Digchip : Database on electronics components
Electronic components database
Search:                      In section:
Member, Distributor  
Log In
Email:
Password:

Details, datasheet, quote on part number:DB101
 
 
Part:DB101
Category:Discrete => Diodes & Rectifiers => General Purpose Diodes
Description:1 Amp Single Phase Glass Passivated Bridge Rectifier 50 to 1000v
Company:Microsemi Corporation
Datasheet:Download DB101 datasheet   File size : 119 kB
Request For quote:  Find where to buy DB101
 



Datasheet text preview:
21201 Itasca St. Chatsworth, CA 91311 Phone: (818) 701-4933 Fax: (818) 701-4939

DB101 THRU DB107
1 Amp Single Phase Glass Passivated Bridge Rectifier 50 to 1000 Volts
DB-1
Notch

Features
· · · · Through Hole Package Glass Passivated Diode Construction Moisture Resistant Epoxy Case High Surge Current Capability

Maximum Ratings
· · Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V

Microsemi Part Number DB101 DB102 DB103 DB104 DB105 DB106 DB107

Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V

B

~
A

+

C

~

E F G D

H

Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward IF(AV) 1A TA = 40°C Current Peak Forward Surge IFSM 50A 8.3ms, half sine Current Maximum 1.1V IFM = 1.0A; Instantaneous VF Forward Voltage TA = 25°C Maximum DC Reverse Current At IR 10µA TA = 25°C Rated DC Blocking 0.5mA TA = 125°C Voltage Typical Junction CJ 25pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
DIMENSIONS INCHES MIN .3 1 5 .2 4 5 .3 0 0 .1 5 5 .1 1 5 ----.1 9 5 MM MIN 8.00 6.20 7.60 3.90 2.90 ----5.00

DIM A B C D E F G H

MAX .335 .255 .350 .165 .135 .060 .020 .205

MAX 8.51 6.60 8.90 4.20 3.40 1.50 .50 5.20

NOTE

DB101 thru DB107
Figure 1 Typical Forward Characteristics 20 10 6 4 2 25°C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .4 .6 .8 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts 1.0 1.2 1.4 20 10 6 4 2 µAmps 1 .6 .4 .2 .1 .06 .04 .02 .01 20 40 60 80 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve 1.2 60 1.0 50 40 30 .6 Amps .4 Amps 20 10 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 °C Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 125 150 175 1 2 4 6 8 10 20 Cycles Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles 40 60 80 100 100 120 140 TA=25°C 100 60 40 Figure 2 Typical Reverse Characteristics

Figure 4 Peak Forward Surge Current

.8

.2

0