Details, datasheet, quote on part number:NetScan/1500
| |
Datasheet text preview:
ChartScan/1400 & NetScan /1500
®
TM
TM
Voltage and Temperature Recorders
the smart approach to instrumentationTM
ChartScan/1400TM
· Serial-based paperless chart recorder · C o n n e c t s to PC via RS-232/422 interface · Optional IEEE 488 interface available · Capable of stand-alone operation
NetScanTM/1500
· Ethernet-based data logging and control instrument · Interface via 10BASE-T Ethernet or RS-232/422 · Can be controlled remotely via TCP/IP protocol
Common Features
· M e a s u r e isolated temperature, DC volts, AC volts, & waveforms in one compact instrument · Convenient signal connectivity; recessed safety jack, BNC, subminiature plug, or screw-terminal connections · Expandable up to 128 channels · Measure 128 channels in less than one second · Single-channel burst mode for digitizing waveforms at rates up to 20 kHz · 32 alarm outputs & 8 digital inputs · Two programmable scan rates for: - pre- & post-trigger sampling - a c c e l e r a t e d sampling on-event detection · 128 Kreadings of memory, expandable up to 4 Mreadings · Built-in real-time clock: - synchronizes acquisition to time of day - provides time & date stamping for trend monitoring · RS-232 interface standard
NetScan/1500 provides measurement and control via Ethernet and the Internet
The ChartScan/1400 and NetScan/1500 are compact voltage and temperature recorders that can be used as paperless chart recorders or as data logging and control instruments. Their convenient BNC, safety jack, subminiature plug, and screw-terminal connectors make signal connection easier than other data recorders or loggers. Both systems offer high speed, high channel counts, voltage isolation, and user-selectable signal conditioning.
Software (see p. 227) · C h a r t V i e w TM or ChartViewNET TM Out-of-the-BoxTM scrolling strip-chart a p p l i c a t i o n for effortless setup, acquisition, & real-time display · DIAdem®-View for post-acquisition viewing of data files · ScanCalTM calibration software · L a b V I E W ® for Windows ® virtual instrument (VI) example* · CIMScan ® support for distributed applications · S c a n S e r v e r TM support for popular SCADA/HMI applications
ChartScan/1400
The ChartScan/1400 is a next-generation recorder that combines the ease-ofuse common in paper-based strip-chart recorders with the advanced features of PC-based data acquisition systems. The C h a r t S c a n offers distinct advantages over typical chart recorders. For example, it is not prone to mechanical failure like conventional paper-based recorders with chart drives, paper feeds, moving pens, and knobs.
The ChartScan/1400 portable recorder is ideal for making isolated temperature and voltage measurements (notebook PC not included)
* Contact factory for NetScan Ethernet support in LabVIEW
QUICK tel: 440-439-4091 fax: 440-439-4093
FIND sales@iotech.com www.iotech.com
205
Temperature & Voltage Scanning Instruments
ChartScan/1400 & NetScan /1500
®
TM
TM
General Information
the smart approach to instrumentationTM
NetScan/1500's back panel provides an Ethernet and additional RS-232 port Unlike other hybrid recorders--which are often handicapped by difficult menu systems, low-visibility LCD displays, and inconvenient multi-purpose keypads-- the ChartScan/1400 features Windows ®based ChartView software for easy setup, acquisition, and real-time display, right Out-of-the-BoxTM.
ChartView Out-of-the-BoxTM data logging software provides effortless real-time scrolling and data capture to disk
NetScan/1500
Temperature & Voltage Scanning Instruments
Now take measurements and output control signals wherever there is an Ethernet connection. The new NetScan/1500 offers 16 to 128 isolated channels of voltage and direct thermocouple measurements. In addition, 32 digital outputs can be programmed to automatically operate as alarm outputs, or can be indiv i d u a l l y controlled via the network. Eight digital inputs allow the network to read the status of digital signals. Since the NetScan/1500 system uses TCP/IP protocol, users can also communicate w i t h distant NetScan devices via an Internet-accessible Ethernet address. ChartScan/1400 Out-of-the-BoxTM. Optional ChartView PlusTM adds expanded display and recording capabilities. display data from, and control outputs of, m u l t i p l e NetScan devices distributed throughout a network. Custom applications that access thousands of channels from distributed NetScans can easily be created without programming. Optional ScanServerTM software (see p. 240) permits access to any number of NetScans from all popular SCADA/HMI applications, such as those from Wonderware® and Intellution®. ScanServer supports all OPC/ DDE-compliant environments, including Microsoft® Excel.
