Datasheet text preview:
®
NT1+/UR2
Power Management Module for ISDN NT1+
Rev. 03
Type
Vi
Vo +/-40V
Po 4.5W 720mW 900mW 100mW 700mW
PRODUCT VIEW
180+5V -21V -50V -150V
FEATURES COMBINED AC+DC CONVERTER FOR ISDN NT1+ APPLICATION Uo INTERFACE (DC) AND MAIN (AC) INPUTS TO ENABLE NPM (Normal Power Mode) AND RPM (Restricted Power Mode) CONDITIONS INPUT FILTER TO MEET EMC REQUIREMENTS 5 INSULATED MAIN OUTPUTS PEAK INPUT OVERVOLTAGE WITHSTANDING INPUT FUSE ON AC MAIN INPUT INPUTS TO OUTPUTS INSULATION AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE FOR NPM/RPM MODE INDICATION (EM SIGNAL & GREEN LED). 3mA OUTPUT SOURCE CURRENT AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE FOR U-INTERFACE DETECTION (RED LED). 3mA OUTPUT SOURCE CURRENT ORDERING NUMBER: GS-NT1+/UR2 AUXILIARY LOGIC OUTPUT TTL-COMPATIBLE FOR AUTO SETTING TO ISDN OR ANALOG PHONE CONNECTION TO U-INTERFACE (RELAY). 3mA OUTPUT SOURCE CURRENT INTERNAL RELAY FUNCTION FOR Vo1 POLARITY REVERSE ANALOG OUTPUTS EMERGENCY CONDITION PROGRAMMABLE VIA EXTERNAL COMMAND, TTL COMPATIBLE, 1mA SINK CURRENT U-INTERFACE ACCORDING TO ETR 080 WITH EXTERNAL CAPACITOR January 2001
1/7
NT1+/UR2
DESCRIPTION The NT1+/UR2 Power Management Module is a comprehensive solution for ISDN-NT1 "Plus" (Network Termination Basic Access type Plus) equipment, combining both AC-DC and DC-DC functions. The NT1+ Power Management Module (NT1+ PMM) provide the NT1+ equipment with all necessary supply voltages as well as control signals to operate in the different operating modes, typically the Normal Power Mode (NPM) and the Restricted Power Mode (RPM). Connected to the main, Input 1 is the AC input power to the NT1+ PMM, source of the whole necessary power in normal operating mode, namely in NPM. Input 2 is the DC power source when in RPM, therefore to connect to the U-Interface. When the main is available (230 Vac in this version) NT1+ PMM operate in Normal Power Mode, therefore it supply +40V (output 1) to the S-Interface being the output power 4.5 W. Output 2 delivers 5V (up to 720mW) for the logics and output 3 delivers -21V (up to 900 mW). Out voltage 4 is -50V with 100 mW output power. Last, output 5 delivers -150V and the output power can reach peaks of 700 mW. When the main is missing, the module remains active but only in Restricted Power Mode (RPM). The only power source in RPM is the Input 2, the U-Interface (Vi2). Therefore in RPM the following condition apply to outputs 1 and 2: output 1 reverses the voltage (it becomes -40V) and the maximum power Pout is reduced to 420 mW. P2max is reduced to 450 mW typically, however the output power available at outputs 2,3,4,5 mainly depend on input power available from the "U Interface" Vi2, therefore subject of variation as per local application and regulation. In RPM it is also possible to set a different "emergency condition" setting HIGH the auxiliary input 3 (analog emergency input, Vin3). In this case Pout1 is reduced to 25mW, voltage level being -40V. The following tables give you details of the various parameters in the 3 different operating modes, namely NPM, RPM with Vi3 LOW, RPM with Vi3 HIGH. Availability of the input AC main is also acknowledged by a specific auxiliary output (out 6, "EM signal"), a TTL-compatible signal set HIGH (to logic level "1") when the main is available and LOW when the AC main is missing. An auxiliary output (Output RELAY, pin 11) is available for U-INTERFACE voltage level acknowledge, the threshold level being fixed at 85 V. When U-INTERFACE voltage level is below 85 V, a POTS is connected therefore the auxiliary relay output is LOW. Vice versa, this output goes HIGH when U is higher than 85V (ISDN line card). The presence of the "U" is detected by an other auxiliary output (out 7) that is HIGH only when Vin2 >34V. The NT1+ PMM provides double insulation (3000 Vrms) between the inputs (1 and 2), and among the input 1 and all the outputs. Basic insulation exists among Out1 and all other outputs. The other outputs (including the 2 auxiliary outputs) and the input 3, share the same common ground. Double insulation (2000 Vrms) is provided among Input 2 (DC "U") and all outputs. The NT1+ Power Management Module operate in the range -10 to +70 oC, storage temperatures in the range -40 to +85 oC are allowed.
