Details, datasheet, quote on part number: S-8233ADFE/FT
PartS-8233ADFE/FT
CategoryPower Management => Battery Management => Battery Protection => Lithium-Ion Rechargeable Battery Protection
TitleLithium-Ion Rechargeable Battery Protection
DescriptionFunction = For 3-cell ;; Overcharge Detection Voltage (Accuracy) = 4.1-4.35 V (±50 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-2.7 V (±80 MV) ;; Overcurrent Detection Voltage 1 (Accuracy) = 0.15-0.5 V (±10%) ;; Overcharge Detection Delay Time = 1.0s (C=0.47 UF) ;; Package (Power Dissipation) = 14-pin Sop (400 MW) 16-pin Tssop (300 MW)
CompanySeiko Instruments
DatasheetDownload S-8233ADFE/FT datasheet
  

 

Features, Applications

The is a series of lithium-ion rechargeable battery protection ICs incorporating high-accuracy voltage detection circuits and delay circuits. It is suitable for a 3-serial-cell lithium-ion battery pack.

Features

(1) Internal high-accuracy voltage detection circuit Over charge detection voltage Over charge release voltage 0.05 V- step 0.05 V- step (The over charge release voltage can be selected within the range where a difference from over charge detection voltage 0.3 V) Over discharge detection voltage Over discharge release voltage 0.10 V- step V - step (The over discharge release voltage can be selected within the range where a difference from over discharge detection voltage to 1.0V) Over current detection voltage V10% 0.05 V-step High input-voltage device (absolute maximum rating: 26 V) Wide operating voltage range: 24 V The delay time for every detection can be set via an external capacitor. Three over current detection levels (protection for short-circuiting) Internal charge/discharge prohibition circuit via the control terminal The function for charging batteries from V is available. Low current consumption Operation Power-down (9) 14-pin SOP package 50 A max (+25 C) 0.1 A max (+25 C)

Applications

Model/Item Over charge detection voltage Over charge release voltage 4.100.10V 4.050.10V Over discharge detection voltage 2.300.08V 2.400.08V Over discharge release voltage 3.000.10V 2.700.10V Over current 0V battery detection voltage1 charging function 0.40V10% 0.30V10% Available

Last 2 digits shows package type. FE14pin SOP, FT16pin TSSOP Change in the detection voltage is available in products other than the above listed ones. Contact the SII Semiconductor Products Sales Department.

Battery 1 Over charge + - Battery 2 Over charge
Battery 2 Over charge + - Battery 3 Over charge

The delay time for over current detection 2 and 3 is fixed by an internal IC circuit. The delay time cannot be changed via an external capacitor.


 

Related products with the same datasheet
S-8233ACFE/FT
S-8233AEFE/FT
S-8233AFFE/FT
S-8233AGFE/FT
S-8233AIFE/FT
S-8233AJFE/FT
S-8233AKFE/FT
S-8233ALFE/FT
S-8233AMFE/FT
S-8233ASeries
Some Part number from the same manufacture Seiko Instruments
S-8233AEFE/FT Function = For 3-cell ;; Overcharge Detection Voltage (Accuracy) = 4.1-4.35 V (±50 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-2.7 V (±80 MV) ;; Overcurrent Detection Voltage 1 (Accuracy)
S-8233B Function = For 3-cell ;; Overcharge Detection Voltage (Accuracy) = 3.8-4.4 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-2.8 V (±80 MV) ;; Overcurrent Detection Voltage 1 (Accuracy)
S-8233C
S-8241 Function = For 1-cell ;; Overcharge Detection Voltage (Accuracy) = 3.9-4.4 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-3.0 V (±80 MV) ;; Overcurrent Detection Voltage 1 (Accuracy)
S-8242 Function = For 2-cell ;; Overcharge Detection Voltage (Accuracy) = 3.9-4.4 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-3.0 V (±50 MV) ;; Overcurrent Detection Voltage 1 (Accuracy)
S-8243A Function = For 3 Cells ;; Overcharge Detection Voltage (Accuracy) = 3.9 V to 4.4 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0 to 3.0 V (±80 MV) ;; Overcurrent Detection Voltage
S-8244 Function = For 1-4 Cell (Secondary Protection) ;; Overcharge Detection Voltage (Accuracy) = 3.7-4.5 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = - ;; Overcurrent Detection Voltage 1 (Accuracy)
S-8253A Function = For 2-cell ;; Overcharge Detection Voltage (Accuracy) = 3.9-4.4 V (±25 MV) ;; Overdischarge Detection Voltage (Accuracy) = 2.0-3.0 V (±80 MV) ;; Overcurrent Detection Voltage 1 (Accuracy)
 