Short Barrel Inductive Prox
Short Barrel 2-Wire AC Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench
flats for easy installation H Solid potted internal circuitry withstands shocks and water washdown to IP67 H High visibility indicator H Choose prewired models with or without short-circuit protection and connector models

E2E 2 -WIRE AC

Ordering Information
J PREWIRED SENSORS WITHOUT SHORT-CIRCUIT PROTECTION

Type Shielded

Size M8 M12 M18 M30

Sensing distance .5 mm 1 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm

Part number NO E2E-X1R5Y1 E2E-X2Y1-US E2E-X5Y1-US E2E-X10Y1-US E2E-X2MY1-US E2E-X5MY1-US E2E-X10MY1-US E2E-X18MY1-US NC E2E-X1R5Y2 E2E-X2Y2-US E2E-X5Y2-US E2E-X10Y2-US E2E-X2MY2-US E2E-X5MY2-US E2E-X10MY2-US E2E-X18MY2-US

Unshielded

M8 M12 M18 M30

18 mm *Note: A different oscillating frequency is available to prevent mutual interference. Add a "5" to the part number (e.g., E2E-X5Y15-US).

2

E2E 2 -WIRE AC
J PREWIRED SENSORS WITH SHORT-CIRCUIT PROTECTION
Type Shielded Size M18 M30 Unshielded M18 M30 18 mm Sensing distance Part number NO 5 mm 10 mm 10 mm E2E-X5Y1-53-US E2E -X10Y1-53-US E2E-X10MY1-53-US E2E-X18MY1-53-US NC E2E-X5Y2-53-US E2E -X10Y2-53-US

E2E 2 -WIRE AC

E2E-X10MY2-53-US E2E-X18MY2-53-US

J SENSORS WITH BUILT-IN CONNECTORS
Connector 4-pin connector (M12) See Note 1. Type Shielded Size M12 M18 M30 Unshielded M12 M18 M30 18 mm 3-pin connector (M12) See Note 2. Shielded M12 M18 M30 Unshielded M12 M18 M30 18 mm Note: 1. Use Omron's Y96E-44jAj connector cordsets. 2. Use Omron's Y96E-33jAj connector cordsets. 2 mm 5 mm 10 mm 5 mm 10 mm E2E-X2Y1-M4 E2E-X5Y1-M4 E2E-X10Y1-M4 E2E-X5MY1-M4 E2E-X10MY1-M4 E2E-X18MY1-M4 E2E-X2Y2-M4 E2E-X5Y2-M4 E2E-X10Y2-M4 E2E-X5MY2-M4 E2E-X10MY2-M4 E2E-X18MY2-M4 Sensing distance Part number NO 2 mm 5 mm 10 mm 5 mm 10 mm E2E-X2Y1-M1 E2E-X5Y1-M1 E2E-X10Y1-M1 E2E-X5MY1-M1 E2E-X10MY1-M1 E2E-X18MY1-M1 NC E2E-X2Y2-M1 E2E-X5Y2-M1 E2E-X10Y2-M1 E2E-X5MY2-M1 E2E-X10MY2-M1 E2E-X18MY2-M1

J ACCESSORIES
Description Mounting brackets Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors See Y96E Connector Cordsets data sheet for details Part number Y92E -B8 Y92E -B12 Y92E -B18 Y92E -B30 Y92E -E12-2 Y92E -E18-2 Y92E -E30-2

Silicone rubber covers for shielded sensors Connector cordsets

3

E2E 2 -WIRE AC
J REPLACEMENT PARTS
Description Mounting hardware including one pair of metal nuts and one washer Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Part number M8-MHWS M12-MHWS M18-MHWS M30-MHWS

E2E 2 -WIRE AC

Specifications
J SENSORS WITHOUT SHORT-CIRCUIT PROTECTION (E2E-XjYj)
Part number Size Type Sensing distance
E2E-X1R5Yj E2E-X2MYj E2E-X2Yj -US E2E-X5MY j -US E2E-X5Y j -US E2E-X10MY j -US E2E-X10Y j -US E2E-X18MY j -US

M8
Shielded Unshielded

M12
Shielded Unshielded

M18
Shielded Unshielded

M30
Shielded Unshielded

1.5 mm (0.06 in) ±10%

2 mm (0.08 in) ±10%

2 mm (0.08 in) ±10%

5 mm (0.20 in) ±10%

5 mm (0.20 in) ±10%

10 mm (0.39 in) ±10%

10 mm (0.39 in) ±10%

18 mm (0.71 in) ±10%

Supply voltage (operating voltage range) (See note 1) Current consumption Sensing object Setting distance

24 to 240 VAC, 50/60 Hz (20 to 264 VAC)

1.7 mA max. Magnetic metals (refer to Engineering Data for non-magnetic metals) 0 to 1.2 mm (0 to 0.05 in) 8 x 8 x 1 mm (0.31 x 0.31 x 0.04 in) 0 to 1.6 mm (0 to 0.06 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 0 to 1.6 mm (0 to 0.06 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 0 to 4.0 mm (0 to 0.16 in) 15 x 15 x 1 mm (0.59 x 0.59 x 0.04 in) 0 to 4.0 mm (0 to 0.16 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 0 to 8.0 mm (0 to 0.31 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 0 to 8.0 mm (0 to 0.31 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 0 to 14.0 mm (0 to 0.55 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in)

Standard object (mild steel)

Differential travel Response frequency Operation (with sensing object approaching) Control output (switching capacity) Indicator Ambient temperature (See note 2) Ambient humidity Temperature influence Voltage influence Residual voltage Insulation resistance Dielectric strength Vibration resistance Shock resistance Enclosure rating IEC NEMA