ChartViewNETTM Software
The NetScan/1500 includes ChartViewNET software (see p. 228), the Ethernet version of IOtech's popular ChartView software. The easy-to-use graphical application allows the NetScan to be accessed from any PC on the network. Accessing one NetScan at a time, ChartViewNET's chart recorderlike interface provides real-time, smoothscrolling waveforms plus logging to disk. It also offers a variety of real-time indicators, such as bar graphs, dials, and digital display. Optional ChartViewNET PlusTM adds expanded display and recording capabilities to ChartViewNET software. For applications that require concurrent access to multiple NetScan devices, use CIMScan or ScanServer software. Optional CIMScan® software (see p. 235) is a low-cost SCADA/HMI application for distributed acquisition and control applications, where a single CIMScan screen can
ChartViewTM Software
The ChartScan/1400 includes ChartView, one of IOtech's Out-of-the-BoxTM, Windowsbased setup and acquisition applications (see p. 228). ChartView provides a graphical spreadsheet-style user interface that lets you easily configure your hardware, a c q u i s i t i o n , and display parameters. ChartView features a no-programming approach that enables data collection and display within minutes of taking the
Common Architecture
The ChartScan/1400 and NetScan/1500 share an advanced architecture that offers an unrivaled low-cost per channel. Both instruments scan at 147 readings/s and can stream data direct-to-disk (your PC's hard drive) in real time. For stand-alone operation, the systems come standard with 128 Kreadings (256 Kbytes) deep m e m o r y that is expandable to 4 Mreadings (8 Mbytes).
QUICK tel: 440-439-4091 fax: 440-439-4093
FIND sales@iotech.com www.iotech.com
206
ChartScan/1400 & NetScan /1500
®
TM
TM
General Information
Feature
Measurement Parameters A/D resolution Accuracy (w/J thermocouple) Thermocouples supported Voltage input Channel-to-channel isolation Channel-to-system isolation Scanning Parameters Switching technology Max scan rate Max single-channel scan rate Min channel configuration Max channel configuration Data Handling Built-in memory Max memory with expansion IEEE 488 interface RS-232 interface Ethernet Time & date stamping Triggering Digital trigger input Analog trigger input Trigger on time of day Pre-trigger scan rate Post-trigger scan rate Digital Inputs Programmable Alarm Outputs Software ChartView ChartView Plus ChartViewNET ChartViewNET Plus LabVIEW CIMScan ScanServer Hardware Options 16-ch isolated TC/voltage scanning module 16-ch isolated low voltage scanning module 16-ch isolated high voltage scanning module 4-slot expansion chassis 16-ch digital output relay card
the smart approach to instrumentationTM
Isolated Inputs
The ChartScan/1400 and NetScan/1500 are ideal for temperature and voltage measurements that require channel-to-channel isolation. The systems provide 500V isolation for high-voltage applications using the CSN14/HV/S module and 200V isolation when the thermocouple and other voltage modules are used. The systems achieve this high isolation by using individual relays on each channel, yet still maintain a very fast 147 channels/s scan rate.
ChartScan/1400
16 bit w/oversampling ±0.5°C J,K,T,E,R,S,B,N ±100 mV to 250V up to 500V 500V mechanical relays 147 channels/s 20 kHz 16 channels 128 channels 128 Kreadings 4 Mreadings optional optional
NetScan/1500
16 bit w/oversampling ±0.5°C J,K,T,E,R,S,B,N ±100 mV to 250V up to 500V 500V mechanical relays 147 channels/s 20 kHz 16 channels 128 channels 128 Kreadings 4 Mreadings optional
Expansion Options
The ChartScan/1400 and NetScan/1500 chassis can accommodate up to four plug-in option modules for a total of 64 channels. For larger systems, the CSN/Exp expansion chassis connects directly to the main unit to allow four additional plug-in modules, expanding the system from 64 to 128 channel capacity. Power is derived directly from the main unit so no additional power supplies or cables are required.
