Part:RS1001
Category:Discrete => Bridges => Bridge Rectifiers
Description:Package Type : RS-6, if : 10A, VRM : 50V
Company:Micro Commercial Components
Datasheet:Download RS1001 datasheet   File size : 302 kB
Request For quote:  Find where to buy RS1001
 



Datasheet text preview:
MCC
Features
· · · · Low Leakage Low Forward Voltage Any Mounting Position Silver Plated Copper Leads
RS1001
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
THRU RS1007
10 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
RS-6
A D
Maximum Ratings
· · Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Microsemi Catalog Number RS1001 RS1002 RS1003 RS1004 RS1005 RS1006 RS1007 Device Marking RS1001 RS1002 RS1003 RS1004 RS1005 RS1006 RS1007 Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000v
E B C
-
A
+
G
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element I F(AV) IFSM VF 10 A 300A 1.1V TJ = 65°C 8.3ms, half sine IFM = 5.0A; TJ = 25°C*
DIM A B C D E F G H J K L K
F
H
J
L DIMENSIONS INCHES MIN ------.15 x ----1.00 --------MM MIN ------3.8 x ----25.40 ---------
Maximum DC Reverse Current At IR 10µA TJ = 25°C Rated DC Blocking 100mA TJ = 100°C Voltage *Pulse test: Pulse width 300 µsec, Duty cycle 1%
MAX .925 .763 .680 .23L .300 .157 --.050 .280 .075 .200
MAX 23.50 19.40 17.20 5.57L 7.50 4.00 --1.30 7.00 1.90 5.10
NOTE
NOM HOLE NOM NOM TYP NOM 3PL
Revision: 3
www.mccsemi.com
2003/04/30
RS1001 thru RS1007
Figure 1 Typical Forward Characteristics 100 60 40 20 10 6 4 2 Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 .8 1.0 1.2 1.3 25° C 10 6 4 2 1 .6 .4 .2 µ Amps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 40 60 80 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts 100 120 140 TJ=25°C TJ=100°C Figure 2 Typical Reverse Characteristics
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 12
Figure 4 Peak Forward Surge Current 300
10
250 200 150 Amps 100 50
8
Amps
6 4 2
Single Phase, Half Wave 60Hz Resistive or Inductive Load 20 40 60 80 °C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 100 120 140
0
1
2
4
6
8 10 Cycles
20
0
40 00
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
Revision: 3
www.mccsemi.com