Details, datasheet, quote on part number:ER1001ACT
| |
Datasheet text preview:
DATA SHEET
ER1000CT~ER1004CT
SUPERFAST RECOVERY RECTIFIERS
VOLTAGE
FEATURES
50 to 400 Volts
CURRENT
10 Amperes
TO - 2 2 0 A B
Unit : inch (mm)
.419(10.66)
.196(5.00) .163(4.16) .054(1.39) .045(1.15)
.269(6.85) .226(5.75)
· Plastic package has Underwriters Laboratory Flammability Classification 94V-O. Flame Retardant Epoxy Molding Compound. · Exceeds environmental standards of MIL-S-19500/228 · Low power loss, high efficiency. · Low forwrd voltge, high current capability · High surge capacity. · Super fast recovery times, high voltage.
.387(9.85) .139(3.55) MIN
.624(15.87) .50(12.7)MIN
MECHANICAL DATA
Case: TO-220AB Molded plastic Terminals: Lead solderable per MIL-STD-202, Method 208 Polarity: As marked. Standard packaging: Any Weight: 0.08 ounces, 2.24grams.
.038(0.96) .019(0.50)
.177(4.5)MAX
.548(13.93)
.025(0.65)MAX
.1(2.54)
.1(2.54)
AC Positive CT AC
MAXIMUM RATING AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%
PARAMETER Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Current .375"(9.5mm) lead length at Tc =100OC Peak Forward Surge Current, 8.3ms single half sine-wave superimposed on rated load(JEDEC method) Maximum Forward Voltage at 5A, per element Maximum DC Reverse Current at Rated DC Blocking VoltageTA=25 C Maximum DC Reverse Current at Rated DC Blocking VoltageTA=100OC
O
SYMBOL VRRM VRMS VDC IAV IFSM VF IR TRR CJ RJC TJ,TSTG
ER1000CT ER1001CT ER1001ACT ER1002CT ER1003CT ER1004CT UNITS 50 35 50 100 70 100 150 105 150 10.0 150 0.95 10 500 35 62 3.0 -50 TO +150
O
200 140 200
300 210 300
400 280 400
V V V A A
1.30
V uA
Maximum Reverse Recovery Time (Note 2) Typical Junction capacitance (Note 1) Maximum Thermal Resistance Operating Junction and Storage Temperature Range
50
ns pF C/W
O
C
NOTES: 1. Measured at 1 MHz and applied reverse voltage of 4.0 VDC. 2. Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=.25A.
STAD-SEP.05.2003
PAGE . 1
R AT I N G A N D C H A R A C T E R I S T I C C U R V E S
AV E R A G E F O R WA R D C U R R E N T, AMPERES
8 6 4
.375" 9.5mm LEAD LENGHTS R E S I S T I V EO RI N D U C T I V E L O A D
PEAK FORWARD SURGE CURRENT,
10
150 125 100 75 50 25 0
8.3ms Single Half Since-Wave JEDEC Method
2 0 0 20 40 60 80 100
O
120
140
160
1
2
5
10
20
50
100
CASE TEMPERAURE, C Fig.1- FORWARD CURRENT DERATING CURVE
NO. OF CYCLE AT 60HZ
Fig.2- MAXIMUM NON - REPETITIVE SURGE CURRENT
10
3
10 50-200V
R E V E R S E C U R R E N T, u A
10
2
TJ=125 C
O
F O R WA R D C U R R E N T, A M P E R E S
300-400V
10
1
1.0
10
0
10
-1
T J= 2 5 C
O
TA=2 5 C 0.1 0.4
O
10
-2
20
40
60
80
100
120
0.6
0.8
1.0
1.2
1.4
P E R C E N T O F R AT E D P E A K R E V E R S E V O LTA G E , %
F O R WA R D V O L AT G E , V O LT S
Fig.3- TYPICAL REVERSE CHARACTERISTIC
Fig.4- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTIC
STAD-SEP.05.2003
PAGE . 2
|
|