10% max. of sensing distance 25 Hz Y1 models: Load ON Y2 models: Load OFF 5 to 100 mA max. Operation indicator (red LED) Operating: - 25°C to 70°C ( - 13°F to 158°F) with no icing Operating: 35% to 95% ±15% max. of sensing distance at 23°C in temperature range of - 40°C to 85°C ( - 40°F to 185°F) ±10% max. of sensing distance at 23°C in temperature range of - 25°C to 70°C ( - 13°F to 158°F) ±1% max. of sensing distance in rated voltage range ±15% Refer to Engineering Data 50 M min. (at 500 VDC) between current carry parts and case 4,000 VAC for 1 min between current carry parts and case (2,000 VAC for M8 types) 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions 500 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes IP67 1, 4, 6, 12, 13 1,000 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes 500 m/s2 (approx. 50G) for E2E-X5M Operating: - 40°C to 85°C ( - 40°F to 185°F) with no icing 5 to 200 mA max. 5 to 300 mA max.

Note: 1. When using an M18 or M30 size E2E at an ambient temperature between 70°C and 85°C (158°F and 185°F), make sure that the E2E has a control output of 200 mA maximum. 2. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is - 25°C to 85°C ( - 13°F to 185°F). (This table continues on the next page.)

4

E2E 2 -WIRE AC
Specifications Table -- continued from previous page
Part number Approvals Weight UL C SA Prewired Connector Material Body Sensing face
E2E-X1R5Y j E2E-X2MY j E2E-X2YjUS E2E-X5MYj -US E2E-X5Yj US E2E-X10MY j -US

E2E 2 -WIRE AC
E2E-X10Y j -US E2E-X18MY j -US

Approx. 45 g --Approx. 25 g

Recognized, File Number E76675 Certified, File Number LR45951 Approx. 120 g Approx. 160 g Approx. 45 g Brass Approx. 270 g Approx. 125 g Approx. 124 g

Stainless steel PBT

J SENSORS WITH SHORT-CIRCUIT PROTECTION (E2E-XjYj-53 -US)
Part number Body Supply voltage Effective maximum detecting distance (with standard target) Usable detecting range (with standard target) Standard target size (mild steel, L x W x H) Differential travel Control output AC solid state Type Max. load Min. load Max. offstate leakage current Max. on-state voltage drop Response frequency Circuit protection Output short-circuit Weld field immunity RFI immunity Indicators Materials Housing Sensing face Cable sheath Mounting Connections Weight with cable Enclosure ratings Approvals UL NEMA IEC 144 UL C SA Ambient operating temperature Vibration Shock Prewired Size Type E2E-X5Yj-53-US M18 Shielded 5 mm (0.20 in) ±10% 0 to 4 mm (0 to 0.16 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) Unshielded 10 mm (0.40 in) ±10% 0 to 8 mm (0 to 0.31 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 90 to 140 VAC, 50/60 Hz 18 mm (0.71 in) ±10% 0 to 14 mm (0 to 0.55 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in) E2E-X10MYj-53-US E2E-X10Yj-53-US M30 Shielded Unshielded E2E-X18MYj-53-US

10% max. of effective detecting distance SCR-NO (E2E-XjjjY1-jj-jj) SCR-NC (E2E-XjjjY2-jj-jj) 300 mA 5 mA 1.5 mA (See "Leakage Current Characteristics" graph in Engineering Data.) (See "Leakage Current Characteristics" graph in Engineering Data.) 25 Hz Provided Not provided Not provided Target present (red LED) Nickel-plated brass Plastic Plastic Two lock washers and M18 nuts included. Bracket Y92E-B18 optional. 2-conductor cable, 2 m (6.56 ft) length Approx. 160 g (5.6 oz.) 1 1, 4, 6, 12, 13 IP67 Recognized, File Number E76675 Certified, File Number LR45951 -25° to 70°C (-13° to 158°F) 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Approx. 100 G's Approx. 270 g (9.5 oz.) Two lock washers and M30 nuts included. Bracket Y92E-B30 optional.

5

E2E 2 -WIRE AC

E2E 2 -WIRE AC

Operation
J OUTPUT CIRCUITS
Sensors without Short-Circuit Protection (E2E -XjYj) E2E -XjYj AC 2 -wire Models
Brown 1 (or 3) Load Mai n circuit Blue 2 (or 4)

AC 2 -wire Models
E2E-XjYj
S ens i ng obj ec t Red i n d i c a to r Control output Yes No Li t Not lit ON OFF

Sensors with Short-Circuit Protection (E2E -XjYj-US -53)
White (Brown) Load

Prox. switch mai n circuit Black (Blue)

Note: IEC colors are shown in parenthesis With Short -Circuit Protection E2E-XjY1-53 NO
Load Target Output Output operation i ndi c ator Shorted Normal Present A bs ent ON OFF ON OFF

E2E-XjY2-53 NC
Shorted Normal Present A bs ent ON OFF ON OFF

Short -Circuit Indication The LED dims when the load is shorted and the load output immediately turns off and remains off until the short-circuit protection is reset. Resetting Short -Circuit Protection Before the short-circuit protection can be reset, the short must be repaired. We recommend turning the power off before repairing the short. If this approach is taken, no further action is required to reset the short-circuit protection. If the short must be repaired with power on, the following resetting steps are required: For NO sensors, the target must be removed to reset the short-circuit protection. For NC sensors, the target must be presented then removed to reset the short-circuit protection.