74ACT541
OCTAL BUS BUFFER WITH 3 STATE OUTPUTS (NON INVERTED)
s s

s

s

s

s

s

s

s

H IGH SPEED: tPD = 4ns (TYP.) at VCC = 5V LOW POWER DISSIPATION: ICC = 4µA(MAX.) at TA=25°C C OMPATIBLE WITH TTL OUTPUTS VIH = 2V (MIN.), V IL = 0.8V (MAX.) 50 TRANSMISSION LINE DRIVING CAPABILITY SYMMETRICAL OUTPUT IMPEDANCE: |IOH| = IOL = 24mA (MIN) BALANCED PROPAGATION DELAYS: tPLH tPHL OPERATING VOLTAGE RANGE: VCC (OPR) = 4.5V to 5.5V PIN AND FUNCTION COMPATIBLE WITH 74 SERIES 541 IMPROVED LATCH-UP IMMUNITY

DIP

SOP

TSSOP

ORDER CODES
PACKAGE DIP SOP TSSOP TUBE 74ACT541B 74ACT541M T&R 74ACT541MTR 74ACT541TTR

DESCRIPTION The 74ACT541 is an advanced high-speed CMOS OCTAL BUS BUFFER (3-STATE) fabricated with sub-micron silicon gate and double-layer metal wiring C2MOS tecnology. The 3 STATE control gate operates as two input AND such that if either G1 and G2 are high, all eight outputs are in the high impedance state. In order to enhance PC board layout, the

74AC T541 offers a pinout having inputs and outputs on opposite sides of the package. This device is designed to interface directly High Speed CMOS systems with TTL, NMOS and CMOS output voltage levlels. All inputs and outputs are equipped with protection circuits against static discharge, giving them 2KV ESD immunity and transient excess voltage.

PIN CONNECTION AND IEC LOGIC SYMBOLS

April 2001

1/9

74ACT541
INPUT AND OUTPUT EQUIVALENT CIRCUIT PIN DESCRIPTION
PIN No 1, 19 2, 3, 4, 5, 6, 7, 8, 9 18, 17, 16, 15, 14, 13, 12, 11 10 20 SYMBOL G1, G2 A1 to A8 Y1 to Y8 NAME AND FUNCTION Output Enable Inputs Data Inputs Data Outputs

GND V CC

Ground (0V) Positive Supply Voltage

TRUTH TABLE
INPUTS G1 H X L L
X : Don't Care Z : High Impedance

OUTPUT An X X H L Yn Z Z H L

G2 X H L L

ABSOLUTE MAXIMUM RATINGS
Symbol V CC VI VO IIK IOK IO Tstg TL Supply Voltage DC Input Voltage DC Output Voltage DC Input Diode Current DC Output Diode Current DC Output Current Storage Temperature Lead Temperature (10 sec) Parameter Value -0.5 to +7 -0.5 to VCC + 0.5 -0.5 to VCC + 0.5 ± 20 ± 20 ± 50 ± 400 -65 to +150 300 Unit V V V mA mA mA mA °C °C

ICC or IGND DC VCC or Ground Current

Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these conditions is not implied.

RECOMMENDED OPERATING CONDITIONS
Symbol V CC VI VO Top dt/dv Supply Voltage Input Voltage Output Voltage Operating Temperature Input Rise and Fall Time VCC = 4.5 to 5.5V (note 1) Parameter Value 4.5 to 5.5 0 to VCC 0 to VCC -55 to 125 8 Unit V V V °C ns/V

1) VIN from 0.8V to 2.0V

2/9

74ACT541
DC SPECIFICATIONS
Test Condition Symbol Parameter VCC (V) 4.5 5.5 4.5 5.5 4.5 5.5 4.5 5.5 VOL Low Level Output Voltage 4.5 5.5 4.5 5.5 II IOZ Input Leakage Current High Impedance Output Leakege Current Max ICC/Input Quiescent Supply Current Dynamic Output Current (note 1, 2) 5.5 5.5 5.5 5.5 5.5 VO = 0.1 V or VCC-0.1V VO = 0.1 V or VCC-0.1V IO=-50 µA IO=-50 µA IO=-24 mA IO=-24 mA IO=50 µA IO=50 µA IO=24 mA IO=24 mA VI = VCC or GND VI = VIH or VIL VO = VCC or GND VI = VCC - 2.1V VI = VCC or GND VOLD = 1.65 V max VOHD = 3.85 V min 0.6 4 4.4 5.4 3.86 4.86 0.001 0.001 0.1 0.1 0.36 0.36 ± 0.1 ± 0.5 TA = 25°C Min. 2.0 2.0 Typ. 1.5 1.5 1.5 1.5 4.49 5.49 0.8 0.8 4.4 5.4 3.76 4.76 0.1 0.1 0.44 0.44 ±1 ±5 1.5 40 75 -75 Max. Value -40 to 85°C Min. 2.0 2.0 0.8 0.8 4.4 5.4 3.7 4.7 0.1 0.1 0.5 0.5 ±1 ±5 1.6 80 50 -50 µA µA mA µA mA mA V Max. -55 to 125°C Min. 2.0 2.0 0.8 0.8 V Max. V Unit

VIH VIL VOH

High Level Input Voltage Low Level Input Voltage High Level Output Voltage

ICCT ICC IOLD IOHD

1) Maximum test duration 2ms, one output loaded at time 2) Incident wave switching is guaranteed on transmission lines with impedances as low as 50

AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, RL = 500 , Input tr = tf = 3ns)
Test Condition Symbol Parameter VC C (V) 5.0(*) 5.0(*) 5.0(*) TA = 25°C Min. 1.5 1.5 1.5 Typ. 4.0 6.0 5.0 Max. 6.5 7.8 7.8 Value -40 to 85°C Min. 1.5 1.5 1.5 Max. 8.0 9.0 9.0 -55 to 125°C Min. 1.5 1.5 1.5 Max. 8.0 9.0 9.0 ns ns ns Unit

tPLH tPHL Propagation Delay Time tPZL tPZH Output Enable Time tPLZ tPHZ Output Disable Time
(*) Voltage range is 5.0V ± 0.5V

3/9

74ACT541
CA PACITIVE CHARACTERISTICS
Test Condition Symbol Parameter VCC (V) 5.0 5.0 5.0 fIN = 10MHz TA = 25°C Min. Typ. 4 8 22 Max. Value -40 to 85°C Min. Max. -55 to 125°C Min. Max. pF pF pF Unit

CIN CO U T CPD

Input Capacitance Output Capacitance Power Dissipation Capacitance (note 1)

1) CPD is defined as the value of the IC's internal equivalent capacitance which is calculated from the operating current consumption without load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. ICC(opr) = CPD x VCC x f IN + ICC/n (per circuit)

TEST CIRCUIT

TEST tPLH, tPHL tPZL, tPLZ tPZH, tPHZ
CL = 50pF or equivalent (includes jig and probe capacitance) RL = R1 = 500 or equivalent RT = ZOUT of pulse generator (typically 50)

SWITCH Open 2VCC Open

4/9

74ACT541
W AVEFORM 1: PROPAGATION DELAYS (f=1MHz; 50% duty cycle)

WAVEFORM 2: OUTPUT ENABLE AND DISABLE TIME (f=1MHz; 50% duty cycle)