Part:LM338V
Category:Power Management => Regulators => Voltage Regulators
Description:Screening Options Available = ;; Package = TO247 ;; Description = Voltage Regulator ;; Temperature Range = 0 to +70 C ;; Polarity = Positive ;; Current (A) = 5.0A ;; Input Voltage (V) = 35V ;; Output Voltage (V) = Variable ;; Voltage Drop (typ.) = - ;; Voltage Drop (max.) = -
Company:Semelab Plc
Datasheet:Download LM338V datasheet   File size : 58 kB
Request For quote:  Find where to buy LM338V
 



Datasheet text preview:
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
!
1
2
5 AMP POSITIVE ADJUSTABLE VOLTAGE REGULATOR
3
Pin 1 ­ ADJ. Pin 2 ­ VOUT Case ­ VIN
Pin 1 ­ ADJ. Pin 2 ­ VIN Case ­ VOUT
FEATURES
· OUTPUT VOLTAGE RANGE OF 1.25 TO 35V · 1% OUTPUT VOLTAGE TOLERANCE (­A VERSIONS) · 0.3% LOAD REGULATION · 0.01% / V LINE REGULATION · COMPLETE SERIES OF PROTECTIONS:
Q Package ­ TO­254
K Package ­ TO­3
1
2
3
· CURRENT LIMITING · THERMAL SHUTDOWN · SOA CONTROL
Pin 1 ­ ADJ. Pin 2 ­ VOUT Pin 3 ­ VIN Case ­ VOUT
V Package ­ TO­218
Order Information
Part Number IP138A IP138 LM138 IP338A IP338 LM338 K­Pack (TO­3) V­Pack Q-Pack Temp. (TO­218) (TO-254) Range -55 to +150°C " " 0 to 125°C " " Note: To order, add the package identifier to the part number. eg. IP138AQ
ABSOLUTE MAXIMUM RATINGS (Tcase = 25°C unless otherwise stated)
VI­O PD TJ TSTG TL Input - Output Differential Voltage Power Dissipation Operating Junction Temperature Range Storage Temperature Lead Temperature (Soldering, 10 sec.)
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
35V Internally limited See Table Above ­65 to 150°C 300°C
Prelim. 4/96
Semelab plc.
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
Parameter
VREF Reference Voltage
Test Conditions
IOUT = 10mA IOUT = 10mA to 5A VIN ­ VOUT = 3V to 35V P £ 50W TJ = ­55 to +150°C
Min.
1.238 1.225
IP138A Typ.
1.25 1.250 0.005 0.020 5 0.1 20 0.3 0.002
Max.
1.262 1.270 0.010 0.040 15 0.3 30 0.6 0.010
Min.
LM138 IP138 Typ.
Max. Units
V
1.190
1.240 0.005 0.020 5 0.1 20 0.3 0.002 60
1.290 0.010 0.040 15 0.3 30 0.6 0.010
V
DVOUT Line Regulation 1 DVIN DVOUT Load Regulation 1 DIOUT
Thermal Regulation
VIN ­ VOUT = 3V to 35V TJ = ­55 to +150°C IOUT = 10mA to 5A IOUT = 10mA to 5A TJ = ­55 to +150°C tp = 20ms CADJ = 0 VOUT = 10V f = 120Hz TJ = ­55 to +150°C IOUT = 10mA to 5A VIN ­ VOUT = 3V to 35V TJ = ­55 to +150°C VIN ­ VOUT = 35V TJ = ­55 to +150°C VIN ­ VOUT £ 10V DC 0.5ms Peak 5 7 0.25 TJ = ­55 to +150°C VIN ­ VOUT = 30V TJ = ­55 to +150°C CADJ = 10mF TJ = ­55 to +150°C 60 VOUT £ 5V VOUT ³ 5V VOUT £ 5V VOUT ³ 5V
%/V mV % mV % %/W dB dB
60 75 45 0.2 100 5 60
Ripple Rejection
75 45 0.2 100 5
IADJ
Adjust Pin Current
mA mA
mA A A %
DIADJ Adjust Pin Current
Change IMIN Minimum Load Current ISC Current Limit
3.5 8 12 1 1 t = 1000 Hrs 0.3 0.001
5 5 7
3.5 8 12 1
5
DVOUT Temperature DTEMP Stability DVOUT Long Term Stability DTIME
en RqJC RMS Output Noise (% of VOUT) Thermal Resistance Junction to Case
TJ = ­55 to +150°C TA = 125°C f = 10 Hz to 10 kHz K Package (TO­3)
2 1
1 0.3 0.001 1
% %
1
1
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package for the TO­3 package. 2) Test Conditions unless othewise stated: VIN ­ VOUT = 5V , TJ = 25°C , IOUT = 2.5A. Although power dissipation is internally limited, these specifications apply for dissipations of 50W and IMAX = 5A.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 4/96
IP138A SERIES IP138A SERIES IP338A SERIES IP338A SERIES LM138 SERIES
Parameter
VREF Reference Voltage
Test Conditions
IOUT = 10mA IOUT = 10mA to 5A VIN ­ VOUT = 3V to 35V P £ 50W TJ = 0 to +125°C
Min.
1.238 1.225
IP338A Typ.
1.25 1.250 0.005 0.020 5 0.1 20 0.3 0.002
Max.
1.262 1.270 0.010 0.040 15 0.3 30 0.6 0.020
Min.
LM338 IP338 Typ.
Max. Units
V
1.190
1.240 0.005 0.020 5 0.1 20 0.3 0.002 60
1.290 0.030 0.060 25 0.5 50 1 0.020
V
DVOUT Line Regulation 1 DVIN DVOUT Load Regulation 1 DIOUT
Thermal Regulation
VIN ­ VOUT = 3V to 35V TJ = 0 to +125°C IOUT = 10mA to 5A IOUT = 10mA to 5A TJ = 0 to +125°C tp = 20ms CADJ = 0 VOUT = 10V f = 120Hz TJ = 0 to +125°C IOUT = 10mA to 5A VIN ­ VOUT = 3V to 35V TJ = 0 to +125°C VIN ­ VOUT = 35V TJ = 0 to +125°C VIN ­ VOUT £ 10V DC 0.5ms Peak 5 6 0.25 TJ = 0 to +125°C VIN ­ VOUT = 30V TJ = 0 to +125°C TA = 125°C f = 10 Hz to 10 kHz K Package (TO­3) V Package (TO­218) t = 1000 Hrs TJ = 0 to +125°C CADJ = 10mF TJ = 0 to +125°C 60 VOUT £ 5V VOUT ³ 5V VOUT £ 5V VOUT ³ 5V
%/V mV % mV % %/W dB dB
60 75 45 0.2 100 5 60
Ripple Rejection
75 45 0.2 100 5
IADJ
Adjust Pin Current
mA mA
mA A A %
DIADJ Adjust Pin Current
Change IMIN Minimum Load Current ISC Current Limit
3.5 8 12 1 1 0.3 0.001
10 5 6
3.5 8 12 1
10
DVOUT Temperature DTEMP Stability DVOUT Long Term Stability DTIME
en RqJC RMS Output Noise (% of VOUT) Thermal Resistance Junction to Case
2 1
1 0.3 0.003 1
% %
1 1
1 1
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package for the TO­3 package and at the junction of the wide and narrow portion of the output lead for the TO­218 package. 2) Test Conditions unless othewise stated: VIN ­ VOUT = 5V , TJ = 25°C , IOUT = 2.5A. Although power dissipation is internally limited, these specifications apply for dissipations of 50W and IMAX = 5A.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Prelim. 4/96