Digchip : Database on electronics components
 
Member, Distributor  
Log In
Email:
Password:


Part: 74ACT11014

Category:
 Logic
   -> Buffers/Inverters
     -> 2-State
             -> CMOS/BiCMOS->AC/ACT Family

Description: Hex Schmitt-trigger Inverter

Company: Texas Instruments, Inc.

Datasheet: Download 74ACT11014 datasheet     File size : 275 kB

Request For quote: Find where to buy 74ACT11014



Datasheet text preview:
74ACT11014 HEX SCHMITT-TRIGGER INVERTER
SCAS142B ­ FEBRUARY 1991 ­ REVISED AUGUST 1995

D D D D D D

Inputs Are TTL-Voltage Compatible Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise EPIC TM (Enhanced-Performance Implanted CMOS) 1-µm Process 500-mA Typical Latch-Up Immunity at 125°C Package Options Include Plastic Small-Outline (D) and Standard Plastic 300-mil DIP (J) Packages

DW OR N PACKAGE (TOP VIEW)

1Y 2Y 3Y GND GND GND GND 4Y 5Y 6Y

1 2 3 4 5 6 7 8 9 10

20 19 18 17 16 15 14 13 12 11

1A 2A 3A NC VCC VCC NC 4A 5A 6A

description
The 74ACT11014 contains six independent inverters. The device performs the Boolean function Y = A. Because of the Schmitt action, the device has different input threshold levels for positive-going (VT+) and negative-going (VT­) signals. The 74ACT11014 is temperature compensated and can be triggered from the slowest of input ramps and still give clean, jitter-free output signals. It also has a greater noise margin than conventional inverters. The 74ACT11014 is characterized for operation from ­ 40°C to 85°C.
FUNCTION TABLE (each inverter) INPUT A H L OUTPUT Y L H

logic symbol
1A 2A 3A 4A 5A 6A 20 19 18 13 12 11 1 2 3 8 9 10 1Y 2Y 3Y 4Y 5Y 6Y

logic diagram, each inverter (positive logic)
A Y

This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.

Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.

Copyright © 1995, Texas Instruments Incorporated

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

1

74ACT11014 HEX SCHMITT-TRIGGER INVERTER
SCAS142B ­ FEBRUARY 1991 ­ REVISED AUGUST 1995

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ­ 65°C to 150°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.

recommended operating conditions (see Note 2)
MIN VCC VIH VIL VI VO IOH IOL TA Supply voltage High-level input voltage Low-level input voltage Input voltage Output voltage High-level output current Low-level output current Operating free-air temperature ­ 40 0 0 4.5 2 0.8 VCC VCC ­ 24 24 85 NOM 5 MAX 5.5 UNIT V V V V V mA mA °C

NOTE 2: Unused inputs must be held high or low to prevent them from floating.

2

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

74ACT11014 HEX SCHMITT-TRIGGER INVERTER
SCAS142B ­ FEBRUARY 1991 ­ REVISED AUGUST 1995

electrical characteristics over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER VT+ Positive-going threshold VT­ Negative-going threshold VT Hysteresis (VT+ ­ VT­ IOH = ­ 50 µA µA VOH IOH = ­ 24 mA mA IOH = ­ 75 mA IOL = 50 µA 50 µA VOL IOL = 24 mA 24 mA IOL = 75 mA VI = VCC or GND VI = VCC or GND, One input at 3.4 V, IO = 0 Other inputs at VCC or GND TEST CONDITIONS CONDITIONS VCC 4.5 V 5.5 V 4.5 V 5.5 V 4.5 V 5.5 V 4.5 V 5.5 V 4.5 V 5.5 V 5.5 V 4.5 V 5.5 V 4.5 V 5.5 V 5.5 V 5.5 V 5.5 V 5.5 V ± 0.1 4 0.9 0.1 0.1 0.36 0.36 0.4 0.4 4.4 5.4 3.94 4.94 MIN TA = 25°C TYP MAX 2 2 0.8 0.8 1.2 1.2 0.4 0.4 4.4 5.4 3.8 4.8 3.85 0.1 0.1 0.44 0.44 1.65 ±1 40 1 µA µA mA pF V V MIN MAX 2 V 2 0.8 V 0.8 1.2 V 1.2 UNIT

II ICC ICC

Ci VI = VCC or GND 5V 5 Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC.

switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER tPLH tPHL FROM (INPUT) A TO (OUTPUT) Y MIN 2.3 3.3 TA = 25°C TYP MAX 5.6 6.4 8.4 8.3 MIN 2.3 3.3 MAX 9.2 9.5 UNIT ns

operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER Cpd Power dissipation capacitance TEST CONDITIONS No Load, f = 1 MHz TYP 30 UNIT pF

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

3

74ACT11014 HEX SCHMITT-TRIGGER INVERTER
SCAS142B ­ FEBRUARY 1991 ­ REVISED AUGUST 1995

PARAMETER MEASUREMENT INFORMATION
From Output Under Test CL = 50 pF (see Note A) 500 Output Input (see Note B) tPHL 3V 1.5 V 1.5 V 0V tPLH VOH 50% VCC VOL LOAD CIRCUIT VOLTAGE WAVEFORMS

50% VCC

NOTES: A. CL includes probe and jig capacitance. B. Input pulses are supplied by generators having the following characteristics: PRR 10 MHz, ZO = 50 , tr = 3 ns, tf = 3 ns. C. The outputs are measured one at a time with one input transition per measurement.

Figure 1. Load Circuit and Voltage Waveforms

4

POST OFFICE BOX 655303

· DALLAS, TEXAS 75265

IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK. In order to minimize risks associated with the customer's applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI's publication of information regarding any third party's products or services does not constitute TI's approval, warranty or endorsement thereof.

Copyright © 1998, Texas Instruments Incorporated




Others parts begin by 74
74-1   74-2   74-3   74-4   74-5   74-6   74-7   74-8   74-9   74-10   74-11   74-12   74-13   74-14   74-15   74-16   74-17   74-18   74-19   74-20   74-21   74-22   74-23   74-24   74-25   74-26   74-27   74-28   74-29   74-30   74-31   74-32   74-33   74-34   74-35   74-36   74-37   74-38   74-39   74-40   74-41   74-42   74-43   74-44   74-45   74-46   74-47   74-48   74-49   74-50   74-51   74-52   74-53   74-54   74-55   74-56   74-57   74-58   74-59   74-60   74-61   74-62