Details, datasheet, quote on part number:GS-NT1+/AME2
| |
Datasheet text preview:
®
NT1+/AME2
Power Management Module for ISDN NT1+
Rev. 02
Type
Vi
Vo +/-40V
Po 4.5W 350mW 1.4W 1.6 W 950mW
PRODUCT VIEW
180FEATURES COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power Mode) AND RPM (Restricted Power Mode) CONDITIONS INPUT FILTER TO MEET EMC REQUIREMENTS 5 INSULATED MAIN OUTPUTS PEAK INPUT OVERVOLTAGE WITHSTANDING INPUT FUSE ON AC MAIN INPUT INPUTS TO OUTPUTS INSULATION AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE FOR NPM/RPM MODE INDICATION (EM SIGNAL & GREEN LED). 3mA OUTPUT SOURCE CURRENT AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE FOR U-INTERFACE DETECTION (RED LED). 3mA OUTPUT SOURCE CURRENT SAFETY COMPLIANCE ACCORDING TO EN60950 MECHANICAL 96x58x26.6 DIMENSIONS (LxWxH): ORDERING NUMBER: GS-NT1+/AME2 INTERNAL RELAY FUNCTION FOR Vo1 POLARITY REVERSE ANALOG OUTPUTS EMERGENCY CONDITION PROGRAMMABLE VIA EXTERNAL COMMAND, TTL COMPATIBLE, 1mA SINK CURRENT U-INTERFACE ACCORDING TO ETR 080 WITH EXTERNAL CAPACITOR = 2.2 uF S-INTERFACE ACCORDING TO ETS 300 012
April 2000
1/7
NT1+/AME2
DESCRIPTION The NT1+ Power Management Module is a comprehensive solution for ISDN-NT1 "Plus" (Network Termination Basic Access type Plus) equipment, combining both AC-DC and DC-DC functions. The NT1+ Power Management Module (NT1+ PMM) provide the NT1+ equipment with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the Normal Power Mode (NPM) and the Restricted Power Mode (RPM). This specific version has been designed to meet the Alcatel Microelectronics chip set requirements, in agreement with Alcatel Microelectronics. Connected to the main, Input 1 is the AC input power to the NT1+ PMM, source of the whole necessary power in normal operating mode, namely in NPM. Input 2 is the DC power source when in RPM, therefore to connect to the U-Interface. When the main is available (230 Vac in this version) NT1+ PMM operate in Normal Power Mode, therefore it supply +40V (output 1) to the S-Interface being the output power 4.5 W. This output is current limiter protected via foldback characteristic. Output 2 delivers 5V (up to 350mW), output 3 delivers -24V (up to 1400 mW), output 4 is 50V at 1600 mW. Output 5 is the 3.3V for the chip set, the output power is typically 950 mW. When the main is missing, the module remains active but only in Restricted Power Mode (RPM). The only power source in RPM is the Input 2, the U-Interface (Vi2). Therefore in RPM the following condition apply to output 1: output 1 reverses the voltage (it becomes -40V) and the maximum power Pout is reduced to 420 mW. Mainly depending on input power available from Vi2 "U-interface", the maximum power available at the other outputs (2,3,4,5) is necessarily reduced than in NPM. It's subject of variation as per local application and regulation. In RPM it is also possible to set a different "emergency condition" setting HIGH (3.3 V) the auxiliary input 3 (analog emergency input, Vin3). In this case, Pout1 is further limited to 25mW, voltage level being -40V. The following tables give you details of the various parameters in the 3 different operating
2/7
modes, namely NPM, RPM with Vi3 LOW, RPM with Vi3 HIGH. Availability of the input AC main is also acknowledged by a specific auxiliary output (out 6, "EM signal"), a TTL-compatible signal set HIGH (to logic level "1") when the main is available and LOW when the AC main is missing. The presence of the "U" is acknowledged by an other auxiliary output (out 7) that is HIGH only when Vin2 > 40V. The NT1+ PMM provides double insulation (3000 Vrms) between the inputs (1 and 2), and among the input 1 and all the outputs. Basic insulation exists among Out1 and all other outputs. The other outputs (including the 2 auxiliary outputs) and the input 3, share the same common ground. Double insulation (2000 Vrms) is provided among Input 2 (DC "U") and all outputs. The NT1+ Power Management Module operate in the range -10 to +70 oC, storage temperatures in the range -40 to +85 oC are allowed.
NT1+/AME2
ELECTRICAL CHARACTERISTICS when in NPM (Tamb=25oC, unless otherwise specified.) NPM Standard Condition: Vin1 = 180 to 264 Vrms Vin2 = 40 to 120 Vdc
Symbol Vi1 Vi2 fi Vi1st Pi1 Vi2st Vo1 Vo2 Vo3 Vo4 Vo5 Vo6 Vo7 Vor1,3,4 Vor2 Vor5 Po1 Po2 Po3 Po4 Po5 Vi1th Ttr Vi1pk Vi2pk Vo1pk Vis Vist th MTBF Top Tstg Parameter AC Input Voltage 1 DC Input Voltage 2 Vi1 Input Frequency Start up Input 1 voltage Input 1 Apparent Power Start up Input 2 voltage Output Voltage 1 Output Voltage 2 Output Voltage 3 Output Voltage 4 Output Voltage 5 Auxiliary Output 6 (EM) Auxiliary Output 7 (red LED) Output Ripple voltage 1,3,4 Output Ripple voltage 2 Output Ripple voltage 5 Output Power 1 Output Power 2 Output Power 3 Output Power 4 Output Power 5 NPM => threshold RPM mode any polarity Vi1 = 230 Vrms Output parameters Standard Condition as per NPM Test Condition Min. 180 40 43 Typ. Max. 264 120 56 175 15 48 34 4.75 -22 -47 3.15 2.7 2.7 40 5 -24 -50 3.3 42 5.25 -26 -55 3.45 3.5 3.5 100 30 30 4.5 350 1.4 1.6 950 160 5 2000 1000 250 Unit Vrms Vdc Hz Vrms VA Vdc V V V V V V V mVrms mVrms mVrms W mW W W mW Vrms ms V V V Vrms V ms Mh +70 +85
o o
NPM Standard Condition Output parameters as per Std. Condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition BW: 0-20 MHz Standard condition BW: 0-20 MHz Standard condition BW: 0-20 MHz Std. condition according to ETS300 012, E5.1.5, E5.1.6, E5.1.7 (n=4) Standard condition Standard condition During 1 s, 40% of the time during the ring period at the analog interface. The output is current limited at 2.5 mA +/- 0.2 mA, with 220uF capacitor Standard condition Vi1 Output parameters as per Standard Condition transition NPM => RPM and vice versa according to ETS300 012, E5.1.3 (n=4) t = 10/700 us as per 1TR9 Dec. 96 t = 10/700 us as per 1TR9 Dec. 96 t = 10/700 us as per 1TR9 Dec. 96
Transition time Input 1 Transient overvoltage Input 2 Transient overvoltage Output 1 Transient overvoltage Insulation Voltage Insulation Voltage Hold-up time Mean Time Before Failure Oper. Ambient Temperature Storage Temperature Range
Input 1 to outputs and input 1 to input 2, t=60s reinforced insulation as per 3000 EN60950 Input 1 to outputs t=10/700 us (pulse) Vin = 180 Vrms Standard Condition Ground Fixed, MIL-HDBK-217E 4000 20 1 -10 -40
C C
3/7
|
|