Details, datasheet, quote on part number:LM338V
| |
| Part: | LM338V |
| Category: | Power Management => Regulators => Voltage Regulators |
| Description: | Screening Options Available = ;; Package = TO247 ;; Description = Voltage Regulator ;; Temperature Range = 0 to +70 C ;; Polarity = Positive ;; Current (A) = 5.0A ;; Input Voltage (V) = 35V ;; Output Voltage (V) = Variable ;; Voltage Drop (typ.) = - ;; Voltage Drop (max.) = - |
| Company: | Semelab Plc |
| Datasheet: | Download LM338V datasheet File size : 58 kB |
| Request For quote: | Find where to buy LM338V
|
| |
Datasheet text preview:
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
!
1
2
5 AMP POSITIVE ADJUSTABLE VOLTAGE REGULATOR
3
Pin 1 ADJ. Pin 2 VOUT Case VIN
Pin 1 ADJ. Pin 2 VIN Case VOUT
FEATURES
· OUTPUT VOLTAGE RANGE OF 1.25 TO 35V · 1% OUTPUT VOLTAGE TOLERANCE (A VERSIONS) · 0.3% LOAD REGULATION · 0.01% / V LINE REGULATION · COMPLETE SERIES OF PROTECTIONS:
Q Package TO254
K Package TO3
1
2
3
· CURRENT LIMITING · THERMAL SHUTDOWN · SOA CONTROL
Pin 1 ADJ. Pin 2 VOUT Pin 3 VIN Case VOUT
V Package TO218
Order Information
Part Number IP138A IP138 LM138 IP338A IP338 LM338 KPack (TO3) VPack Q-Pack Temp. (TO218) (TO-254) Range -55 to +150°C " " 0 to 125°C " " Note: To order, add the package identifier to the part number. eg. IP138AQ
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VIO PD TJ TSTG TL Input - Output Differential Voltage Power Dissipation Operating Junction Temperature Range Storage Temperature Lead Temperature (Soldering, 10 sec.)
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
35V Internally limited See Table Above 65 to 150°C 300°C
Prelim. 4/96
Semelab plc.
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
Parameter
VREF Reference Voltage
Test Conditions
IOUT = 10mA IOUT = 10mA to 5A VIN VOUT = 3V to 35V P £ 50W TJ = 55 to +150°C
Min.
1.238 1.225
IP138A Typ.
1.25 1.250 0.005 0.020 5 0.1 20 0.3 0.002
Max.
1.262 1.270 0.010 0.040 15 0.3 30 0.6 0.010
Min.
LM138 IP138 Typ.
Max. Units
V
1.190
1.240 0.005 0.020 5 0.1 20 0.3 0.002 60
1.290 0.010 0.040 15 0.3 30 0.6 0.010
V
DVOUT Line Regulation 1 DVIN DVOUT Load Regulation 1 DIOUT
Thermal Regulation
VIN VOUT = 3V to 35V TJ = 55 to +150°C IOUT = 10mA to 5A IOUT = 10mA to 5A TJ = 55 to +150°C tp = 20ms CADJ = 0 VOUT = 10V f = 120Hz TJ = 55 to +150°C IOUT = 10mA to 5A VIN VOUT = 3V to 35V TJ = 55 to +150°C VIN VOUT = 35V TJ = 55 to +150°C VIN VOUT £ 10V DC 0.5ms Peak 5 7 0.25 TJ = 55 to +150°C VIN VOUT = 30V TJ = 55 to +150°C CADJ = 10mF TJ = 55 to +150°C 60 VOUT £ 5V VOUT ³ 5V VOUT £ 5V VOUT ³ 5V
%/V mV % mV % %/W dB dB
60 75 45 0.2 100 5 60
Ripple Rejection
75 45 0.2 100 5
IADJ
Adjust Pin Current
mA mA
mA A A %
DIADJ Adjust Pin Current
Change IMIN Minimum Load Current ISC Current Limit
3.5 8 12 1 1 t = 1000 Hrs 0.3 0.001
5 5 7
3.5 8 12 1
5
DVOUT Temperature DTEMP Stability DVOUT Long Term Stability DTIME
en RqJC RMS Output Noise (% of VOUT) Thermal Resistance Junction to Case
TJ = 55 to +150°C TA = 125°C f = 10 Hz to 10 kHz K Package (TO3)
2 1
1 0.3 0.001 1
% %
1
1
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package for the TO3 package. 2) Test Conditions unless othewise stated: VIN VOUT = 5V , TJ = 25°C , IOUT = 2.5A. Although power dissipation is internally limited, these specifications apply for dissipations of 50W and IMAX = 5A.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 4/96
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
Parameter
VREF Reference Voltage
Test Conditions
IOUT = 10mA IOUT = 10mA to 5A VIN VOUT = 3V to 35V P £ 50W TJ = 0 to +125°C
Min.
1.238 1.225
IP338A Typ.
1.25 1.250 0.005 0.020 5 0.1 20 0.3 0.002
Max.
1.262 1.270 0.010 0.040 15 0.3 30 0.6 0.020
Min.
LM338 IP338 Typ.
Max. Units
V
1.190
1.240 0.005 0.020 5 0.1 20 0.3 0.002 60
1.290 0.030 0.060 25 0.5 50 1 0.020
V
DVOUT Line Regulation 1 DVIN DVOUT Load Regulation 1 DIOUT
Thermal Regulation
VIN VOUT = 3V to 35V TJ = 0 to +125°C IOUT = 10mA to 5A IOUT = 10mA to 5A TJ = 0 to +125°C tp = 20ms CADJ = 0 VOUT = 10V f = 120Hz TJ = 0 to +125°C IOUT = 10mA to 5A VIN VOUT = 3V to 35V TJ = 0 to +125°C VIN VOUT = 35V TJ = 0 to +125°C VIN VOUT £ 10V DC 0.5ms Peak 5 6 0.25 TJ = 0 to +125°C VIN VOUT = 30V TJ = 0 to +125°C TA = 125°C f = 10 Hz to 10 kHz K Package (TO3) V Package (TO218) t = 1000 Hrs TJ = 0 to +125°C CADJ = 10mF TJ = 0 to +125°C 60 VOUT £ 5V VOUT ³ 5V VOUT £ 5V VOUT ³ 5V
%/V mV % mV % %/W dB dB
60 75 45 0.2 100 5 60
Ripple Rejection
75 45 0.2 100 5
IADJ
Adjust Pin Current
mA mA
mA A A %
DIADJ Adjust Pin Current
Change IMIN Minimum Load Current ISC Current Limit
3.5 8 12 1 1 0.3 0.001
10 5 6
3.5 8 12 1
10
DVOUT Temperature DTEMP Stability DVOUT Long Term Stability DTIME
en RqJC RMS Output Noise (% of VOUT) Thermal Resistance Junction to Case
2 1
1 0.3 0.003 1
% %
1 1
1 1
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package for the TO3 package and at the junction of the wide and narrow portion of the output lead for the TO218 package. 2) Test Conditions unless othewise stated: VIN VOUT = 5V , TJ = 25°C , IOUT = 2.5A. Although power dissipation is internally limited, these specifications apply for dissipations of 50W and IMAX = 5A.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 4/96
|
|