Details, datasheet, quote on part number:RS607
| |
| Part: | RS607 |
| Category: | Discrete => Bridges => Bridge Rectifiers |
| Description: | Package Type : RS-6, if : 6.0A, VRM : 1000V |
| Company: | Micro Commercial Components |
| Datasheet: | Download RS607 datasheet File size : 313 kB |
| Request For quote: | Find where to buy RS607
|
| |
Datasheet text preview:
MCC
Features
· · · · ·
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
RS601 THRU RS607
6 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
RS-6
A D
Low Leakage Low Forward Voltage Any Mounting Position Silver Plated Copper Leads Surge Overload Rating Of 200 Amps
Maximum Ratings
· · Operating Temperature: -55°C to +125°C Storage Temperature: -55°C to +150°C Microsemi Catalog Number RS601 RS602 RS603 RS604 RS605 RS606 RS607 Device Marking RS601 RS602 RS603 RS604 RS605 RS606 RS607 Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000v Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000v
B
C
-
A
+
E
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element I F(AV) IFSM VF 6.0A 200A 1.1V TA = 65°C 8.3ms, half sine
I H DIMENSIONS INCHES MIN .895 --.660 .15 x 1.00 .048 .260 .180 .185 MM MIN 22.70 --16.80 3.8 x 25.40 1.20 6.60 4.60 4.70
F
G
IFM = 3.0A; TJ = 25°C
DIM A B C D E F G H I
Maximum DC Reverse Current At IR 10µA TA = 25°C Rated DC Blocking 1 mA TA = 100°C Voltage *Pulse test: Pulse width 300 µsec, Duty cycle 1%
MAX .935 .760 .700 .23L --.052 .280 .220 .205
MAX 23.70 19.30 17.80 5.57L --1.30 7.10 5.60 5.20
NOTE
HOLE TYP
Revision: 3
www.mccsemi.com
2003/04/30
RS601 thru RS607
Figure 1 Typical Forward Characteristics 100 60 40 20 10 6 4 2 Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 .8 1.0 1.2 1. 25° C 10 6 4 2 1 .6 .4 .2 µ Amps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 40 60 80 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts 100 120 140 TA=25°C TA=100°C Figure 2 Typical Reverse Characteristics
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 12
Figure 4 Peak Forward Surge Current 250
10
200 150 100 Amps 50 25
8
Amps
6 4 2
Single Phase, Half Wave 60Hz Resistive or Inductive Load 20 40 60 80 °C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 100 120 140
0
1
2
4
6
8 10 Cycles
20
0
40 00
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
Revision: 3
www.mccsemi.com
2003/04/30
|
|