Part: D3F60
Category: Discrete -> Diodes & Rectifiers -> General Purpose Rectifiers
Description: General Purpose Rectifiers/ Single (Surface Mount)
Company: Shindengen America, Inc.
Datasheet: Download D3F60 datasheet File size : 216 kB
Request For quote: Find where to buy D3F60
Datasheet text preview:
SHINDENGEN
General Purpose Rectifiers
Single
D3F60
600V 3A
FEATURES High reliability with superior moisture resistance Applicable to Automatic Insertion APPLICATION Conventional Rectification Power source(Power Supply) Home Appliances, Office Equipment Telecommunication, Factory Automation
Case : 2F (Unit : mm)
RATINGS
Absolute Maximum Ratings (If not specified Tl=25) It em Symbol Condi tions T stg Storage Temperature Tj Operati ng Junction Temperature VRM M axi mum Reverse Voltage IO A verage Rectified Forward Current 50Hz sine wave, R-load Tl=80 I FSM Peak Surge Forward Current 50Hz sine wave, Non-repetitive 1 cycle peak value, Tj=25 Electrical Characteristics (If not specified It em Symbol VF Forward Voltage IR Reverse Current Æjl Æja T hermal Resistance Tl=25) Condi tions Rat i ngs -55`150 150 600 3 150 Rat i ngs M ax.1.05 M ax.10 M ax.23 M ax.80 M ax.115 Un i t V A A Un i t V ÊA /W
I F=3A, Pulse measurement VR=VRM , Pulse measurement juncti on to lead juncti on to ambient, On alumina substrate juncti on to ambient, On glass-epoxy substrate
Copyright & Copy;2000 Shindengen Electric Mfg.Co.Ltd
D3F60
Forward Voltage
10
Forward Current IF [A]
Tl=150°C [TYP] Tl=25 °C [TYP]
1
Pulse measurement per diode
0.1
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
Forward Voltage VF [V]
D3F60
5
Forward Power Dissipation
Forward Power Dissipation PF [W]
4
3
SIN
2
1
0
0
1
2
3
4
5
Average Rectified Forward Current IO [A]
Tj = 150°C Sine wave
D3F60
6
Derating Curve
Average Rectified Forward Current IO [A]
5
4 SIN
3
2
1
0
0
20
40
60
80
100
120
140
160
Lead Temperature Tl [°C]
Sine wave R-load
D3F60
250
Peak Surge Forward Capability
IFSM
10ms 10ms
1 cycle
200
Peak Surge Forward Current IFSM [A]
non-repetitive, sine wave, Tj=25 °C before surge current is applied
150
100
50
0
1
2
5
10
20
50
100
Number of Cycles [cycles]
Others parts begin by d3
|
|
|