Datasheet text preview:
54AC161 · 54ACT161 Synchronous Presettable Binary Counter

November 1998

54AC161 · 54ACT161 Synchronous Presettable Binary Counter
General Description
The 'AC/'ACT161 are high-speed synchronous modulo-16 binary counters. They are synchronously presettable for application in programmable dividers and have two types of Count Enable inputs plus a Terminal Count output for versatility in forming synchronous multistage counters. The 'AC/ 'ACT161 has an asynchronous Master Reset input that overrides all other inputs and forces the outputs LOW. n n n n n n Synchronous counting and loading High-speed synchronous expansion Typical count rate of 125 MHz Outputs source/sink 24 mA 'ACT161 has TTL-compatible inputs Standard Microcircuit Drawing (SMD) -- 'AC161: 5962-89561 -- 'ACT161: 5962-91722

Features
n ICC reduced by 50%

Logic Symbols

Pin Names CEP CET CP MR P0­ P3 PE Q0­ Q3 TC
DS100274-1

Description Count Enable Parallel Input Count Enable Trickle Input Clock Pulse Input Asynchronous Master Reset Input Parallel Data Inputs Parallel Enable Inputs Flip-Flop Outputs Terminal Count Output

IEEE/IEC

DS100274-2

TRI-STATE ® is a registered trademark of National Semiconductor Corporation. FACTTM is a trademark of Fairchild Semiconductor Corporation.

© 1998 National Semiconductor Corporation

DS100274

www.national.com

Connection Diagrams
Pin Assignment for DIP and Flatpak

The Terminal Count (TC) output is HIGH when CET is HIGH and counter is in state 15. To implement synchronous multistage counters, the TC outputs can be used with the CEP and CET inputs in two different ways.

DS100274-3

Pin Assignment for LCC

Figure 1 shows the connections for simple ripple carry, in which the clock period must be longer than the CP to TC delay of the first stage, plus the cumulative CET to TC delays of the intermediate stages, plus the CET to CP setup time of the last stage. This total delay plus setup time sets the upper limit on clock frequency. For faster clock rates, the carry lookahead connections shown in Figure 2 are recommended. In this scheme the ripple delay through the intermediate stages commences with the same clock that causes the first stage to tick over from max to min in the Up mode, or min to max in the Down mode, to start its final cycle. Since this final cycle requires 16 clocks to complete, there is plenty of time for the ripple to progress through the intermediate stages. The critical timing that limits the clock period is the CP to TC delay of the first stage plus the CEP to CP setup time of the last stage. The TC output is subject to decoding spikes due to internal race conditions and is therefore not recommended for use as a clock or asynchronous reset for flip-flops, registers or counters. Logic Equations: Count Enable = CEP · CET · PE TC = Q0 · Q1 · Q2 · Q3 · CET

Mode Select Table
PE X L
DS100274-4

CET X X H L X

CEP X X H X L

Action on the Rising Clock Edge (N) Reset (Clear) Load (PnQn) Count (Increment) No Change (Hold) No Change (Hold)

H H H

Functional Description
The 'AC/'ACT161 count in modulo-16 binary sequence. From state 15 (HHHH) they increment to state 0 (LLLL). The clock inputs of all flip-flops are driven in parallel through a clock buffer. Thus all changes of the Q outputs (except due to Master Reset of the '161) occur as a result of, and synchronous with, the LOW-to-HIGH transition of the CP input signal. The circuits have four fundamental modes of operation, in order of precedence: asynchronous reset, parallel load, count-up and hold. Five control inputs -- Master Reset, Parallel Enable (PE), Count Enable Parallel (CEP) and Count Enable Trickle (CET) -- determine the mode of operation, as shown in the Mode Select Table. A LOW signal on MR overrides all other inputs and asynchronously forces all outputs LOW. A LOW signal on PE overrides counting and allows information on the Parallel Data (Pn) inputs to be loaded into the flip-flops on the next rising edge of CP. With PE and MR HIGH, CEP and CET permit counting when both are HIGH. Conversely, a LOW signal on either CEP or CET inhibits counting. The 'AC/'ACT161 use D-type edge-triggered flip-flops and changing the PE, CEP and CET inputs when the CP is in either state does not cause errors, provided that the recommended setup and hold times, with respect to the rising edge of CP, are observed.

H = HIGH Voltage Level L = LOW Voltage Level X = Immaterial

State Diagram

DS100274-5

www.national.com

2

State Diagram

(Continued)

DS100274-8

FIGURE 1. Multistage Counter with Ripple Carry

DS100274-9

FIGURE 2. Multistage Counter with Lookahead Carry

3

www.national.com

www.national.com
DS100274-6

Block Diagram

4

Please note that this diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays.

Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage (VCC) DC Input Diode Current (IIK) VI = -0.5V VI = VCC + 0.5V DC Input Voltage (VI) DC Output Diode Current (IOK) VO = -0.5V VO = VCC + 0.5V DC Output Voltage (VO) DC Output Source or Sink Current (IO) DC VCC or Ground Current per Output Pin (ICC or IGND) Storage Temperature (TSTG) Junction Temperature (TJ) CDIP -0.5V to +7.0V -20 mA +20 mA -0.5V to VCC + 0.5V -20 mA +20 mA -0.5V to VCC + 0.5V

Recommended Operating Conditions
Supply Voltage (VCC) 'AC 'ACT Input Voltage (VI) Output Voltage (VO) Operating Temperature (TA) 54AC/ACT Minimum Input Edge Rate (V/t) 'AC Devices VIN from 30% to 70% of VCC VCC @ 3.3V, 4.5V, 5.5V Minimum Input Edge Rate (V/t) 'ACT Devices VIN from 0.8V to 2.0V VCC @ 4.5V, 5.5V 2.0V to 6.0V 4.5V to 5.5V 0V to VCC 0V to VCC -55°C to +125°C

125 mV/ns

± 50 mA ± 50 mA -65°C to +150°C
175°C

125 mV/ns

Note 1: Absolute maximum ratings are those values beyond which damage to the device may occur. The databook specifications should be met, without exception, to ensure that the system design is reliable over its power supply, temperature, and output/input loading variables. National does not recommend operation of FACTTM circuits outside databook specifications.

DC Characteristics for 'AC Family Devices
Symbol Parameter VCC (V) VIH Minimum High Level Input Voltage VIL Maximum Low Level Input Voltage VOH Minimum High Level Output Voltage 3.0 4.5 5.5 3.0 4.5 5.5 3.0 4.5 5.5 54AC TA = -55°C to +125°C Guaranteed Limits 2.1 3.15 3.85 0.9 1.35 1.65 2.9 4.4 5.4 (Note 2) VIN = VIL or VIH 3.0 4.5 5.5 VOL Maximum Low Level Output Voltage 3.0 4.5 5.5 2.4 3.7 4.7 0.1 0.1 0.1 (Note 2) VIN = VIL or VIH 3.0 4.5 5.5 IIN IOLD IOHD ICC Maximum Input Leakage Current Minimum Dynamic Output Current (Note 3) Maximum Quiescent 5.5 5.5 5.5
5

Units

Conditions

VOUT = 0.1V V or VCC - 0.1V VOUT = 0.1V V or VCC - 0.1V IOUT = -50 µA V

IOH = -12 mA V IOH = -24 mA IOH = -24 mA IOUT = 50 µA V

0.5 0.5 0.5 V µA mA mA µA

IOL = 12 mA IOL = 24 mA IOL = 24 mA VI = VCC, GND VOLD = 1.65V Max VOHD = 3.85V Min VIN = VCC
www.national.com

5.5

± 1.0
50 -50 160