Datasheet text preview:
Ordering number:EN3096

PNP/NPN Epitaxial Planar Silicon Transistors

2SA1709/2SC4489
High-Voltage Switching Applications
Features
· Adoption of FBET, MBIT processes. · High breakdown voltage, large current capacity. · Fast switching speed.

Package Dimensions
unit:mm 2064
[2SA1709/2SC4489]

( ) 2SA1709

E : Emitter C : Collector B : Base SANYO : NMP

Specifications
Absolute Maximum Ratings at Ta = 25°C
Parameter Collector-to-Base Voltage Collector-to-Emitter Voltage Emitter-to-Base Voltage Collector Current Collector Current (Pulse) Collector Dissipation Junction Temperature Storage Temperature Symbol VCBO VCEO VEBO IC ICP PC Tj Tstg Conditions

Ratings (­)120 (­)100 (­)6 (­)2 (­)3 1 150 ­55 to +150

Unit V V V A A W °C

°C

Electrical Characteristics at Ta = 25°C
Parameter Collector Cutoff Current Emitter Cutoff Current DC Current Gain Gain-Bandwidth Product Collector-to-Emitter Saturation Voltage Base-to-Emitter Saturation Voltage Output Capacitance Symbol ICBO IEBO hFE fT VCE(sat) VBE(sat) Cob VCB=(­)100V, IE=0 VEB=(­)4V, IC=0 VCE=(­)5V, IC=(­)100mA VCE=(­)10V, IC=(­)100mA IC=(­)1A, IB=(­)100mA IC=(­)1A, IB=(­)100mA VCB=(­)10V, f=1MHz 100* 120 (­0.22) 0.13 (­)0.85 (25)16 (­0.6) 0.4 (­)1.2 Conditions Ratings min typ max (­)100 (­)100 400* MHz V V V pF Unit nA nA

Any and all SANYO products described or contained herein do not have specifications that can handle a p p l i c a t i o n s that require extremely high levels of reliability, s u c h as life-support systems, a i r c r a f t ' s c o n t r o l systems, o r other applications whose failure can be reasonably expected to result in serious p h y s i c a l and/or material damage. Consult with your SANYO representative nearest you before using a n y SANYO products described or contained herein in such applications. SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other p a r a m e t e r s ) listed in products specifications of any and all SANYO products described or contained herein.

SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquaters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
83098HA (KT)/5169MO, TS No.3096­1/5

2SA1709/2SC4489
Parameter Collector-to-Base Breakdown Voltage Collector-to-Emitter Breakdown Voltage Emitter-to-Base Breakdown Voltage Turn-ON Time Storage Time Fall Time Symbol V(BR)CBO IC=(­)10µA, IE=0 V(BR)CEO IC=(­)1mA, RBE= V(BR)CEO IE=(­)10µA, IC=0 ton See specified Test Circuit tstg tf See specified Test Circuit See specified Test Circuit Conditions Ratings min (­)120 (­)100 (­)6 80 (750) 1000 (40)50 typ max Unit V V V ns ns ns ns

* : The 2SA1709/2SC4489 are classified by 100mA hFE as follows :
100 R 200 140 S 280 200 T 400

Switching Time Test Circuit

Unit (resistance : , capacitacne : F)

No.3096­2/5

2SA1709/2SC4489

No.3096­3/5

2SA1709/2SC4489

No.3096­4/5

2SA1709/2SC4489

Specifications of any and all SANYO products described or contained herein stipulate the performance, characteristics, and functions of the described products in the independent state, and are not guarantees of the performance, characteristics, and functions of the described products as mounted in the customer's products or equipment. To verify symptoms and states that cannot be evaluated in an independent device, the customer should always evaluate and test devices mounted in the customer's products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all s e m i c o n d u c t o r products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. I n the event that any and all SANYO products described or contained herein fall under strategic products (including services) controlled under the Foreign Exchange and Foreign Trade Control Law of Japan, s u c h products must not be exported without obtaining export license from the Ministry of I n t e r n a t i o n a l Trade and Industry in accordance with the above law. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or m e c h a n i c a l , i n c l u d i n g photocopying and recording, o r any information storage or retrieval system, o r otherwise, w i t h o u t the prior written permission of SANYO Electric Co. , L t d . Any and all information described or contained herein are subject to change without notice due to product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification" for the SANYO product that you intend to use. I n f o r m a t i o n (including circuit diagrams and circuit parameters) herein is for example only ; i t is not g u a r a n t e e d for volume production. SANYO believes information herein is accurate and reliable, b u t no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties.
This catalog provides information as of August, 1998. Specifications and information herein are subject to change without notice.
PS No.3096­5/5




Others parts begin by 2s
2S-1   2S-2   2S-3   2S-4   2S-5   2S-6   2S-7   2S-8   2S-9   2S-10   2S-11   2S-12   2S-13   2S-14   2S-15   2S-16   2S-17   2S-18   2S-19   2S-20   2S-21   2S-22   2S-23   2S-24   2S-25   2S-26   2S-27   2S-28   2S-29   2S-30   2S-31   2S-32   2S-33   2S-34   2S-35   2S-36   2S-37   2S-38   2S-39   2S-40   2S-41   2S-42   2S-43   2S-44   2S-45   2S-46   2S-47   2S-48   2S-49