Part: 2SD1669
Category: Discrete -> Transistors -> Bipolar -> General Purpose
Description: NPN Epitaxial Planar Silicon Transistor, 50V/12A Switching Application
Company: Sanyo Semiconductor Corporation
Datasheet: Download 2SD1669 datasheet File size : 169 kB
Request For quote: Find where to buy 2SD1669
Datasheet text preview:
Ordering number:2092B
PNP/NPN Epitaxial Planar Silicon Transistors
2SB1136/2SD1669
50V/12A Switching Applications
Applications
· Relay drivers, high-speed inverters, converters, and other genral high-current switching applications.
Package Dimensions
unit:mm 2041A
[2SB1136/2SD1669]
Features
· Low-saturation collector-to-emitter voltage : VCE(sat)=0.5V (PNP), 0.4V (NPN) max. · Wide ASO leading to high resistance to breakdown. · Micaless package facilitating mounting.
( ) : 2SB1136
1 : Base 2 : Collector 3 : Emitter SANYO : TO-220ML
Specifications
Absolute Maximum Ratings at Ta = 25°C
Parameter Collector-to-Base Voltage Collector-to-Emitter Voltage Emitter-to-Base Voltage Collector Current Collector Current (Pulse) Collector Dissipation Junction Temperature Storage Temperature Symbol VCBO VCEO VEBO IC ICP PC Conditions
Ratings ()60 ()50 ()6 ()12 ()15 2
Unit V V V A A W W
Tc=25°C
Tj Tstg
30 150 55 to +150
°C °C
Electrical Characteristics at Ta = 25°C
Parameter Collector Cutoff Current Emitter Cutoff Current DC Current Gain Gain-Bandwidth Product Collector-to-Emitter Saturation Voltage Symbol ICBO IEBO hFE1 hFE2 fT VCE(sat) VCB=()40V, IE=0 VEB=()4V, IC=0 VCE=()2V, IC=()1A VCE=()2V, IC=()5A VCE=()5V, IC=()1A IC=()6A, IB=()0.6A 70* 30 10 ()0.4 MHz V Conditions Ratings min typ max ()0.1 ()0.1 280* Unit mA mA
* : The 2SB1136/2SD1669 are classified by 1A hFE as follows :
70 Q 140 100 R 200 140 S 280
Any and all SANYO products described or contained herein do not have specifications that can handle a p p l i c a t i o n s that require extremely high levels of reliability, s u c h as life-support systems, a i r c r a f t ' s c o n t r o l systems, o r other applications whose failure can be reasonably expected to result in serious p h y s i c a l and/or material damage. Consult with your SANYO representative nearest you before using a n y SANYO products described or contained herein in such applications. SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges,or other p a r a m e t e r s ) listed in products specifications of any and all SANYO products described or contained herein.
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquaters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
92098HA (KT)/10996TS (KOTO) 8-8812/4277AT, TS No.20921/4
2SB1136/2SD1669
Parameter Collector-to-Base Breakdown Voltage Collector-to-Emitter Breakdown Voltage Emitter-to-Base Breakdown Voltage Rise Time Storage Time Fall Time Symbol V(BR)CBO IC=()1mA, IE=0 V(BR)CEO IC=()1mA, RBE= V(BR)EBO ton tstg tf IE=()1mA, IC=0 See specified Test Circuti. See specified Test Circuit. See specified Test Circuit. Conditions Ratings min ()60 ()50 ()6 (0.2) 0.1 (0.4) 1.2 (0.1) 0.05 typ max Unit V V V µs µs µs µs µs µs
Switching Time Test Circuit
No.20922/4
2SB1136/2SD1669
No.20923/4
2SB1136/2SD1669
Specifications of any and all SANYO products described or contained herein stipulate the performance, characteristics, and functions of the described products in the independent state, and are not guarantees of the performance, characteristics, and functions of the described products as mounted in the customer's products or equipment. To verify symptoms and states that cannot be evaluated in an independent device, the customer should always evaluate and test devices mounted in the customer's products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all s e m i c o n d u c t o r products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. I n the event that any and all SANYO products described or contained herein fall under strategic products (including services) controlled under the Foreign Exchange and Foreign Trade Control Law of Japan, s u c h products must not be exported without obtaining export license from the Ministry of I n t e r n a t i o n a l Trade and Industry in accordance with the above law. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or m e c h a n i c a l , i n c l u d i n g photocopying and recording, o r any information storage or retrieval system, o r otherwise, w i t h o u t the prior written permission of SANYO Electric Co. , L t d . Any and all information described or contained herein are subject to change without notice due to product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification" for the SANYO product that you intend to use. I n f o r m a t i o n (including circuit diagrams and circuit parameters) herein is for example only ; i t is not g u a r a n t e e d for volume production. SANYO believes information herein is accurate and reliable, b u t no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties.
This catalog provides information as of September, 1998. Specifications and information herein are subject to change without notice.
PS No.20924/4
Others parts begin by 2s