2/7
NT1+/UR2
ELECTRICAL CHARACTERISTICS when in NPM (Tamb=25oC, unless otherwise specified.) NPM Standard Condition: Vin1 = 180 to 264 Vrms Vin2 = 40 to 120 Vdc
Symbol Vi1 Vi2 fi Vi1st Pi1 Vi2nd Vo1 Vo2 Vo3 Vo4 Vo5 Vo6 Vo7 Vor1,3,4,5 Vor2 Po1 Po2 Po3 Po4 Po5 Vi1th Ttr Vi1pk Vi1pk Vi1pk Vo1pk Vis Vist th MTBF Top Parameter AC Input Voltage 1 DC Input Voltage 2 Vi1 Input Frequency Start up Input 1 voltage Input 1 Apparent Power Start up Input 2 voltage Output Voltage 1 Output Voltage 2 Output Voltage 3 Output Voltage 4 Output Voltage 5 Auxiliary Output 6 (EM) Auxiliary Output 7 (red LED) Output Ripple voltage 1,3,4,5 Output Ripple voltage 2 Output Power 1 Output Power 2 Output Power 3 Output Power 4 Output Power 5 NPM => threshold RPM mode any polarity Vi1 = 230 Vrms Output parameters Standard Condition as per NPM Test Condition Min. 180 40 43 Typ. Max. 264 120 56 175 15 40 34 4.75 -20 -48 -140 3.75 3.75 40 5 -21 -50 -150 5 5 42 5.25 -24 -65 -170 5.25 5.25 100 30 4.5 720 900 100 700 160 5 2000 to 2500 Unit Vrms Vdc Hz Vrms VA Vdc V V V V V V V mVrms mVrms W mW mW mW mW Vrms ms V V V V V V ms Mh +70
o
NPM Standard Condition Output parameters as per Std. Condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition Standard condition BW: 0-20 MHz Standard condition BW: 0-20 MHz Std. condition according to ETS300 012, E5.1.5, E5.1.6, E5.1.7 (n=4) Standard condition Standard condition Standard condition The output is current limited at 3 mA +/0.2 mA, with 100uF capacitor Vi1 Output parameters as per Standard Condition transition NPM => RPM and vice versa according to ETS300 012, E5.1.3 (n=4) t = 10/700 us as per 1TR9 Dec. 96 common mode test ETS300 047-5p5.6 according
Transition time Input 1 Transient overvoltage Input 1 Transient overvoltage Input 1 Transient overvoltage Output 1 Transient overvoltage Insulation Voltage Insulation Voltage Hold-up time Mean Time Before Failure Oper. Ambient Temperature
impuls transfer from main acording to 2500 ETS300 047-5p5.7.1 t = 1,2/50 us 500
Input 1 to outputs and input 1 to input 2, t=60s reinforced insulation as per 3000 EN60950 Input 1 to outputs t=10/700 us (pulse) Vin = 180 Vrms Standard Condition Ground Fixed, MIL-HDBK-217E 4000 20 1 -10
C