INTEGRATED CIRCUITS

DATA SHEET
For a complete data sheet, please also download:
· The IC06 74HC/HCT/HCU/HCMOS Logic Family Specifications · The IC06 74HC/HCT/HCU/HCMOS Logic Package Information · The IC06 74HC/HCT/HCU/HCMOS Logic Package Outlines

74HC/HCT4040 12-stage binary ripple counter
Product specification File under Integrated Circuits, IC06 December 1990

Philips Semiconductors

Product specification

12-stage binary ripple counter
FEATURES · Output capability: standard · ICC category: MSI GENERAL DESCRIPTION The 74HC/HCT4040 are high-speed Si-gate CMOS devices and are pin compatible with "4040" of the "4000B" series. They are specified in compliance with JEDEC standard no. 7A. The 74HC/HCT4040 are 12-stage binary ripple counters with a clock input (CP), an overriding asynchronous master reset input (MR) and twelve parallel outputs QUICK REFERENCE DATA GND = 0 V; Tamb = 25 °C; tr = tf = 6 ns

74HC/HCT4040
(Q0 to Q11). The counter advances on the HIGH-to-LOW transition of CP. A HIGH on MR clears all counter stages and forces all outputs LOW, independent of the state of CP. Each counter stage is a static toggle flip-flop. APPLICATIONS · Frequency dividing circuits · Time delay circuits · Control counters

TYPICAL SYMBOL tPHL/ tPLH PARAMETER propagation delay CP to Q0 Qn to Qn+1 fmax CI CPD Notes 1. CPD is used to determine the dynamic power dissipation (PD in µW): PD = CPD × VCC2 × fi + (CL × VCC2 × fo) where: fi = input frequency in MHz fo = output frequency in MHz (CL × VCC2 × fo) = sum of outputs CL = output load capacitance in pF VCC = supply voltage in V 2. For HC the condition is VI = GND to VCC For HCT the condition is VI = GND to VCC - 1.5 V ORDERING INFORMATION See "74HC/HCT/HCU/HCMOS Logic Package Information". maximum clock frequency input capacitance power dissipation capacitance per package notes 1 and 2 CONDITIONS HC CL = 15 pF; VCC = 5 V 14 8 90 3.5 20 16 8 79 3.5 20 ns ns MHz pF pF HCT UNIT

December 1990

2

Philips Semiconductors

Product specification

12-stage binary ripple counter
PIN DESCRIPTION PIN NO. 8 9, 7, 6, 5, 3, 2, 4, 13, 12, 14, 15, 1 10 11 16 SYMBOL GND Q0 to Q11 CP MR VCC NAME AND FUNCTION ground (0 V) parallel outputs

74HC/HCT4040

clock input (HIGH-to-LOW, edge-triggered) master reset input (active HIGH) positive supply voltage

Fig.1 Pin configuration.

Fig.2 Logic symbol.

Fig.3 IEC logic symbol.

December 1990

3

Philips Semiconductors

Product specification

12-stage binary ripple counter

74HC/HCT4040
FUNCTION TABLE INPUTS CP X Notes MR L L H OUTPUTS Qn no change count L

Fig.4 Functional diagram.

1. H = HIGH voltage level L = LOW voltage level X = don't care = LOW-to-HIGH clock transition = HIGH-to-LOW clock transition

Fig.5 Logic diagram.

Fig.6 Timing diagram.

December 1990

4

Philips Semiconductors

Product specification

12-stage binary ripple counter
DC CHARACTERISTICS FOR 74HC For the DC characteristics see "74HC/HCT/HCU/HCMOS Logic Family Specifications". Output capability: standard ICC category: MSI AC CHARACTERISTICS FOR 74HC GND = 0 V; tr = tf = 6 ns; CL = 50 pF Tamb (°C) 74HC SYMBOL PARAMETER min. tPHL/ tPLH propagation delay CP to Q0 propagation delay Qn to Qn+1 propagation delay MR to Qn output transition time +25 typ. 47 17 14 28 10 8 61 22 18 19 7 6 80 16 14 80 16 14 50 10 9 6.0 30 35 14 5 4 22 8 6 8 3 2 27 82 98 -40 to +85 max. min. 150 30 26 100 20 17 185 37 31 75 15 13 100 20 17 100 20 17 65 13 11 4.8 24 28 max. 190 38 33 125 25 21 230 46 39 95 19 16 120 24 20 120 24 20 75 15 13 4.0 20 24 -40 to +125 min. max. 225 45 38 150 30 26 280 56 48 110 22 19 ns

74HC/HCT4040

TEST CONDITIONS UNIT VCC WAVEFORMS (V) 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 2.0 4.5 6.0 Fig.7

tPHL/ tPLH

ns

Fig.7

tPHL

ns

Fig.7

tTHL/ tTLH

ns

Fig.7

tW

clock pulse width HIGH or LOW master reset pulse width; HIGH removal time MR to CP maximum clock pulse frequency

ns

Fig.7

tW

ns

Fig.7

trem

ns

Fig.7

fmax

MHz

Fig.7

December 1990

5