Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: 2SA1883

Category:
 Discrete
   -> Transistors
     -> Bipolar
       -> General Purpose

Description: PNP Epitaxial Planar Silicon Transistor, High Speed Switching Application

Company: Sanyo Semiconductor Corporation

Datasheet: Download 2SA1883 datasheet     File size : 159 kB

Request For quote: Find where to buy 2SA1883



Datasheet text preview:
Ordering number:4660A

PNP Epitaxial Planar Silicon Transistor

2SA1883
High-Speed Switching Applications
Features
· Fast switching speed. · Low collector saturatio voltage. · High gain-bandwidth product. · Small collector capacitance. · Very small-sized package permitting 2SA1883applied sets to be made small and slim. · Complementary pair with the 2SC4987.

Package Dimensions
unit:mm 2106A
[2SA1883]

1 : Base 2 : Emitter 3 : Collector

Specifications
Absolute Maximum Ratings at Ta = 25°C
Parameter Collector-to-Base Voltage Collector-to-Emitter Voltage Emitter-to-Base Voltage Collector Current Collector Current (Pulse) Base Current Collector Dissipation Junction Temperature Storage Temperature Symbol VCBO VCEO VEBO IC ICP IB PC Tj Tstg Conditions

SANYO : SMCP

Ratings ­15 ­15 ­5 ­200 ­500 ­40 150 150 ­55 to +150

Unit V V V mA mA mA mW

°C °C

Electrical Characteristics at Ta = 25°C
Parameter Collector Cutoff Current Emitter Cutoff Current DC Current Gain Gain-Bandwidth Product Output Capacitance Collector-to-Emitter Saturation Voltage Base-to-Emitter Saturation Voltage Symbol ICBO IEBO hFE fT* Cob* VCE(sat) VBE(sat) VCB=­8V, IE=0 VEB=­3V, IC=0 VCE=­1V, IC=­10mA VCE=­10V, IC=­10mA VCB=­5V, f=1MHz IC=­10mA, IB=­1mA IC=­10mA, IB=­1mA 50 450 80 1000 1.8 ­0.07 ­0.80 3.0 ­0.20 ­0.90 Conditions Ratings min typ max ­0.1 ­0.1 140 MHz pF V V Unit µA µA

Any and all SANYO products described or contained herein do not have specifications that can handle a p p l i c a t i o n s that require extremely high levels of reliability, s u c h as life-support systems, a i r c r a f t ' s c o n t r o l systems, o r other applications whose failure can be reasonably expected to result in serious p h y s i c a l and/or material damage. Consult with your SANYO representative nearest you before using a n y SANYO products described or contained herein in such applications. SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other p a r a m e t e r s ) listed in products specifications of any and all SANYO products described or contained herein.

SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquaters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
91098HA (KT)/81094MT BX-1673, BX-0842 No.4660­1/4

2SA1883
Parameter Collector-to-Base Breakdown Voltage Collector-to-Emitter Breakdown Voltage Emitter-to-Base Breakdown Voltage Turn-ON Time Storage Time Turn-OFF Time Symbol V(BR)CBO IC=­10µA, IE=0 V(BR)CEO IC=­1mA, RBE= V(BR)EBO ton tstg toff IE=­10µA, IC=0 See specified Test Circuit. See specified Test Circuit. See specified Test Circuit. Conditions Ratings min ­15 ­15 ­5 11 21 19 typ max Unit V V V ns ns ns

Marking : HA

Switching Time Test Circuit

No.4660­2/4

2SA1883

No.4660­3/4

2SA1883

Specifications of any and all SANYO products described or contained herein stipulate the performance, characteristics, and functions of the described products in the independent state, and are not guarantees of the performance, characteristics, and functions of the described products as mounted in the customer's products or equipment. To verify symptoms and states that cannot be evaluated in an independent device, the customer should always evaluate and test devices mounted in the customer's products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all s e m i c o n d u c t o r products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. I n the event that any and all SANYO products described or contained herein fall under strategic products (including services) controlled under the Foreign Exchange and Foreign Trade Control Law of Japan, s u c h products must not be exported without obtaining export license from the Ministry of I n t e r n a t i o n a l Trade and Industry in accordance with the above law. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or m e c h a n i c a l , i n c l u d i n g photocopying and recording, o r any information storage or retrieval system, o r otherwise, w i t h o u t the prior written permission of SANYO Electric Co. , L t d . Any and all information described or contained herein are subject to change without notice due to product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification" for the SANYO product that you intend to use. I n f o r m a t i o n (including circuit diagrams and circuit parameters) herein is for example only ; i t is not g u a r a n t e e d for volume production. SANYO believes information herein is accurate and reliable, b u t no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties.
This catalog provides information as of September, 1998. Specifications and information herein are subject to change without notice.
PS No.4660­4/4




Others parts begin by 2s
2S-1   2S-2   2S-3   2S-4   2S-5   2S-6   2S-7   2S-8   2S-9   2S-10   2S-11   2S-12   2S-13   2S-14   2S-15   2S-16   2S-17   2S-18   2S-19   2S-20   2S-21   2S-22   2S-23   2S-24   2S-25   2S-26   2S-27   2S-28   2S-29   2S-30   2S-31   2S-32   2S-33   2S-34   2S-35   2S-36   2S-37   2S-38   2S-39   2S-40   2S-41   2S-42   2S-43   2S-44   2S-45   2S-46   2S-47   2S-48   2S-49