouts
HS1-390RH (SBDIP), CDIP2-T16 TOP VIEW
D1 NC D3 S3 S4 1 2 3 4 5 6 7 8 16 S1 15 IN1 14 V13 GND 12 NC 11 V+ 10 IN2 9 S2
Specifications
Specifications for Rad Hard QML devices are controlled by the Defense Supply Center in Columbus (DSCC). The SMD numbers listed below must be used when ordering. Detailed Electrical Specifications for the HS-390RH-T are contained in SMD 5962-95813. A "hot-link" is provided from our website for downloading. www.intersil.com/spacedefense/newsafclasst.asp Intersil's Quality Management Plan (QM Plan), listing all Class T screening operations, is also available on our website. www.intersil.com/quality/manuals.asp
D4 NC D2
HS9-390RH (FLATPACK), CDFP4-F16 TOP VIEW
D1 NC D3 S3 S4 D4 NC D2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 S1 I N1 VG ND NC V+ I N2 S2
Ordering Information
ORDERING NUMBER 5962R9581303TE C 5962R9581303TY C PART NUMBER HS 1-390RH-T HS 9-390RH-T TEMP. RANGE (oC) -55 to 125 -55 to 125
Functional Diagram
IN N P D
NOTE: Minimum order quantity for -T is 150 units through distribution, or 450 units direct. TRUTH TABLE LOGIC 0 1 SW1 SW2 OFF ON SW3 SW4 ON OFF
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a trademark of Intersil Americas Inc. Copyright © Intersil Americas Inc. 2002. All Rights Reserved Satellite Applications FlowTM (SAF) is a trademark of Intersil Corporation.
HS-390RH-T Die Characteristics
DIE DIMENSIONS: (2130µm x 1930µm x 279µm ±25.4µm) 84 x 76 x 11mils ±1mil METALLIZATION: Type: Al Thickness: 12.5kÅ ±2kÅ SUBSTRATE POTENTIAL: Unbiased (DI) BACKSIDE FINISH: Gold PASSIVATIO N: Type: Silox (SiO2) Thickness: 8.0kÅ ±1.0kÅ WORST CASE CURRENT DENSITY: < 2.0e5 A/cm 2 TRANSISTOR COUNT: 76 PROCESS: Metal Gate CMOS, Dielectric Isolation
Metallization Mask Layout
HS-390R H-T
IN1 D3 D1 S1
S3
VG ND
S4
V+
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation's quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
Sales Office Headquarters
NORTH AMERICA Intersil Corporation 7585 Irvine Center Drive Suite 100 Irvine, CA 92618 TEL: (949) 341-7000 FAX: (949) 341-7123 Intersil Corporation 2401 Palm Bay Rd. Palm Bay, FL 32905 TEL: (321) 724-7000 FAX: (321) 724-7946 EUROPE Intersil Europe Sarl Ave. William Graisse, 3 1006 Lausanne Switzerland TEL: +41 21 6140560 FAX: +41 21 6140579 ASIA Intersil Corporation Unit 1804 18/F Guangdong Water Building 83 Austin Road TST, Kowloon Hong Kong TEL: +852 2723 6339 FAX: +852 2730 1433
2
IN2
D4
D2
S2
|
|