Off-Line PC Mount Transformer
ELECTRONICS INC.
EPC3090-X
· Single Primary : 115 V · Split Bobbin Construction · UL 94V-0 Recognized Components · UL 1446 Class B Insulation System · Meets or exceeds CSA/TUV/VDE Specifications for Creepage, Clearance and Dielectric Strength
Electrical Parameters @ 25° C
Part Number EPC3090-1 EPC3090-2 EPC3090-3 EPC3090-4 EPC3090-5 EPC3090-6 EPC3090-7 EPC3090-8 EPC3090-9 EPC3090-10 Primary Voltage 115 115 115 115 115 115 115 115 115 115 Secondary Voltage Parallel Series Connection Connection Secondary Current (A-Rms) Parallel Series Connection Connection 0.25 0.20 0.15 0.12 0.10 0.085 0.065 0.050 0.045 0.020 Power Rating (VA) 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
0.50 10 5.0 0.40 12.6 6.3 0.30 16 8.0 0.24 20 10 0.20 24 12 0.17 28 14 0.13 36 18 0.10 48 24 0.09 56 28 0.04 120 60 · Switching Frequency : 50 Hz - 500 Hz · Isolation : 2500 Vrms ·
Package
1.370 (34.90) 1.120 (28.60) Pri.
Schematic
Sec. 5 6 7 8
4 1.180 (30.10) 1
.280 (7.11) .250 (6.35) .041(1.04) .250 (6.35) .750 (19.05) 1 4 1.200 (30.50)
Notes : 1. Optional Mounting Screws and Nut : None 2. Pins 2 and 3 omitted
5
6
7
8 Clearance Hole
Unless Otherwise Specified Dimensions are in Inches /mm ± .010 /.25 PCA ELECTRONICS, INC. 16799 SCHOENBORN ST. NORTH HILLS, CA 91343
Product performance is limited to specified parameters. Data is subject to change without prior notice.
CSC3090-X Rev. 7/15/02