Details, datasheet, quote on part number:RA356
| |
| Part: | RA356 |
| Category: | Discrete => Diodes & Rectifiers => Standard Recovery Rectifiers |
| Description: | Package Type : RA, if : 35A, VRM : 800V |
| Company: | Micro Commercial Components |
| Datasheet: | Download RA356 datasheet File size : 262 kB |
| Request For quote: | Find where to buy RA356
|
| |
Datasheet text preview:
MCC
Features
· · · · · Low Cost Low Leakage Low Forward Voltage Drop High Current Capability For Automotive Applications
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
RA351 THRU RA357
35Amp Recover Rectifier 50 to 1000 Volts
RA
A
· ·
Maximum Ratings
Operating Temperature: -55°C to +175°C Storage Temperature: -55°C to +175°C
MCC Catalog Number RA351 RA352 RA353 RA354 RA355 RA356 RA357
Device Marking
---------------
Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V
Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V
Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
D
E C
B
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward I F(AV) 35A TA = 150°C Current Peak Forward Surge IFSM 500A 8.3ms, half sine Current Maximum 1.0V IFM = 35A; Instantaneous VF Forward Voltage TJ = 25°C* Maximum DC Reverse Current At IR 5.0 µA TJ = 25°C Rated DC Blocking 150µA TJ = 1 00 °C Voltage Typical Junction CJ 100pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse test: Pulse width 300 µsec, Duty cycle 2%
DIMENSIONS DIM A B C D E INCHES MIN .380 .165 .215 .234 ---MAX .410 .185 .220 .250 5' MM MIN 9.70 4.20 5.50 6.00 --MAX 10.40 4.70 5.70 6.40 5' NOTE
Revision: 3
www.mccsemi.com
2003/04/30
RA351 thru RA357
Figure 1 Typical Forward Characteristics 20 100 60 40 25 20 25°C Amps 10 .6 .4 .2 .1 .06 .04 .02 .01 .4 .6 .8 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 400 300 200 Amps 100 50 0 1 2 8 10 1.0 1.2 1.4 15 10 Amps 20 30 35 Figure 2 Forward Derating Curve
MCC
Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 125 150 175
0
°C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C Figure 4 Peak Forward Surge Current 500
4
6
20
Cycles
40 00
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Figure 3 Junction Capacitance
100 60 40 20 pF 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 1000 TJ=25°C
Junction Capacitance - pFversus Reverse Voltage - Volts
Revision: 3
www.mccsemi.com
2003/04/30
|
|