Part: DMF-5001NYL
Category: Optoelectronics -> Display -> LCD Display -> Graphic -> Monochrome-Graphic
Description: Size:4.7 Display Format:160*128 Contrast Ratio:8:1 Luminance:n/a Backlight:no Backlight Product Category:monochrome-graphic Type:reflective LCD Mode:yellow/dark Blue Viewing Direction: 9:00 Interface: N/a View Angle (h V):-40/40 -40/35 Temperature: Normal
Company: Optrex
Datasheet: Download DMF-5001NYL datasheet File size : 984 kB
Request For quote: Find where to buy DMF-5001NYL
Datasheet text preview:
First Edition
Approved by
Production Div.
June 12, 1998
LCD Module Specification
Checked by
Quality Assurance Div.
Final Revision Checked by Design Engineering Div.
*******
Prepared by Type No. Production Div.
Table of Contents
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. General Specifications ...........2 Electrical Specifications.........3 Optical Specifications ......6 I/O Terminal............8 Test..........10 Appearance Standards..........11 Code System of Production Lot ..........14 Type Number.........14 Applying Precautions ...........14 Handling Precautions ...........15
Revision History
Rev. Date Page Comment
DMF5001NYL (AC) No.98-0143
OPTREX
OPTREX CORPORATION
Page 1/15
1 . G e n e r a l Specif i c a t i o n s
Operating Temp. Storage Temp. Dot Pixels Dot Size Dot Pitch Viewing Area Outline Dimensions Weight LCD Type
min. 0 max. 50 min. -20 max. 60 160 (W) × 128 (H) dots 0.54 (W) × 0.54 (H) mm 0.58 (W) × 0.58 (H) mm 101.0 (W) × 82.0 (H) mm 129.0 (W) × 102.0 (H) × 12.8 max. (D) mm 120g max. NRD-7353 ( STN / Neutral -mode / Reflective ) 9:00 T6963C-0101 (Produced by TOSHIBA) 8-bit data transfer None Dimensional Outline UE-31324A
Viewing Angle Control LSI Data Transfer Backlight Drawings
DMF5001NYL (AC) No.98-0143
OPTREX
OPTREX CORPORATION
Page 2/15
2 . E l e c t r i c a l Specif i c a t i o n s
2.1.Absolute Maximum Ratings VSS=0V Parameter Supply Voltage (Logic) Supply Voltage (LCD Drive) Input Voltage VI -0.3 VDD+0.3 V VDD-VEE 0 28.0 V Symbol VDD-VSS Conditions Min. -0.3 Max. 7.0 Units V
2.2.DC Characteristics Ta=25, VSS=0V Parameter Supply Voltage (Logic) VDD-VEE Supply Voltage (LCD Drive) VDD-VCONT Shown in 3.1 V 23.0 26.0 V Symbol VDD-VSS Conditions Min. 4.5 Typ. Max. 5.5 Units V
High Level Input Voltage Low Level Input Voltage High Level Output Voltage Low Level Output Voltage
VIH
VDD=5.0Vą10%
VDD-2.2
VDD
V
VIL
VDD=5.0Vą10%
0
0.8
V
VOH
IOH=-0.75mA
VDD-0.3
VDD
V
VOL
IOL=0.75mA
0
0.3
V
IDD Supply Current IEE
VDD-VSS=5.0V
13.4
30.0
mA
VDD-VCONT=19.4V
3.7
20.0
mA
DMF5001NYL (AC) No.98-0143
OPTREX
OPTREX CORPORATION
Page 3/15
2.3.AC Characteristics VDD=5.0Vą10% Parameter C/D Setup Time C/D Hold Time CE, RD, WR Pulse Width Data Setup Time Data Hold Time Access Time Output Hold Time Symbol Min. 100 10 80 80 40 10 Max. 150 50 Units ns ns ns ns ns ns ns
tCDS tCDH tCE, tRD, tWR tDS tDH tACC tOH
C/D
tCDS
CE
tCDH
tCE, tRD, tWR
RD, WR
tDS
D0D7 (WRITE)
tDH
tACC
D0D7 (READ)
tOH
DMF5001NYL (AC) No.98-0143
OPTREX
OPTREX CORPORATION
Page 4/15
2.4.Power Supply ON/OFF Sequence 2.4.1.ON Sequence
SIGNAL LEVEL VDD VDD
0t
VSS VDD VSS VDD VSS VCONT VEE
SIGNAL (W ithout RESET and HALT Signal) VCONT VEE
0t
2.4.2.OFF Sequence
LEVEL VDD VSS VDD VSS VDD VSS VCONT VEE
0t
SIGNAL
VDD
0t
SIGNAL (W ithout RESET and HALT Signal) VCONT VEE
2.4.3.Reset Sequence
SIGNAL LEVEL H Level RESET HALT L Level VDD VSS VDD VCONT
Power On Reset Reset Cancellation Power Off
T>250 s
T0 T10 ms
V DD VCONT
T50ms
T0
T50ms
T0
Please maintain the above sequence when turning on and off the power supply of the module. If VEE and/or VCONT is supplied to the module while internal alternate signal for LCD driving (M) is unstable or RESET and HALT is active, DC component will be supplied to the LCD panel. This may cause damage to the LCD module.
DMF5001NYL (AC) No.98-0143
OPTREX
OPTREX CORPORATION
Page 5/15
Others parts begin by dm
|
|
|