programmable programmable 8 32 included optional -- -- included optional optional
programmable programmable 8 32 included optional included optional -- optional optional
Faster Scanning
The ChartScan/1400 and NetScan/1500 offer faster scanning than a typical stripchart recorder, and exceed the typical two Hz rate found on most strip-chart, multi-point, or hybrid recorders. The units provide an array of scanning capabilities to meet your application requirements. Because data-logging and chart r e c o r d i n g applications frequently require logging at fixed time intervals, the systems use the standard hours-minutesseconds (hh:mm:ss.s) format to specify the time interval between channel scans. Users can configure the unit to begin and end data logging on a specified event such as a TTL signal, temperature level, IEEE GET, alarm condition, absolute time of day, or upon completion of a specified number of readings.
CSN/Exp Expansion Chassis ChartScan/1400 or NetScan/1500
P r o g r a m m a b l e Scan Rates. The ChartScan/1400 and NetScan/1500 offer programmable scan rates for applications requiring acceleration of the measurement rate on a specified event, such as an alarm condition. For example, you
can program the instrument to scan once per minute and then, upon the occurrence of a specified alarm condition, switch to scanning once per second. Upon cessation of the alarm condition, the unit resumes scanning at the rate of once per minute.
QUICK tel: 440-439-4091 fax: 440-439-4093
FIND sales@iotech.com www.iotech.com
207
Temperature & Voltage Scanning Instruments
ChartScan/1400 & NetScan /1500
®
TM
TM
General Information
Typical Expansion Module Block Diagram
Open T/C detection sources Cold-junction compensation sensors Auto zero Ch 1 Isolation relays Gain/sequence decoding µProcessor controller Relay coil decoder/driver Ch 16 Analog Outputs IA PGA to A/D
the smart approach to instrumentationTM
Scanning Techniques
The ChartScan/1400 and NetScan/1500 offer three measuring modes for application flexibility. These include a line-cycle integration mode, a high-speed multichannel scanning mode, and a single-channel burst mode. A discussion of the particular attributes of each measuring mode follows. Line-Cycle Integration. The ability to sample and average 32 measurements per line cycle over multiple line cycles, makes the systems useful for high-accuracy applications and thermocouple measurements in applications subject to high AC noise environments. When engaged in line-cycle averaging, the units provide AC or DC voltage, or linearized and compensated thermocouple-based temperature readings at up to 44 channels/s. The AC voltage measurement capability is ideal for power-line monitoring applications. For each measurement, the unit calculates the equivalent true RMS voltage based on 32 samples it acquires during each AC line cycle.
Line Cycle Integration
Line DC Volts & AC Maximum Cycles Thermocouples Volts Channel per Reading 50 Hz 60 Hz 50 Hz 60 Hz Number 128 1 38.5* 44* 38.5* 44* 22* 128 19.2* -- -- 2 9.6* 128 -- -- 11* 4 8 4.8* 5.5* 122 -- -- * channels/s
Accuracy
The ChartScan/1400 and NetScan/1500 have a number of features and capabilities that enable them to deliver the high accuracy demanded by many research applications. High Resolution. The systems are equipped with a high-speed 16-bit A/D converter. This enables the systems to offer up to 0 . 1 ° C and 3.05 µ V resolution with the CSN14/TC/P thermocouple/volt scanning module. Noise Filtering. The systems reduce noise by sampling and averaging 32 measurements per line cycle. The systems also offer the flexibility to average across multiples of 1, 2, 4, or 8 line cycles. High-Accuracy Cold Junction Compensation. The systems' CSN14/TC/P thermocouple/volt scanning module features multiple, strategically-located temperature sensors that provide high-accuracy, cold-junction compensation across all inputs. Accurate Linearization. The systems enable quick and accurate linearization by providing built-in lookup tables for popular thermocouple types, including J, K, T, E, R, S, B, and N.
