Details, datasheet, quote on part number:MD-113PIN
| |
Datasheet text preview:
High Performance Double-Balanced Mixer, 5 - 1000 MHz
V 3.00
MD-113
Features
Low Cost Flatpack Conversion Loss: 7 dB Typical Impedance: 50 Ohms Nominal Maximum Input Power: 300 mW max. @ 25°C, Derated linearly to 85°C @ 3.2 mW/°C n IF Port Current: 50 mA Max. n MIL-STD-883 Screening Available
n n n n
FP-2
Description
Transformers convert the LO and RF paths to balanced lines connecting to a low barrier, Schottky diode ring quad. These transformers help provide excellent isolation between ports. Conversion Loss is low. The direct connection of the IF port to the diode quad allows these mixers to be used as phase detectors and bi-phase modulators.
Pin Configuration
Pin No. 1 2 3 4 Function GND GND GND IF Pin No. 5 6 7 8 Function LO GND GND RF
Electrical Specifications1: TA = -55°C to +85°C
Parameter Frequency Range Conversion Loss Test Conditions RF, LO Ports IF Port Frequency 5 - 1000 DC - 1000 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz LO to RF 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz 5 - 50 MHz 50 - 500 MHz 500 - 1000 MHz -- Units MHz MHz dB dB dB dB dB dB dB dB dB dB dB dB -- mV 1 dB Compression 1 dB Desensitization dBm dBm Min -- -- -- -- -- 35 30 25 30 25 20 25 20 15 -- -- -- -- Typ -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- <2 0 -2 Max -- -- 7.5 7.5 8.0 -- -- -- -- -- -- -- -- -- -- -- -- --
Isolation
LO to IF
RF to IF
DC Polarity DC Offset RF Input
Negative
1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
High Performance Double-Balanced Mixer, 5 - 1000 MHz Electrical Specifications: TA = -55°C to +85°C
Parameter SSB Noise Figure Typical Two Tone IM Ratio Test Conditions Within 1 dB of Conversion Loss Max. With 10 dBm input, each input 25 MHz and 35 MHz IF Frequency -- 100 - 550 MHz 550 - 800 MHz 800 - 1000 MHz Units -- dB dB dB Min -- -- -- -- Typ -- >47 >38 >44
MD-113
V 3.00
Max -- -- -- --
Typical Performance Curves
Conversion Loss (RF = -5 dBm, LO = +7 dBm)
8
50
Isolation
LO - RF LO - IF RF - IF
Conversion Loss (dB)
Isolation (dB)
5 10 20 50 100 200 500 1000
40
7
30
6
20 5 10 20 50 100 200 500 1000
Frequency (MHz)
Frequency (MHz)
Conversion Loss vs. LO Power (LO = 1.060 GHz, RF = 1.000 GHz @ -10 dBm)
10
Ordering Information
Part Number MD-113 PIN Package FP-2
9
Loss (dB)
8
7
6 0 5 10 15 20
LO Power (dBm)
Specifications subject to change without notice. n North America: Tel. (800) 366-2266 n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298 n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.