Part: CDD10810
Category: Discrete -> Diodes & Rectifiers
Description: Dual Diode Pow-r-blok Modules 100 Amperes/800 Volts
Company: Powerex, Inc.
Datasheet: Download CDD10810 datasheet File size : 1567 kB
Request For quote: Find where to buy CDD10810
Datasheet text preview:
CDD10810
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Dual Diode POW-R-BLOKTM Modules
100 Amperes/800 Volts
A B 1 2 3 H K - DIA. (2 TYP.) D
G
E
E
L - M5 THD (3 TYP.)
C
A
F J 1 2 3
CDD10810 Dual Diode POW-R-BLOKTM Modules 100 Amperes/800 Volts
Description: Powerex Dual Diode POW-R-BLOKTM Modules are designed for use in applications requiring AC to DC rectification in isolated packaging. The modules are isolated for easy mounting with other components on common heatsinks. POW-R-BLOKTM has been tested and recognized by Underwriters Laboratories (QQQX2 Power Switching Semiconductors). Features: Isolated Mounting Glass Passivated Chips
Outline Drawing
Metal Baseplate Low Thermal Impedance
Millimeters 93.5 Max. 80 30 Max. 26 Max. 21 20 17.5 12.5 6.5 Dia. 6.5 M5
Dimension A B C D E F G H J K L
Inches 3.68 Max. 3.150 1.181 Max. 1.024 Max. 0.827 0.787 0.689 0.492 0.256 0.256 Dia. M5 Metric
UL Recognized A Applications: Battery Supplies AC and DC Motor Power Supplies Ordering Information: Select the complete eight digit module part number you desire from the table below. Example: CDD10810 is an 800 Volt, 100 Ampere Dual Diode POW-R-BLOKTM Module.
Type CDD1 Voltage Volts (x100) 08 Current Rating Amperes (x10) 10
D-111
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CDD10810 Dual Diode POW-R-BLOKTM Modules 100 Amperes/800 Volts
Absolute Maximum Ratings
Characteristics Peak Reverse Blocking Voltage Transient Peak Reverse Blocking Voltage (Non-Repetitive), t < 5ms DC Reverse Blocking Voltage RMS On-State Current Average On-State Current, TC = 90°C Peak One-Cycle Surge (Non-Repetitive) On-State Current (60Hz) Peak One-Cycle Surge (Non-Repetitive) On-State Current (50Hz) I2t (for Fusing), 8.3 milliseconds Storage Temperature Operating Temperature Maximum Mounting Torque M6 Mounting Screw Maximum Mounting Torque M5 Terminal Screw Module Weight (Typical) V Isolation Symbol VRRM VRSM VR(DC) IF(RMS) IF(AV) IFSM IFSM I2t TSTG Tj -- -- -- VRMS CDD10810 800 960 640 155 100 2000 1800 16500 -40 to 125 -40 to 125 26 17 160 2000 Units Volts Volts Volts Amperes Amperes Amperes Amperes A2sec °C °C in.-lb. in.-lb. Grams Volts
D-112
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CDD10810 Dual Diode POW-R-BLOKTM Modules 100 Amperes/800 Volts
Electrical and Thermal Characteristics, Tj = 25°C unless otherwise specified
Characteristics Blocking State Maximums Reverse Leakage Current, Peak Conducting State Maximums Peak On-State Voltage Thermal Maximums Thermal Resistance, Junction-to-Case Thermal Resistance, Case-to-Sink (Lubricated) Symbol IRRM VFM R (J-C) R (C-S) Test Conditions Tj = 125°C, VRRM = Rated IFM = 320A Per Module Per Module CDD10810 15 1.25 0.3 0.2 Units mA Volts °C/Watt °C/Watt
D-113
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CDD10810 Dual Diode POW-R-BLOKTM Modules 100 Amperes/800 Volts
MAXIMUM ON-STATE CHARACTERISTICS
INSTANTANEOUS ON-STATE VOLTAGE, VFM, (VOLTS)
MAXIMUM ALLOWABLE PEAK SURGE (NON-REPETITIVE) CURRENT
MAXIMUM ALLOWABLE CASE TEMPERATURE
MAXIMUM ALLOWABLE CASE TEMPERATURE, TC, (oC)
2.4
MAXIMUM PEAK SURGE (NON-REPETITIVE) CURRENT, IFSM, (AMPERES)
2000
Tj = 25oC
140
OPERATION DC SINGLE-PHASE THREE-PHASE
2.0
1600
120
1.6
1200
100
1.2
800
80
0.8
400
60
RESISTIVE INDUCTIVE LOAD
0.4 100
101
102
103
0 100
40 0 40 80 120 160 200
AVERAGE ON-STATE CURRENT, IF(AV), (AMPERES)
101
CYCLES AT 60 HZ
102
INSTANTANEOUS ON-STATE CURRENT, IFM, (AMPERES)
MAXIMUM ON-STATE POWER DISSIPATION
MAXIMUM POWER DISSIPATION, PAV(MAX), (WATTS)
320
OPERATION DC SINGLE-PHASE THREE-PHASE
TRANSIENT THERMAL IMPEDANCE, Z (J-C)(t), (oC/WATT)
TRANSIENT THERMAL IMPEDANCE CHARACTERISTICS (JUNCTION-TO-CASE) 0 10 101
0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 10-3 10-2 10-1 100
240
160
80
RESISTIVE INDUCTIVE LOAD
0 0 40 80 120 160 200
AVERAGE ON-STATE CURRENT, IF(AV), (AMPERES)
TIME, t, (SECONDS)
D-114
Others parts begin by cd
CD-1 CD-2 CD-3 CD-4 CD-5 CD-6 CD-7 CD-8 CD-9 CD-10 CD-11 CD-12 CD-13 CD-14 CD-15 CD-16 CD-17 CD-18 CD-19 CD-20 CD-21 CD-22 CD-23 CD-24 CD-25 CD-26 CD-27 CD-28 CD-29 CD-30 CD-31 CD-32 CD-33 CD-34 CD-35 CD-36 CD-37
|
|
|