Part: E2E-X2MF2-M1
Category: Sensors -> Proximity Sensors
Description: E2E 3-Wire DC Short Barrel Inductive Proximity Sensordata Sheet
Company: Omron Corporation
Datasheet: Download E2E-X2MF2-M1 datasheet File size : 59 kB
Request For quote: Find where to buy E2E-X2MF2-M1
Datasheet text preview:
R
Short Barrel Inductive Prox
Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench
flats for easy installation H Solid potted internal circuitry withstands shocks and water washdown to IP67 H High visibility indicator H Miniature and standard sizes
E2E 3 -WIRE DC
Ordering Information
J PREWIRED MINIATURE SENSORS
Type Shielded Size 4 mm dia. M5 5.4 mm dia. Sensing distance Output configuration N PN PNP N PN PNP N PN PNP Part number NO E2E -CR8C1 E2E -CR8B1 E2E-X1C1 E2E-X1B1 E2E -C1C1 E2E -C1B1 NC E2E -CR8C2 E2E -CR8B2 E2E-X1C2 E2E-X1B2 E2E -C1C2 E2E -C1B2
.8 mm 0 1 mm 1 mm
J PREWIRED SHIELDED STANDARD SENSORS
Type Shielded Shielded Size M8 M12 M18 M30 Sensing distance Output configuration N PN PNP N PN PNP N PN PNP N PN PNP Part number NO E2E-X1R5E1 E2E-X1R5F1 E2E-X2E1 E2E-X2F1 E2E-X5E1 E2E-X5F1 E2E-X10E1 E2E-X10F1 NC E2E-X1R5E2 E2E-X1R5F2 E2E-X2E2 E2E-X2F2 E2E-X5E2 E2E-X5F2 E2E-X10E2 E2E-X10F2
.5 mm 1 2 mm 5 mm 10 10 mm
Note: 1. A different oscillating frequency is available. Add a "5" to the part number (e.g., E2E-X5E15). 2. E2E sensors with robotic cable are available. Add a "-R" in the part number (e.g., E2E-X5E1-R).
2
E2E 3 -Wire DC
J PREWIRED UNSHIELDED STANDARD SENSORS
Type Unshielded Size M8 M12 M18 M30 18 mm Sensing distance 2 mm Output configuration N PN PNP N PN PNP N PN PNP N PN PNP Part number NO E2E-X2ME1 E2E-X2MF1 E2E-X5ME1 E2E-X5MF1 E2E-X10ME1 E2E-X10MF1 E2E-X18ME1 E2E-X18MF1 NC
E2E 3 -Wire DC
E2E-X2ME2 E2E-X2MF2 E2E-X5ME2 E2E-X5MF2 E2E-X10ME2 E2E-X10MF2 E2E-X18ME2 E2E-X18MF2
5 mm 10 10 mm
Note: 1. A different oscillating frequency is available. Add a "5" to the part number (e.g., E2E-X5E15). 2. E2E sensors with robotic cable are available. Add a "-R" in the part number (e.g., E2E-X5E1-R).
J SENSORS WITH BUILT-IN M12 MICROCHANGER CONNECTOR
Type Shielded Size M8 M12 M18 M30 Unshielded M8 M12 M18 M30 18 mm Sensing distance Output configuration N PN PNP N PN PNP N PN PNP N PN PNP N PN PNP N PN PNP N PN PNP N PN PNP Part number NO E2E-X1R5E1-M1 E2E-X1R5F1-M1 E2E-X2E1-M1 E2E-X2F1-M1 E2E-X5E1-M1 E2E-X5F1-M1 E2E-X10E1-M1 E2E-X10F1-M1 E2E-X2ME1-M1 E2E-X2MF1-M1 E2E-X5ME1-M1 E2E-X5MF1-M1 E2E-X10ME1-M1 E2E-X10MF1-M1 E2E-X18ME1-M1 E2E-X18MF1-M1 NC E2E-X1R5E2-M1 E2E-X1R5F2-M1 E2E-X2E2-M1 E2E-X2F2-M1 E2E-X5E2-M1 E2E-X5F2-M1 E2E-X10E2-M1 E2E-X10F2-M1 E2E-X2ME2-M1 E2E-X2MF2-M1 E2E-X5ME2-M1 E2E-X5MF2-M1 E2E-X10ME2-M1 E2E-X10MF2-M1 E2E-X18ME2-M1 E2E-X18MF2-M1
.5 mm 1 2 mm 5 mm 10 10 mm 2 mm 5 mm 10 10 mm
Note: Connector cordsets: For MicroChangeR models, use OMRON Y96E-4jDj.
J SENSORS WITH BUILT-IN M8 NANOCHANGER CONNECTOR
Type Shielded Size M8 Sensing distance Output configuration N PN PNP Unshielded M8 2 mm N PN PNP Part number NO E2E-X1R5E1-M3 E2E -X1R5F1-M3 E2E-X2ME1-M3 E2E-X2MF1-M3 NC E2E-X1R5E2-M3 E2E -X1R5F2-M3 E2E-X2ME2-M3 E2E-X2MF2-M3
.5 mm 1
Note: Connector cordsets: For NanoChangeR models, use OMRON X3SF-M42j-40j-R or Brad Harrison equivalent.
