Part: LM136ACSM4-5V
Category: Power Management -> Regulators -> Voltage Regulators
Description: Screening Options Available = ;; Package = LCC3 ;; Description = Voltage Regulator ;; Temperature Range = -55 to +150 C ;; Polarity = - ;; Current (A) = - ;; Input Voltage (V) = - ;; Output Voltage (V) = 5V ;; Voltage Drop (typ.) = - ;; Voltage Drop (max.) = -
Company: Semelab Plc
Datasheet: Download LM136ACSM4-5V datasheet File size : 41 kB
Request For quote: Find where to buy LM136ACSM4-5V
Datasheet text preview:
LM136CSM4 - 5V LM136ACSM4 - 5V
MECHANICAL DATA Dimensions in mm
5.59 ± 0.13 (0.22 ± 0.005) 0.25 ± 0.03 (0.01 ± 0.001) 1.40 ± 0.15 (0.055 ± 0.006)
0 . 6 4 ± 0.08 (0 . 0 2 5 ± 0.003)
0.23 r a d . (0.009) 3 2 1 .2 7 ± 0.05 (0 . 0 5 ± 0.002)
PRECISION 5V SHUNT REGULATOR DIODE IN A CERAMIC SURFACE MOUNT PACKAGE
0.23 min. (0.009)
3 . 8 1 ± 0.13 ( 0 .1 5 ± 0.005)
4
1
FEATURES
· Adjustable 4V to 6V · Low Temperature Coeficient
m · Wide Operating Current 600mA to 10mA
1.02 ± 0.20 (0.04 ± 0.008)
2.03 ± 0.20 (0.08 ± 0.008)
LCC3 HERMETICALLY SEALED CERAMIC SURFACE MOUNT PACKAGE
PIN 1 n/c PIN 2 V+ PIN 3 adj PIN 4 V-
· 0.6W Dynamic Impedance · ± 1% Inital Tolerance Available
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
IR IF Tcase TSTG Reverse Current Forward Current Operating Temperature Range Storage Temperature 15mA 10mA 55°C to +150°C 60°C to +150°C
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise stated)
Parameter Reverse Breakdown Voltage Reverse Breakdown Change with Current Reverse Dynamic Impedance Temperature StabilityNote 2 Adjusment Range Reverse Dynamic Impedance Long Term Stability IR =1mA TA = 25°C±0.1°C t =1000hrs IR =1mA TA = 25°C f = 100Hz VR Adjusted 5.00V 55°C £ TA £ +125°C IR =1mA IR =1mA TA = 25°C Test Conditions TA = 25°C IR =1mA LM136CSM4-5V LM136ACSM4-5V 600mA £ IR £ 10mA LM136CSM4-5V LM136ACSM4-5V Min. Typ. Max. 4.90 4.95 5.00 5.00 6 0.6 20 ±1 0.8 20 1.6 5.10 5.05 12 1.2 36 Units
V mV
W
mV V
W
ppm
Note 2. Temperature stability is guaranteed by design. Design limits are guaranteed (but not 100% function tested) over the indicated temperature and supply voltage ranges. These limits are not used to calculate outgoing quality levels. Stability is defined as the maximum change in Vxxx FROM 25°C to TA (MIN) or TA (MAX).
Semelab plc.
Telephone +44(0)1455) 556565. Fax +44(0)1455) 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim.5/99
Others parts begin by lm
LM-1 LM-2 LM-3 LM-4 LM-5 LM-6 LM-7 LM-8 LM-9 LM-10 LM-11 LM-12 LM-13 LM-14 LM-15 LM-16 LM-17 LM-18 LM-19 LM-20 LM-21 LM-22 LM-23 LM-24 LM-25 LM-26 LM-27 LM-28 LM-29 LM-30 LM-31 LM-32 LM-33 LM-34 LM-35 LM-36 LM-37 LM-38 LM-39 LM-40 LM-41 LM-42 LM-43 LM-44 LM-45 LM-46 LM-47 LM-48 LM-49 LM-50 LM-51 LM-52 LM-53 LM-54 LM-55 LM-56 LM-57 LM-58 LM-59 LM-60 LM-61 LM-62 LM-63 LM-64 LM-65
|
|
|