54AC191 Up/Down Counter with Preset and Ripple Clock
July 1998
54AC191 Up/Down Counter with Preset and Ripple Clock
General Description
The 'AC191 is a reversible modulo 16 binary counter. It features synchronous counting and asynchronous presetting. The preset feature allows the 'AC191 to be used in programmable dividers. The Count Enable input, the Terminal Count output and the Ripple Clock output make possible a variety of methods of implementing multistage counters. In the counting modes, state changes are initiated by the rising edge of the clock.
Features
n n n n n n n ICC reduced by 50% High speed -- 133 MHz typical count frequency Synchronous counting Asynchronous parallel load Cascadable Outputs source/sink 24 mA Standard Military Drawing (SMD) -- 'AC191: 5962-89749
Logic Symbols
Connection Diagrams
Pin Assignment for DIP and Flatpack
DS100279-1
IEEE/IEC
DS100279-3
Pin Assignment for LCC
DS100279-2
Pin Names CE CP P0 P3 PL U/D Q0 Q3 RC TC
Description Count Enable Input Clock Pulse Input Parallel Data Inputs Asynchronous Parallel Load Input Up/Down Count Control Input Flip-Flop Outputs Ripple Clock Output Terminal Count Output
DS100279-4
FACTTM is a trademark of Fairchild Semiconductor Corporation.
© 1998 National Semiconductor Corporation
DS100279
www.national.com
Functional Description
The 'AC191 is a synchronous up/down counter. The 'AC191 is organized as a 4-bit binary counter. It contains four edge-triggered flip-flops with internal gating and steering logic to provide individual preset, count-up and count-down operations. Each circuit has an asynchronous parallel load capability permitting the counter to be preset to any desired number. When the Parallel Load (PL) input is LOW, information present on the Parallel Load inputs (P0 P3) is loaded into the counter and appears on the Q outputs. This operation overrides the counting functions, as indicated in the Mode Select Table. A HIGH signal on the CE input inhibits counting. When CE is LOW, internal state changes are initiated synchronously by the LOW-to-HIGH transition of the clock input. The direction of counting is determined by the U/D input signal, as indicated in the Mode Select Table. CE and U/D can be changed with the clock in either state, provided only that the recommended setup and hold times are observed. Two types of outputs are provided as overflow/underflow indicators. The terminal count (TC) output is normally LOW. It goes HIGH when the circuits reach zero in the count down mode or 15 in the count up mode. The TC output will then remain HIGH until a state change occurs, whether by counting or presetting or until U/D is changed. The TC output should not be used as a clock signal because it is subject to decoding spikes. The TC signal is also used internally to enable the Ripple Clock (RC) output. The RC output is normally HIGH. When CE is LOW and TC is HIGH, RC output wil go LOW when the clock next goes LOW and will stay LOW until the clock goes HIGH again. This feature simplifies the design of multistage counters, as indicated in Figure 1 and Figure 2. In Figure 1, each RC output is used as the clock input for the next higher stage. This configuration is particularly advantageous when the clock source has a limited drive capability, since it drives only the first stage. To prevent counting in all stages it is only necessary to inhibit the first stage, since a HIGH signal on CE inhibits the RC output pulse, as indicated in the RC Truth Table. A disadvantage of this configuration, in some applications, is the timing skew between state changes in the first and last stages. This represents the cumulative delay of the clock as it ripples through the preceding stages. A method of causing state changes to occur simultaneously in all stages is shown in Figure 2. All clock inputs are driven in parallel and the RC outputs propagate the carry/borrow signals in ripple fashion. In this configuration the LOW state duration of the clock must be long enough to allow the negative-going edge of the carry/borrow signal to ripple through to the last stage before the clock goes HIGH. There is no such restriction on the HIGH state duration of the clock, since the RC output of any device goes HIGH shortly after its CP input goes HIGH. The configuration shown in Figure 3 avoids ripple delays and their associated restrictions. The CE input for a given stage is formed by combining the TC signals from all the preceding stages. Note that in order to inhibit counting an enable signal must be included in each carry gate. The simple inhibit scheme of Figure 1 and Figure 2 doesn't apply, because the TC output of a given stage is not affected by its own CE.
Mode Select Table
Inputs PL H H L H CE L L X H U/D L H X X CP
N N
Mode Count Up Count Down Preset (Asyn.) No Change (Hold)
X X
RC Truth Table
Inputs PL H H H L CE L H X X TC* H X L X CP
J
Outputs RC
J
X X X
H H H
*TC is generated internally H = HIGH Voltage Level L = LOW Voltage Level X = Immaterial N = LOW-to-HIGH Transition
www.national.com
2
Functional Description
(Continued)
DS100279-7
FIGURE 1. N-Stage Counter Using Ripple Clock
DS100279-8
FIGURE 2. Synchronous N-Stage Counter Using Ripple Carry/Borrow
DS100279-9
FIGURE 3. Synchronous N-Stage Counter with Parallel Gated Carry/Borrow
3