3
E2E 3 -Wire DC
J ACCESSORIES
Description Mounting brackets Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Silicone rubber covers for shielded sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Part number Y92E-B8 Y92E-B12 Y92E-B18 Y92E-B30 Y92E-E12-2 Y92E-E18-2 Y92E-E30-2
E2E 3 -Wire DC
J REPLACEMENT PARTS
Description Mounting hardware including one pair of metal nuts and one washer Fits M5 size sensors Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Part number M5-MHWS M8-MHWS M12-MHWS M18-MHWS M30-MHWS
4
E2E 3 -Wire DC
E2E 3 -Wire DC
Spec ific ations
J MINIATURE SENSORS
Part number Size Type Sensing distance Supply voltage Current consumption Sensing object Setting distance Standard object (mild steel, L x W x H) Differential travel Response frequency Control output Operation E2E-CR8jj 4 mm (0.16 in) dia. Shielded 0.8 mm (0.03 in) ± 15% 17 mA max. Magnetic metals 0 to 0.5 mm (0 to 0.02 in) 5 x 5 x 1 mm (0.2 x 0.2 x 0.04 in) 15% max. of effective distance 3 k Hz C1 models: C2 models: B1 models: B1 models: 2 VDC NPN-NO open collector NPN-NC open collector PNP-NO open collector PNP-NC open collector 0 to 7 mm (0 to 0.03 in) 8 x 8 x 1 mm (0.3 x 0.3 x 0.04 in) 1 mm (0.04 in) ± 15% 10 to 30 VDC, 10% max. permissible ripple peak to peak E2E-X1jj M5 E2E-C1jj 5.5 mm (0.21 in) dia.
Max. load Max. on-state voltage drop Circuit protection Indicators Ambient temperature Ambient humidity Operating Operating
100 mA switching capacity
DC power supply reverse polarity Operation indicator (red LED) - 25°C to 70°C ( - 13°F to 158°F) with no icing 35% to 95% 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Approx. 50 G's -- 1, 3, 4, 6, 12, 13 IP67 Approx. 30 g (1.1 oz.) Stainless steel Plastic PBT Polyvinyl chloride Nickel-plated brass Nickel-plated brass
Vibration resistance Shock resistance Enclosure rating UL NEMA IEC 144 Weight with cable Materials Housing Sensing face Cable sheath
5
E2E 3 -Wire DC
J STANDARD SIZE SENSORS
Part number Size Type Sensing distance E2E-X1R5 Ej/Fj M8 Shielded 1.5 mm (0.06 in) ±10% Unshielded 2 mm (0.08 in) ±10% E2E-X2ME j/ Fj E2E-X2Ej / Fj M12 Shielded 2 mm (0.08 in) ±10% Unshielded 5 mm (0.20 in) ±10% E2E-X5ME j/Fj E2E-X5Ej / Fj M18 Shielded 5 mm (0.20 in) ±10% Unshielded 10 mm (0.39 in) ±10% E2E-X10M Ej/Fj
E2E 3 -Wire DC
E2E-X10E j/ Fj M30 Shielded 10 mm (0.39 in) ±10%
E2E-X18M Ej/ Fj Unshielded 18 mm (0.71 in) ±10%
Supply voltage (operating voltage range) (See Note 1.) Current consumption Sensing object Setting distance
12 to 24 VDC, ripple (p-p): 10% max., (10 to 40 VDC)
13 mA max. Magnetic metals (refer to Engineering Data for non-magnetic metals) 0 to 1.2 mm (0 to 0.05 in) 8x8x 1 mm (0.31 x 0.31 x 0.04 in) 2.0 kHz 0 to 1.6 mm (0 to 0.06 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 0.8 kHz 0 to 1.6 mm (0 to 0.06 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 1.5 kHz 0 to 4.0 mm (0 to 0.16 in) 15 x 15 x 1 mm (0.59 x 0.59 x 0.04 in) 0.4 kHz 0 to 4.0 mm (0 to 0.16 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 0.6 kHz 0 to 8.0 mm (0 to 0.31 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 0.2 kHz 0 to 8.0 mm (0 to 0.31 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 0.4 kHz 0 to 14.0 mm (0 to 0.55 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in) 0.1 kHz
Standard object (mild steel)
Differential travel Response frequency Operation (with sensing object approaching) Control output (switching capacity) Circuit protection Indicator Ambient temperature (See Note 2.) Ambient humidity Temperature influence Voltage influence Residual voltage Insulation resistance Dielectric strength Vibration resistance Shock resistance
10% max. of sensing distance E1 models: Load ON E2 models: Load OFF 200 mA max. Reverse connection protection, surge absorber, load short-circuit protection Operation indicator (red LED) Operating: - 40°C to 85°C ( - 40°F to 185°F) with no icing Operating: 35% to 95% ±15% max. of sensing distance at 23°C in temperature range of - 40°C to 85°C ( - 40°F to 185°F) ±10% max. of sensing distance at 23°C in temperature range of - 25°C to 70°C ( - 13°F to 158°F) ±1% max. of sensing distance in rated voltage range ±15% 2.0 V max. (under load current of 200 mA with cable length of 2 m) 50 M min. (at 500 VDC) between current carry parts and case 1,000 VAC for 1 min. between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z axes 500 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes IP67 1, 4, 6, 12, 13 Approx. 45 g --Approx. 25 g Brass Approx. 120 g Approx. 160 g Approx. 45 g Approx. 270 g Approx. 125 g Approx. 124 g 1,000 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes 500 m/s2 (approx. 50G) for E2E-X5M
Enclosure rating Weight
IEC NEMA Pre-wired Connector
Material
Body Sensing face
Stainless steel PBT
Note: 1. E2E models with an M18 or M30 connector operate at a non-smoothed, all-wave rectified, mean voltage range of 24 VDC ±20%. 2. When using an E2E with an M8 connector at an ambient temperature range between 70°C and 85°C (158°F and 185°F), supply 10 to 30 VDC to the E2E and make sure that the E2E has a control output of 100 mA maximum.
6
Others parts begin by e2
E2-1 E2-2 E2-3 E2-4 E2-5 E2-6 E2-7 E2-8 E2-9 E2-10
|
|
|