Temperature & Voltage Scanning Instruments
High-Speed Multichannel Scanning. When line-cycle averaging is disabled, the systems can average 1, 2, 4, 8, or 16 samples per channel. When the units are configured to take 1 sample per channel, they can scan 147 channels/s or all 128 channels in under one second. This is important when trying to timecorrelate a large number of channels. By contrast, data loggers and other temperature measuring instruments typically acquire readings at only 5 to 20 channels/s. Single-Channel Burst Mode. In single-channel burst mode, the systems can sample at up to 20 kHz on a single channel and store the data in memory, which can be expanded up to 4 Mreadings. When performing post-acquisition waveform analysis such as Fast Fourier Transforms (FFTs), the units can return each data point in a waveform to your program. Alternatively, the units can provide a true RMS value of the sampled voltage.
QUICK tel: 440-439-4091 fax: 440-439-4093
FIND sales@iotech.com www.iotech.com
208
ChartScan/1400 & NetScan /1500
®
TM
TM
General Information
CSN/Relay Card Block Diagram
2-coil latch relay Alarm 1 Pulse circuit Buffer Disconnectable terminal block 2-coil latch relay Alarm 8 Pulse circuit Buffer 2-coil latch relay Alarm 9 Pulse circuit Buffer Disconnectable terminal block 2-coil latch relay Alarm 16 Pulse circuit Buffer Set Reset Set Reset Set Reset Set Reset
the smart approach to instrumentationTM
Alarms
Detecting an alarm condition is a common requirement in logging applications and the ChartScan/1400 and NetScan/1500 offer a number of modes to facilitate alarm detection. With 32 digital TTL alarm outputs available on the 50-pin rear panel connector or 16 outputs via the high-current capacity CSN/Relay option*, multiple conditions can be set and monitored. Unlike some instruments which allow only one channel to be assigned to a single alarm output, the ChartScan/1400 or NetScan/1500 allow one or more channels to be logically "OR-ed" and connected to an alarm output. In this way, all 128 channels can participate in the alarm process. Channel settings for alarm limit and hysteresis are individually set with the alarm output remaining high for as long as the alarm condition is valid.
Edge connector
CSN/Relay card supports 16 high-current alarm outputs The units' ability to automatically update alarm outputs in real time affords you greater control of your applications and reduces your programming burden by eliminating t h e need for constant per-channel monitoring by the controlling computer. In addition, the units can update alarmed output channels in real time, at their programmed scan rates, and can alert the host computer of active alarm conditions via an IEEE 488 service request (SRQ).
Memory
F o r high-speed and long-term data logging, the systems are equipped with 128 Kreadings of data storage, which can be field expanded to 4 Mreadings. Since each application requires different measurements, the units make each channel's high, low, and last readings available throughout acquisition.
NetScan Communication
Connecting a Local Area Network (LAN) or Wide Area Network (WAN) to the NetScan/1500 is simple via the standard 10BASE-T Ethernet interface. This allows any PC on the network to access the NetScan. In addition, a second port is available for RS-232/422 communication with a local PC. A serial-based device may be attached to this port and accessed through the NetScan/1500**. Internet. If the LAN or WAN has a gateway to the Internet, then a network PC can c o m m u n i c a t e with remotely located NetScans via TCP/IP protocol.
Real-Time Clock
The ChartScan/1400 and NetScan/1500 feature a real-time clock that allows you to synchronize acquisition to a specific time of day. During acquisition, the system stores the time and date of every data scan in
ChartScan Communication
C o n n e c t i n g your computer to the ChartScan/1400 is simple via the standard RS-232/422 interface. In addition, an optional IEEE 488 interface can be added via a simple plug-in module. ChartScan supports any Hayes-compatible modem.
* CSN/Relay Card occupies one slot in the mainframe reducing total channels to 48, expandable to 112 ** This feature is not supported by ChartViewNET
QUICK tel: 440-439-4091 fax: 440-439-4093
FIND sales@iotech.com www.iotech.com
209
Temperature & Voltage Scanning Instruments
memory, enabling later retrieval of this information for use in plotting and analyzing measurements. The instrument also time and date stamps each channel's high and low excursions, providing a precise time record of a channel's minimum and maximum values.
IEEE 488. The CSN/COM/488 option fully supports the IEEE 488.2 standard and can transfer data up to 300 Kbytes/s. This interface plugs directly into the communications port on the back of the unit and lets you set up, control, and log data from the instrument directly to the computer. IEEE 488 is most commonly used in multii n s t r u m e n t applications where one computer is used with many instruments.
|
|